{"product_id":"juniper-qfx5200-32c-safi-switch","title":"Juniper QFX5200-32C-SAFI Switch","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eQFX5200 with SONiC, 32 x QSFP+\/QSFP28 ports, redundant fans, 2 x AC power supplies, back-to-front airflow\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\n[properties]\n\u003ctable width=\"571\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProperties\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003eJuniper QFX5200-32C-SAFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eDescription\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003eQFX5200 (hardware only; software services sold separately), with SONiC, 32 x QSFP+\/QSFP28 ports, redundant fans, 2 x AC power supplies, back-to-front airflow.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eQFX5200 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eIncluded\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSONiC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e17.36 x 1.72 x 20.48 in. (44.09 x 4.37 x 52.02 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eRack units\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e1 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e23.8 lb (10.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"571\" data-mce-fragment=\"1\"\u003eDeployment Options for QFX5200-32C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e32x100GbE\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003eSpine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e128x25GbE\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003eLeaf\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e64x25GbE + 16x100GbE\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e25GbE access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003e96x10GbE + 8x100GbE\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e10GbE access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"571\" data-mce-fragment=\"1\"\u003eInterface Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eQSFP+\/QSFP28 ports\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e32 QSFP+ or QSFP28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eSFP+\/SFP28\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e128 x 10GbE SFP+ through QSFP+ to SFP+ breakout cable\u003cbr data-mce-fragment=\"1\"\u003e128 x 25GbE SFP28 through QSFP28 to SFP28 breakout cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eMaximum 10GbE port density\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eMaximum 25GbE port density\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eMaximum 40GbE port density\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eMaximum 50GbE port density\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eMaximum 100GbE port density\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003eManagement and Precision Time Protocol (PTP) interfaces\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003e1 x RJ-45 1GbE port for PTP Grandmaster\u003cbr data-mce-fragment=\"1\"\u003e2 x SMB connectors (one for pulse per second (PPS) output and one for 10 MHz clock output)\u003cbr data-mce-fragment=\"1\"\u003e2 x SFP and 1 x RJ-45 10\/100\/1000 BASE-T for management (only two ports can be used)\u003cbr data-mce-fragment=\"1\"\u003e1 x RS-232 console port\u003cbr data-mce-fragment=\"1\"\u003e1 x USB 2.0 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRack Installation Kit\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003eVersatile four-post mounting options for 19-in server rack or datacom rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eCooling\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003eBack-to-front cooling\u003cbr data-mce-fragment=\"1\"\u003eRedundant (N+1) hot-pluggable fan modules with variable speed to minimize power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"200\" data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd width=\"371\" data-mce-fragment=\"1\"\u003eRedundant (1+1) hot-pluggable 850 W AC\/DC power supplies\u003cbr data-mce-fragment=\"1\"\u003e110-240 V single-phase AC power\u003cbr data-mce-fragment=\"1\"\u003e-36 to -72 V DC power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eMaximum Thermal Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMaximum power draw\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e480 W (AC\/DC), 1638 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTypical power draw\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e380 W (AC\/DC), 1296 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/properties]\n\n\u003cbr\u003e\u003cbr\u003e[specifications]\n\u003ctable