{"product_id":"kdm-2-notifier-keypad-display-module-for-nfs-640-80-character-backlit-display","title":"KDM-2 | Notifier Keypad Display Module for NFS-640 80-Character Backlit Display","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier KDM-2 is a keypad display module designed for programming and local control of the NFS-640 fire alarm control panel. It provides an 80-character backlit display and is required for each stand-alone system configuration.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 274.313px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003eKDM-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003eKeypad Display Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003eNotifier NFS-640 FACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003e80-character backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003eField programming and system display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003eRequires top row of cabinet; mounts in panel or network node\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003eLocal node display when at least one NCA or NCS is present on network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eRequirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003eOne KDM-2 required for each stand-alone 80-character display system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003ePanel-mount module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003e3.00 × 12.00 × 14.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 17.259%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82.3774%; height: 19.5938px;\"\u003e2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eKDM-2\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe KDM-2 is a dedicated keypad display module built for use with the Notifier NFS-640 intelligent fire alarm control panel. It enables local programming and monitoring with a clear, 80-character backlit display, ensuring operators have direct access to system status and configuration. The KDM-2 is mandatory for stand-alone 80-character display configurations and may also be installed in network nodes for local display of node-specific information. Designed for top-row cabinet mounting, it provides essential visibility and control within Notifier fire alarm networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated Keypad Module: Provides field programming and monitoring functions for NFS-640 systems.\u003c\/li\u003e\n\u003cli\u003eLarge Backlit Display: 80-character LCD ensures clear visibility in various lighting conditions.\u003c\/li\u003e\n\u003cli\u003eStand-Alone Requirement: One KDM-2 is required for each independent 80-character display system.\u003c\/li\u003e\n\u003cli\u003eNetwork Node Compatibility: Can be installed in nodes to display local information when an NCA or NCS is present for system-wide display.\u003c\/li\u003e\n\u003cli\u003ePanel-Mount Construction: Designed for installation in the top row of the cabinet.\u003c\/li\u003e\n\u003cli\u003eLocal Control Access: Provides immediate access to system information and configuration at the panel level.\u003c\/li\u003e\n\u003cli\u003eRugged and Reliable: Built to Notifier standards for long-term fire alarm system operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe KDM-2 delivers the reliability and precision required for programming and local display in Notifier NFS-640 fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105188225280,"sku":"KDM-2","price":1064.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_0a4753ea-0c6b-4327-96d1-1c8e720a6cce.webp?v=1785542183","url":"https:\/\/alotechparts.com\/products\/kdm-2-notifier-keypad-display-module-for-nfs-640-80-character-backlit-display","provider":"Alo Tech Solutions","version":"1.0","type":"link"}