{"product_id":"lxd63b600l-siemens-3-pole-600-amp-600v-circuit-breaker","title":"LXD63B600L | Siemens 3 Pole 600 Amp 600v Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Siemens LXD63B600L is a high-performance Sentron Series molded case circuit breaker (MCCB) engineered for demanding electrical protection in industrial and commercial applications. Rated for 600 Amps, this 3-pole breaker operates at 600 Volts AC and features a thermal-magnetic trip unit for long-time and instantaneous overcurrent protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 592.562px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 51.7875px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 22.3814%; text-align: left; height: 51.7875px;\"\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eCondition\u003c\/p\u003e\n\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 77.2882%; height: 51.7875px;\"\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eNew\/Never Used Surplus\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 29.2125px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 22.3814%; text-align: left; height: 29.2125px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 77.2882%; height: 29.2125px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSiemens\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.625px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 21.625px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 21.625px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\u003cspan\u003eCircuit Protection\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 19.6px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 19.6px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eLXD63B600L\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 49.125px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 22.3814%; text-align: left; height: 49.125px;\"\u003eSubcatecory\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 77.2882%; height: 49.125px;\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem]  md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003cdiv class=\"flex gap-[1.75rem]  md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem]  md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003eMolded Case Circuit Breakers (MCCB)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 39.2px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eFamily\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 39.2px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eSentron Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.8125px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 40.8125px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 40.8125px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eLXD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.8125px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 41.8125px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 41.8125px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan\u003e600V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.8px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 58.8px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eAmperage Rating\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 58.8px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan\u003e600A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 39.2px;\"\u003eInterrupting Capacity\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 39.2px;\"\u003e\u003cspan\u003e35kA at 480V, 25kA at 600V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 39.2px;\"\u003ePhase \/ Poles\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 39.2px;\"\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e3 Phase \/ 3 Poles\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 39.2px;\"\u003eFrame Type\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 39.2px;\"\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eLD Frame\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.3875px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 41.3875px;\"\u003eTrip Type\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 41.3875px;\"\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThermal-Magnetic, LI Protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 42.4px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 42.4px;\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 42.4px;\"\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eFeed-Thru\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.3814%; text-align: left; height: 39.2px;\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd style=\"width: 77.2882%; height: 39.2px;\"\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003e7.5 x 11 x 4 in\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eLXD63B600L\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"929\" data-start=\"522\"\u003eThe LXD63B600L is part of the LD Frame family, equipped with standard breaking capacity and a non-interchangeable trip unit, ensuring precise and consistent performance in high-current environments. Designed to comply with UL 489 and IEC 60947-2 safety standards, this breaker provides enhanced system protection with interrupting capacities of 25kA at 600V and 35kA at 480V.\u003c\/p\u003e\n\u003cp data-end=\"1365\" data-start=\"1344\"\u003e\u003cstrong data-end=\"1365\" data-start=\"1348\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1825\" data-start=\"1366\"\u003e\n\u003cli class=\"\" data-end=\"1459\" data-start=\"1366\"\u003e\n\u003cp class=\"\" data-end=\"1459\" data-start=\"1368\"\u003eHigh Interrupting Capacity: 35 kA at 480V, 25 kA at 600V for superior fault protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1554\" data-start=\"1460\"\u003e\n\u003cp class=\"\" data-end=\"1554\" data-start=\"1462\"\u003eThermal-Magnetic Trip Unit: Provides long-time and instantaneous overcurrent protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1665\" data-start=\"1555\"\u003e\n\u003cp class=\"\" data-end=\"1665\" data-start=\"1557\"\u003eDurable LD Frame Design: Rugged construction for industrial applications with standard 40°C calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1731\" data-start=\"1666\"\u003e\n\u003cp class=\"\" data-end=\"1731\" data-start=\"1668\"\u003eCompliant and Safe: Meets UL 489 and IEC 60947-2 standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1825\" data-start=\"1732\"\u003e\n\u003cp class=\"\" data-end=\"1825\" data-start=\"1734\"\u003eVersatile Wiring Options: Includes TA2J6500 lugs for a wide copper\/aluminum wire range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"\" data-end=\"1968\" data-start=\"1827\"\u003eThe LXD63B600L is engineered to deliver reliable protection and performance across a range of industrial circuit protection applications.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105473077504,"sku":"LXD63B600L","price":3516.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l960_4e629b52-c0d8-47e6-8fb0-afb9eb9368ad.webp?v=1785547721","url":"https:\/\/alotechparts.com\/products\/lxd63b600l-siemens-3-pole-600-amp-600v-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}