width=\"767\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eQFX5200-32C-SAFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eCPU\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eIntel Quad Core Ivy Bridge 1.8 GHz CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMemory\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e16 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eStorage\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e64 GB SSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSystem throughput\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eUp to 6.4 Tbps (bi-directional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eForwarding capacity\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eUp to 2.4 Bpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eTotal packet buffer\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMAC addresses per system\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e136,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eVLAN IDs\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e4,096\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eNumber of link aggregation groups (LAGs)\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eNumber of ports per LAG\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e64 (Number of FCoE VLANs\/FC virtual fabrics: 4095)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eFirewall filters\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eIngress: 768 Routed ACL (RACL), VLAN ACL (VACL), and Port ACL (PACL) rules\u003cbr data-mce-fragment=\"1\"\u003eEgress: 1024 RACL, VACL, and PACL rules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv4 unicast routes\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e128,000 prefixes; 104,000 host routes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv4 multicast routes\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e52,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv6 multicast routes\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e28,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIPv6 unicast routes\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e98,000 prefixes; 52,000 host routes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eAddress Resolution Protocol (ARP) entries\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e32,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eGeneric routing encapsulation (GRE) tunnels\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMPLS labels\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e16,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMPLS IPv4 L3 VPNs (Premium Services License)\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e2048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eJumbo frame\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e9,216 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSpanning Tree Protocol (STP)\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eMultiple Spanning Tree Protocol (MSTP) instances: 64\u003cbr data-mce-fragment=\"1\"\u003eVLAN Spanning Tree Protocol (VSTP) instances: 253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eTraffic mirroring\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eMirroring destination ports per switch: 4\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of mirroring sessions: 4\u003cbr data-mce-fragment=\"1\"\u003eMirroring destination VLANs per switch: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"767\" data-mce-fragment=\"1\"\u003eSoftware Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLayer 2 Features\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eSTP—IEEE 802.1D (802.1D-2004)\u003cbr data-mce-fragment=\"1\"\u003eRapid Spanning Tree Protocol (RSTP) (IEEE 802.1w); MSTP (IEEE 802.1s)\u003cbr data-mce-fragment=\"1\"\u003eBridge protocol data unit (BPDU) protect\u003cbr data-mce-fragment=\"1\"\u003eLoop protect\u003cbr data-mce-fragment=\"1\"\u003eRoot protect\u003cbr data-mce-fragment=\"1\"\u003eRSTP and VSTP running concurrently\u003cbr data-mce-fragment=\"1\"\u003eVLAN—IEEE 802.1Q VLAN trunking\u003cbr data-mce-fragment=\"1\"\u003eRouted VLAN Interface (RVI)\u003cbr data-mce-fragment=\"1\"\u003ePort-based VLAN\u003cbr data-mce-fragment=\"1\"\u003eMAC address filtering\u003cbr data-mce-fragment=\"1\"\u003eQinQ\u003cbr data-mce-fragment=\"1\"\u003eVLAN translation\u003cbr data-mce-fragment=\"1\"\u003eStatic MAC address assignment for interface\u003cbr data-mce-fragment=\"1\"\u003ePer VLAN MAC learning (limit)\u003cbr data-mce-fragment=\"1\"\u003eMAC learning