{"product_id":"kal26100-square-d-100a-2-pole-600vac250vdc-thermal-magnetic-molded-case-circuit-breaker","title":"KAL26100 | Square D 100A 2-Pole 600VAC\/250VDC Thermal Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Square D KAL26100 is a 2-pole thermal magnetic molded case circuit breaker designed for dependable circuit protection in commercial and industrial applications. With a current rating of 100 amps and a voltage rating of 600VAC\/250VDC, it provides reliable overload and short-circuit protection. The KAL26100 features a feed-thru connection and a high interrupting rating of 25kAIC at 480V, ensuring robust performance in demanding electrical systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 450.816px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eSquare D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eKAL26100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eKAL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eK-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003e600VAC \/ 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003e25kAIC @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eSingle Phase (1PH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eFeed-Thru (Lugs on Both Ends)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003e#4 AWG–350 kcmil (Cu\/Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eIndividual \/ Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eUL 489, CSA C22.2, IEC 60947-2, Federal W-C-375B\/GEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003e40°C (104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003e8\" x 4.5\" x 4.75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 29.7435%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.9847%; height: 19.6007px;\"\u003e8 lb (3.63 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eKAL26100\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"590\" data-end=\"1074\" class=\"\"\u003eThe KAL26100 is part of Square D’s KAL Series of molded case circuit breakers, known for their rugged design and precision trip characteristics. Built with a K-Frame structure, this breaker offers enhanced mechanical durability and consistent thermal magnetic performance. It includes both long-time and instantaneous trip functions to protect circuits from sustained overloads and short-circuit faults. The breaker supports both AC and DC operation, making it suitable for industrial power distribution systems and heavy-duty control panels where versatility and safety compliance are critical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated at 25kAIC at 480V for reliable fault current interruption.\u003c\/li\u003e\n\u003cli\u003eDual Voltage Compatibility: Operates at 600VAC and 250VDC for flexible system integration.\u003c\/li\u003e\n\u003cli\u003eThermal Magnetic Trip Unit: Provides both overload and short-circuit protection for stable performance.\u003c\/li\u003e\n\u003cli\u003eFeed-Thru Connection Type: Allows secure and efficient wiring for line and load circuits.\u003c\/li\u003e\n\u003cli\u003eRugged K-Frame Construction: Engineered for durability and consistent performance under high electrical stress.\u003c\/li\u003e\n\u003cli\u003eUL, CSA, and IEC Certified: Meets global safety and performance standards for industrial applications.\u003c\/li\u003e\n\u003cli\u003eWide Wire Range: Accommodates #4 AWG to 350 kcmil conductors for flexible installation.\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Rated (40°C): Ensures reliable operation in standard industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe KAL26100 delivers the reliability and precision required for industrial power distribution and protection systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":49105079664896,"sku":"KAL26100","price":2791.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-11-12_20.04.27.png?v=1785539632","url":"https:\/\/alotechparts.com\/products\/kal26100-square-d-100a-2-pole-600vac250vdc-thermal-magnetic-molded-case-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}