{"product_id":"lib-200a-notifier-loop-interface-board","title":"LIB-200A | Notifier Loop Interface Board","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe LIB‑200A is a loop interface board manufactured by Honeywell Notifier, designed to integrate intelligent and addressable modules and XP Transponders into Notifier fire alarm control systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 264.8px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 66.7957%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 66.7957%; height: 19.6px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eNotifier\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 66.7957%; height: 19.6px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eDrives\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.7957%; height: 19.6px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eLIB-200A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.7957%; height: 19.6px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eControl\/Interface Board\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003eDevice Type\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 66.7957%; height: 19.6px;\"\u003eControl Unit Component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003eCompatibility\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 66.7957%; height: 19.6px;\"\u003eAM2020 and AFP1010 Fire Alarm Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003eCommunication Type\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 66.7957%; height: 19.6px;\"\u003eAddressable loop interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003eApplication\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 66.7957%; height: 19.6px;\"\u003eExpansion of intelligent modules and XP transponders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003eNetwork Type\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 66.7957%; height: 19.6px;\"\u003eResistive Network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 66.7957%; height: 19.6px;\"\u003ePanel or chassis-mounted (varies by system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003eIndicators\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 66.7957%; height: 19.6px;\"\u003eLikely LED indicators for diagnostic status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 33.0348%; text-align: left; height: 19.6px;\"\u003e\u003cspan\u003eWeight \u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.7957%; height: 19.6px;\"\u003e\u003cspan\u003e0.55 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003cth style=\"width: 33.0348%; text-align: left; height: 10px;\"\u003e\u003cspan\u003eReplacement Number\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.7957%; height: 10px;\"\u003e60396\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About LIB-200A\u003c\/h4\u003e\n\u003cp\u003eThe LIB-200A is part of Notifier’s legacy fire alarm control infrastructure, developed to support loop communication in the AM2020 and AFP1010 intelligent addressable systems. This Loop Interface Board acts as a bridge between the control panel and field devices such as intelligent modules and XP transponders, enabling precise communication across a resistive addressable loop. It ensures compatibility with Notifier’s proprietary protocols while maintaining robust integration in large-scale fire safety networks. Though discontinued, the LIB-200A remains a critical component in many installed systems and is often sourced for legacy system maintenance.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLoop Interface for Addressable Systems: Provides communication between the fire alarm panel and addressable field devices via a dedicated loop.\u003c\/li\u003e\n\u003cli\u003eCompatible with AM2020 and AFP1010: Specifically designed for integration into Notifier’s AM2020 and AFP1010 control panels, ensuring seamless expansion and communication.\u003c\/li\u003e\n\u003cli\u003eSupport for XP Transponders and Intelligent Modules: Enables control panels to interact with distributed devices and loop-powered transponders in complex fire protection networks.\u003c\/li\u003e\n\u003cli\u003eResistive Network Configuration: Operates on a resistive loop network, supporting robust signal transmission and field wiring architecture.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Indicators: Equipped with LED status indicators (varies by version) to assist with maintenance and system diagnostics.\u003c\/li\u003e\n\u003cli\u003eModular Control Unit Design: Installs directly into the control panel chassis as an internal board, simplifying integration and system expansion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe LIB-200A Loop Interface Board remains a vital component in Notifier’s legacy fire alarm ecosystem. Its ability to manage communication over addressable loops and support intelligent devices made it a cornerstone of AM2020 and AFP1010 panel architectures. For facilities relying on these older platforms, the LIB-200A continues to deliver dependable loop integration and system performance.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105300160768,"sku":"LIB-200A","price":285.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/54075972_540x_1d36a117-78a0-48dc-8adb-5dcbe1a919f2.jpg?v=1785544440","url":"https:\/\/alotechparts.com\/products\/lib-200a-notifier-loop-interface-board","provider":"Alo Tech Solutions","version":"1.0","type":"link"}