disable\u003cbr data-mce-fragment=\"1\"\u003eLink Aggregation and Link Aggregation Control Protocol (LACP) (IEEE 802.3ad)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1AB Link Layer Discovery Protocol (LLDP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLayer 3 Features (IPv4)\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eStatic routing\u003cbr data-mce-fragment=\"1\"\u003eRIP v1\/v2\u003cbr data-mce-fragment=\"1\"\u003eOSPF v1\/v2\u003cbr data-mce-fragment=\"1\"\u003eOSPF v3\u003cbr data-mce-fragment=\"1\"\u003eFilter-based forwarding\u003cbr data-mce-fragment=\"1\"\u003eVirtual Router Redundancy Protocol (VRRP)\u003cbr data-mce-fragment=\"1\"\u003eIPv6\u003cbr data-mce-fragment=\"1\"\u003eVirtual routers\u003cbr data-mce-fragment=\"1\"\u003eUnicast RPF (uRPF)\u003cbr data-mce-fragment=\"1\"\u003eLoop-free alternate (LFA)\u003cbr data-mce-fragment=\"1\"\u003eBGP (Advanced Services or Premium Services license)\u003cbr data-mce-fragment=\"1\"\u003eIS-IS (Advanced Services or Premium Services license)\u003cbr data-mce-fragment=\"1\"\u003eDynamic Host Configuration Protocol (DHCP) v4\/v6 relay\u003cbr data-mce-fragment=\"1\"\u003eVR-aware DHCP\u003cbr data-mce-fragment=\"1\"\u003eIPv4\/IPv6 over GRE tunnels (interface-based with decap\/encap and firewall-based with decap only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eFibre Channel over Ethernet (FCoE)\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eFCoE transit switch (FIP snooping ACL installation)\u003cbr data-mce-fragment=\"1\"\u003eFCoE session path learning\u003cbr data-mce-fragment=\"1\"\u003eFCoE session health monitoring\u003cbr data-mce-fragment=\"1\"\u003eGraceful restart for FIP snooping\u003cbr data-mce-fragment=\"1\"\u003eFC-BB-6 VN2VN snooping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMulticast Features\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eInternet Group Management Protocol (IGMP) v1\/v2\u003cbr data-mce-fragment=\"1\"\u003eMulticast Listener Discovery (MLD) v1\/v2\u003cbr data-mce-fragment=\"1\"\u003eIGMP proxy, querier\u003cbr data-mce-fragment=\"1\"\u003eIGMP snooping\u003cbr data-mce-fragment=\"1\"\u003eMLD snooping\u003cbr data-mce-fragment=\"1\"\u003eProtocol Independent Multicast PIM-SM, PIM-SSM, PIM-DM, PIM-Bidir*\u003cbr data-mce-fragment=\"1\"\u003eMulticast Source Discovery Protocol (MSDP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eMultichassis link aggregation (MC-LAG)\u003cbr data-mce-fragment=\"1\"\u003eRedundant trunk group (RTG)*\u003cbr data-mce-fragment=\"1\"\u003eLAG load-sharing algorithm—bridged or routed (unicast or multicast) traffic:\u003cbr data-mce-fragment=\"1\"\u003eIP: Session Initiation Protocol (SIP), Dynamic Internet Protocol (DIP), TCP\/UDP source port, TCP\/UDP destination port\u003cbr data-mce-fragment=\"1\"\u003eL2 and non-IP: MAC SA, MAC DA, Ethertype, VLAN ID, source port\u003cbr data-mce-fragment=\"1\"\u003eFCoE packet: Source ID (SID), destination ID (DID), originator exchange ID (OXID), source port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eL2 and L3 QoS: Classification, rewrite, queuing\u003cbr data-mce-fragment=\"1\"\u003eRate limiting:\u003cbr data-mce-fragment=\"1\"\u003eIngress policing: 1-rate 2-color, 2-rate 3-color\u003cbr data-mce-fragment=\"1\"\u003eEgress policing: Policer, policer markdown action\u003cbr data-mce-fragment=\"1\"\u003eEgress shaping: Per queue\u003cbr data-mce-fragment=\"1\"\u003e10 hardware queues per port (8 unicast and 2 multicast)\u003cbr data-mce-fragment=\"1\"\u003eStrict priority queuing (LLQ), shaped-deficit weighted round-robin (SDWRR), weighted random early detection (WRED)\u003cbr data-mce-fragment=\"1\"\u003e802.1p remarking\u003cbr data-mce-fragment=\"1\"\u003eLayer 2 classification criteria: Interface, MAC address, Ethertype, 802.1p, VLAN\u003cbr data-mce-fragment=\"1\"\u003eCongestion avoidance capabilities: WRED\u003cbr data-mce-fragment=\"1\"\u003eTrust IEEE 802.1p (ingress)\u003cbr data-mce-fragment=\"1\"\u003eRemarking of bridged packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSecurity and Filters\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eSecure interface login and password\u003cbr data-mce-fragment=\"1\"\u003eRADIUS\u003cbr data-mce-fragment=\"1\"\u003eTACACS+\u003cbr data-mce-fragment=\"1\"\u003eIngress and egress filters: Allow and deny, port filters, VLAN filters, and routed filters, including management port filters\u003cbr data-mce-fragment=\"1\"\u003eFilter actions: Logging, system logging, reject, mirror to an interface, counters, assign forwarding class, permit, drop, police, mark\u003cbr data-mce-fragment=\"1\"\u003eSSH v1, v2\u003cbr data-mce-fragment=\"1\"\u003eStatic ARP support\u003cbr data-mce-fragment=\"1\"\u003eStorm control, port error disable, and autorecovery\u003cbr data-mce-fragment=\"1\"\u003eControl plane denial-of-service (DoS) protection\u003cbr data-mce-fragment=\"1\"\u003eDHCP snooping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eData Center Bridging (DCB)\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003ePriority-based flow control (PFC)—IEEE 802.1Qbb\u003cbr data-mce-fragment=\"1\"\u003eData Center Bridging Exchange Protocol (DCBX), DCBx FCoE, and iSCSI type, length, and value (TLVs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eHigh Availability\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eSub-second Bidirectional Forwarding Detection (BFD)\u003cbr data-mce-fragment=\"1\"\u003eUplink failure detection (UFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eMPLS\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eStatic label-switched paths (LSPs)\u003cbr data-mce-fragment=\"1\"\u003eRSVP-based signaling of LSPs\u003cbr data-mce-fragment=\"1\"\u003eLDP-based signaling of LSPs\u003cbr data-mce-fragment=\"1\"\u003eLDP tunneling (LDP over RSVP)\u003cbr data-mce-fragment=\"1\"\u003eMPLS class of service (CoS)\u003cbr data-mce-fragment=\"1\"\u003eMPLS access control list (ACL)\/policers\u003cbr data-mce-fragment=\"1\"\u003eMPLS LSR support\u003cbr data-mce-fragment=\"1\"\u003eIPv4 L3 VPN (RFC 2547, 4364)\u003cbr data-mce-fragment=\"1\"\u003eMPLS fast reroute (FRR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eVisibility and Analytics\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eSwitched Port Analyzer (SPAN)\u003cbr data-mce-fragment=\"1\"\u003eRemote SPAN (RSPAN)\u003cbr data-mce-fragment=\"1\"\u003eEncapsulated Remote SPAN (ERSPAN)\u003cbr data-mce-fragment=\"1\"\u003esFlow v5\u003cbr data-mce-fragment=\"1\"\u003eJunos Telemetry Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eServer Virtualization Management and SDN-Related Protocols\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eIEEE 802.1Qbg (VEPA hairpin forwarding)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eDevice Management and Operations\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eRole-based CLI management and access\u003cbr data-mce-fragment=\"1\"\u003eCLI via console, telnet, or SSH\u003cbr data-mce-fragment=\"1\"\u003eExtended ping and traceroute\u003cbr data-mce-fragment=\"1\"\u003eJunos OS configuration rescue and rollback\u003cbr data-mce-fragment=\"1\"\u003eImage rollback\u003cbr data-mce-fragment=\"1\"\u003eSNMP v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003eJunos XML management protocol\u003cbr data-mce-fragment=\"1\"\u003eHigh-frequency statistics collection\u003cbr data-mce-fragment=\"1\"\u003eBeacon LED for port and system\u003cbr data-mce-fragment=\"1\"\u003eAutomation and orchestration\u003cbr data-mce-fragment=\"1\"\u003eZero Touch Provisioning (ZTP)\u003cbr data-mce-fragment=\"1\"\u003eOpenStack Neutron Plug-in\u003cbr data-mce-fragment=\"1\"\u003ePuppet\u003cbr data-mce-fragment=\"1\"\u003eChef\u003cbr data-mce-fragment=\"1\"\u003ePython\u003cbr data-mce-fragment=\"1\"\u003eJunos OS event, commit, and OP scripts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to 10,000 ft (3048 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e5% to 90% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity non-operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0% to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSeismic\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDesigned to meet GR-63, Zone 4 earthquake requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eIEEE Standards\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eIEEE 802.1D\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1w\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1Q\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1p\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1ad\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3ad\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1AB\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3x\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1Qbb\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1Qaz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eT11 Standards\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eINCITS T11 FC-BB-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSupported RFCs\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eRFC 768 UDP\u003cbr data-mce-fragment=\"1\"\u003eRFC 783 Trivial File Transfer Protocol (TFTP)\u003cbr data-mce-fragment=\"1\"\u003eRFC 791 IP\u003cbr data-mce-fragment=\"1\"\u003eRFC 792 ICMP\u003cbr data-mce-fragment=\"1\"\u003eRFC 793 TCP\u003cbr data-mce-fragment=\"1\"\u003eRFC 826 ARP\u003cbr data-mce-fragment=\"1\"\u003eRFC 854 Telnet client and server\u003cbr data-mce-fragment=\"1\"\u003eRFC 894 IP over Ethernet\u003cbr data-mce-fragment=\"1\"\u003eRFC 903 RARP\u003cbr data-mce-fragment=\"1\"\u003eRFC 906 TFTP Bootstrap\u003cbr data-mce-fragment=\"1\"\u003eRFC 951\/1542 BootP\u003cbr data-mce-fragment=\"1\"\u003eRFC 1058 Routing Information Protocol\u003cbr data-mce-fragment=\"1\"\u003eRFC 1112 IGMP v1\u003cbr data-mce-fragment=\"1\"\u003eRFC 1122 Host requirements\u003cbr data-mce-fragment=\"1\"\u003eRFC 1142 OSI IS-IS Intra-domain Routing Protocol\u003cbr data-mce-fragment=\"1\"\u003eRFC 1256 IPv4 ICMP Router Discovery (IRDP)\u003cbr data-mce-fragment=\"1\"\u003eRFC 1492 TACACS+\u003cbr data-mce-fragment=\"1\"\u003eRFC 1519 Classless Interdomain Routing (CIDR)\u003cbr data-mce-fragment=\"1\"\u003eRFC 1587 OSPF NSSA Option\u003cbr data-mce-fragment=\"1\"\u003eRFC 1591 Domain Name System (DNS)\u003cbr data-mce-fragment=\"1\"\u003eRFC 1745 BGP4\/IDRP for IP—OSPF Interaction\u003cbr data-mce-fragment=\"1\"\u003eRFC 1772 Application of the Border Gateway Protocol in the Internet\u003cbr data-mce-fragment=\"1\"\u003eRFC 1812 Requirements for IP Version 4 routers\u003cbr data-mce-fragment=\"1\"\u003eRFC 1997 BGP Communities Attribute\u003cbr data-mce-fragment=\"1\"\u003eRFC 2030 SNTP\u003cbr data-mce-fragment=\"1\"\u003eRFC 2068 HTTP server\u003cbr data-mce-fragment=\"1\"\u003eRFC 2131 BOOTP\/DHCP relay agent\u003cbr data-mce-fragment=\"1\"\u003eRFC 2138 RADIUS Authentication\u003cbr data-mce-fragment=\"1\"\u003eRFC 2139 RADIUS Accounting\u003cbr data-mce-fragment=\"1\"\u003eRFC 2154 OSPF with Digital Signatures (MD5)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2236 IGMP v2\u003cbr data-mce-fragment=\"1\"\u003eRFC 2267 Network ingress filtering\u003cbr data-mce-fragment=\"1\"\u003eRFC 2328 OSPF v2 (edge mode)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2338 VRRP\u003cbr data-mce-fragment=\"1\"\u003eRFC 2362 PIM-SM (edge mode)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2370 OSPF Opaque LSA Option\u003cbr data-mce-fragment=\"1\"\u003eRFC 2385 TCP MD5 Signature Option for BGP\u003cbr data-mce-fragment=\"1\"\u003eRFC 2439 BGP Route Flap Damping\u003cbr data-mce-fragment=\"1\"\u003eRFC 2453 RIP v2\u003cbr data-mce-fragment=\"1\"\u003eRFC 2474 DiffServ field definition (IPv4\/IPv6)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2597 Assured Forwarding PHB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2598 Expedited Forwarding PHB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2697 Single Rate Three Color Marker\u003cbr data-mce-fragment=\"1\"\u003eRFC 2698 Two Rate Three Color Marker\u003cbr data-mce-fragment=\"1\"\u003eRFC 2796 BGP Route Reflection\u003cbr data-mce-fragment=\"1\"\u003eRFC 2918 Route Refresh Capability for BGP-4\u003cbr data-mce-fragment=\"1\"\u003eRFC 3065 Autonomous System Confederations for BGP\u003cbr data-mce-fragment=\"1\"\u003eRFC 3376 IGMP v3 (SSM include mode only)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3392 Capabilities Advertisement with BGP-4\u003cbr data-mce-fragment=\"1\"\u003eRFC 3446 Anycast RP\u003cbr data-mce-fragment=\"1\"\u003eRFC 3569 SSM\u003cbr data-mce-fragment=\"1\"\u003eRFC 3618 MSDP\u003cbr data-mce-fragment=\"1\"\u003eRFC 3623 Graceful OSPF Restart\u003cbr data-mce-fragment=\"1\"\u003eRFC 4271 BGP-4\u003cbr data-mce-fragment=\"1\"\u003eRFC 4360 BGP Extended Communities Attribute\u003cbr data-mce-fragment=\"1\"\u003eRFC 4456 BGP Route Reflection\u003cbr data-mce-fragment=\"1\"\u003eRFC 4486 BGP Cease Notification Subcodes\u003cbr data-mce-fragment=\"1\"\u003eRFC 4724 Graceful Restart Mechanism for BGP\u003cbr data-mce-fragment=\"1\"\u003eRFC 4812 OSPF Restart Signaling\u003cbr data-mce-fragment=\"1\"\u003eRFC 4893 BGP Support for Four-octet AS Number Space\u003cbr data-mce-fragment=\"1\"\u003eRFC 5176 Dynamic Authorization Extensions to RADIUS\u003cbr data-mce-fragment=\"1\"\u003eRFC 5396 Textual Representation of AS Numbers\u003cbr data-mce-fragment=\"1\"\u003eRFC 5668 4-Octet AS Specific BGP Extended Community\u003cbr data-mce-fragment=\"1\"\u003eRFC 5880 Bidirectional Forwarding Detection (BFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSupported MIBs\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eRFC 1155 SMI\u003cbr data-mce-fragment=\"1\"\u003eRFC 1157 SNMPv1\u003cbr data-mce-fragment=\"1\"\u003eRFC 1212, RFC 1213, RFC 1215 MIB-II, Ethernet-Like MIB and TRAPs\u003cbr data-mce-fragment=\"1\"\u003eRFC 1850 OSPFv2 MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 1901 Introduction to Community-based SNMPv2\u003cbr data-mce-fragment=\"1\"\u003eRFC 2011 SNMPv2 for Internet Protocol using SMIv2\u003cbr data-mce-fragment=\"1\"\u003eRFC 2012 SNMPv2 for TCP using SMIv2\u003cbr data-mce-fragment=\"1\"\u003eRFC 2013 SNMPv2 for UDP using SMIv2\u003cbr data-mce-fragment=\"1\"\u003eRFC 2233 Interfaces Group MIB using SMIv2\u003cbr data-mce-fragment=\"1\"\u003eRFC 2287 System Application Packages MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2570 Introduction to SNMPv3\u003cbr data-mce-fragment=\"1\"\u003eRFC 2571 SNMP Framework Architecture (read-only access)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2572 SNMP Message Processing and Dispatching (read-only access)\u003cbr data-mce-fragment=\"1\"\u003eRFC 2576 Coexistence of SNMP v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003eRFC 2578 SNMP SMI MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2579 SNMP Textual Conventions for SMIv2\u003cbr data-mce-fragment=\"1\"\u003eRFC 2580 Conformance Statements for SMIv2\u003cbr data-mce-fragment=\"1\"\u003eRFC 2665 Ethernet-like interface MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2787 VRRP MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2790 Host Resources MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2819 RMON MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2863 Interface Group MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 2932 IPv4 Multicast MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 3410 SNMP Framework Introduction and Applicability\u003cbr data-mce-fragment=\"1\"\u003eRFC 3411 SNMP Framework Architecture\u003cbr data-mce-fragment=\"1\"\u003eRFC 3412 SNMP Message Processing and Dispatching\u003cbr data-mce-fragment=\"1\"\u003eRFC 3413 SNMP Applications (all MIBs except Proxy MIB)\u003cbr data-mce-fragment=\"1\"\u003eRFC 3414 USM for SNMP\u003cbr data-mce-fragment=\"1\"\u003eRFC 3415 VACM for SNMP\u003cbr data-mce-fragment=\"1\"\u003eRFC 3416 SNMP Protocol Operations v2\u003cbr data-mce-fragment=\"1\"\u003eRFC 3417 Transport Mappings for SNMP\u003cbr data-mce-fragment=\"1\"\u003eRFC 3418 SNMP MIB\u003cbr data-mce-fragment=\"1\"\u003eRFC 3584 Coexistence of SNMP v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003eRFC 3826 AES Cipher Algorithm in SNMP USM\u003cbr data-mce-fragment=\"1\"\u003eRFC 4188 Managed Objects for Bridges\u003cbr data-mce-fragment=\"1\"\u003eRFC 4318 Managed Objects for Bridges with RSTP\u003cbr data-mce-fragment=\"1\"\u003eRFC 4363 Q-Bridge VLAN MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eSafety\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003eCAN\/CSA-C22.2 No. 60950-1 Information Technology Equipment—Safety\u003cbr data-mce-fragment=\"1\"\u003eUL 60950-1 Information Technology Equipment—Safety\u003cbr data-mce-fragment=\"1\"\u003eEN 60950-1 Information Technology Equipment—Safety\u003cbr data-mce-fragment=\"1\"\u003eIEC 60950-1 Information Technology Equipment—Safety (all country deviations)\u003cbr data-mce-fragment=\"1\"\u003eEN 60825-1 Safety of Laser Products—Part 1: Equipment Classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"384\" data-mce-fragment=\"1\"\u003eEMC\u003c\/td\u003e\n\u003ctd width=\"383\" data-mce-fragment=\"1\"\u003e47 CFR Part 15 (FCC), Class A\u003cbr data-mce-fragment=\"1\"\u003eICES-003 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55022\/EN 55032, Class A\u003cbr data-mce-fragment=\"1\"\u003eCISPR 22\/CISPR 32, Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55024\u003cbr data-mce-fragment=\"1\"\u003eCISPR 24\u003cbr data-mce-fragment=\"1\"\u003eEN 300 386\u003cbr data-mce-fragment=\"1\"\u003eVCCI Class A\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS CISPR 32, Class A\u003cbr data-mce-fragment=\"1\"\u003eKN32\/KN35\u003cbr data-mce-fragment=\"1\"\u003eBSMI CNS 13438, Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-3-2\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-3-3\u003cbr data-mce-fragment=\"1\"\u003eETSI\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019: Environmental Conditions \u0026amp; Environmental Tests for Telecommunications Equipment\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-1 (2000)—Storage\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-2 (1999)—Transportation\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-3 (2003)—Stationary Use at Weather-protected Locations\u003cbr data-mce-fragment=\"1\"\u003eETSI EN 300 019-2-4 (2003)—Stationary Use at Non-Weather-protected Locations\u003cbr data-mce-fragment=\"1\"\u003eETS 300753 (1997)—Acoustic noise emitted by telecommunications equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/specifications]\n\n\u003cbr\u003e\u003cbr\u003e[accesories]\n\u003ctable width=\"422\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"422\" data-mce-fragment=\"1\"\u003eAccessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJPSU-850W-AC-AFI\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eJuniper 850 W AC power supply for QFX5100-96S and QFX5200-32C (power supply-side airflow intake)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX5200-32C-FANAFI\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQFX5200-32C fan module, back-to-front airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eEX-4PST-RMK\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eAdjustable 4-post rack-mount kit for EX Series, QFX5100, and QFX5200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eSoftware Licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX5000-35-JBS\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eBase Services license for QFX5200-32C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX5000-35-JAS\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eAdvanced Services license for QFX5200-32C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX5000-35-JPS\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003ePremium Services license for QFX5200-32C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eOptics and Transceivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-10GE-USR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE Ultra Short Reach optics, 850 nm for 10 m on OM1, 20 m on OM2, 100 m on OM3 multimode fiber (for management port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-10GE-SR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-SR 10GbE optics, 850 nm for up to 300 m transmission on MMF (for management port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-10GE-LR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-LR 10GbE optics, 1310 nm for 10 km transmission on SMF (for management port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-1M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE direct attach copper (DAC) twinax cable, 1 m (for QFX5200-48Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-3M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE DAC twinax cable, 3 m (for QFX5200-48Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eQFX-SFP-DAC-5M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP+ 10GbE DAC twinax cable, 5 m (for QFX5200-48Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJNP-SFP-25G-SR\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003e25GBASE-SR SFP28 module for MMF (for QFX5200-48Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJNP-SFP-25G-DAC-1M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP28 25GBASE DAC cable, 1 m (for QFX5200-48Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJNP-SFP-25G-DAC-3M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP28 25GBASE DAC cable, 3 m (for QFX5200-48Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJNP-SFP-25G-DAC-5M\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eSFP28 25GBASE DAC cable, 5 m (for QFX5200-48Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJNP-QSFP-40GE-IR4\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQSFP+ 40GBASE-IR4 optics, 1310 nm for up to 2 km transmission on SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"150\" data-mce-fragment=\"1\"\u003eJNP-QSFP-40G-LR4\u003c\/td\u003e\n\u003ctd width=\"272\" data-mce-fragment=\"1\"\u003eQSFP+ 40GBASE-LR4 optics, 1310 nm for up to 10 km transmission on SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n[\/accesories]\n\n\u003ch2\u003eJuniper QFX5200-32C-SAFI Switch\u003c\/h2\u003e\n\u003cp\u003eJuniper QFX5200-32C-SAFI is a 1U QFX5200 Series fixed-configuration Ethernet switch with SONiC, 32 x QSFP+\/QSFP28 ports, redundant fans, dual AC power supplies, and back-to-front airflow for data center deployments.\u003c\/p\u003e\n\u003cp\u003eThis model supports flexible spine\/leaf and breakout configurations, delivering up to 6.4 Tbps system throughput and up to 2.4 Bpps forwarding capacity in a compact 1U form factor.\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48958310514944,"sku":"QFX5200-32C-SAFI-NEW","price":36775.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/QFX5200-32C_06c595c7-6394-49a9-820f-fc1df7a84d1c.jpg?v=1783446222","url":"https:\/\/alotechparts.com\/products\/juniper-qfx5200-32c-safi-switch","provider":"Alo Tech Solutions","version":"1.0","type":"link"}