{"product_id":"jcpu2-640-notifier-central-processing-unit-for-nfs2-640-fire-alarm-system-120v-ac-5060hz","title":"JCPU2-640 | Notifier Central Processing Unit for NFS2-640 Fire Alarm System, 120V AC, 50\/60Hz","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier JCPU2-640 is a central processing unit (CPU) designed for use with the NFS2-640 intelligent fire alarm control panel. Operating on 120 VAC power at 50\/60 Hz, it provides control, monitoring, and communication functions for both stand-alone and networked fire alarm systems requiring a main display interface.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eNotifier (by Honeywell)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eJCPU2-640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eCentral Processing Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eNFS2-640 Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003e120 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eOccupies three chassis positions in the main layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eDisplay Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eSupports JNCA-2 Primary Display (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003e640-character backlit LCD when paired with display unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eOne built-in Signaling Line Circuit (expandable to two)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eOperation Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eStand-alone or networked (with network control options)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eProcessor Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eManages detection, control, and event logging for fire systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eNetworking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eSupports Notifier fire system network configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003ePrimary control and monitoring module for NFS2-640 systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003eFactory-mounted on chassis; includes installation and programming manuals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6973%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.988%;\"\u003e8.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eJCPU2-640\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe JCPU2-640 is the primary control and processing component for the Notifier NFS2-640 intelligent fire alarm system. It integrates central logic processing, system communication, and loop control within a single chassis-mounted assembly. The unit includes one factory-installed Signaling Line Circuit (SLC) that can be expanded to two, supporting large-scale detection and monitoring networks. It manages system events, alarm processing, and supervision, ensuring fast and reliable fire detection performance. When used with the JNCA-2 display module, it provides a 640-character backlit interface for real-time system information. Designed for both standalone and networked configurations, the JCPU2-640 offers high performance and flexibility for advanced fire protection installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated CPU Assembly: Combines processing, loop control, and power supply in a single, factory-mounted chassis module.\u003c\/li\u003e\n\u003cli\u003eFlexible System Configuration: Supports both stand-alone and networked operation for scalable fire alarm installations.\u003c\/li\u003e\n\u003cli\u003eExpandable SLC Capability: Comes with one Signaling Line Circuit, expandable to two for extended device capacity.\u003c\/li\u003e\n\u003cli\u003eDisplay Compatibility: Interfaces with the JNCA-2 optional primary display providing a 640-character backlit LCD readout.\u003c\/li\u003e\n\u003cli\u003eReliable Power Architecture: Operates on 120 VAC input, with an integral power supply for consistent performance.\u003c\/li\u003e\n\u003cli\u003eCompact Mounting Design: Occupies three chassis positions in the first layer, optimizing panel space utilization.\u003c\/li\u003e\n\u003cli\u003eAdvanced System Control: Executes alarm logic, monitoring, and event management functions for full fire system supervision.\u003c\/li\u003e\n\u003cli\u003eNotifier Network Support: Integrates seamlessly into networked NFS2-640 systems, enabling multi-panel coordination and data sharing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe JCPU2-640 delivers the reliability and precision required for centralized control and monitoring in Notifier’s NFS2-640 intelligent fire detection systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105154441472,"sku":"JCPU2-640","price":8665.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/75f2add81d304e0d9b8b3ca0f5afe430.jpg?v=1785541459","url":"https:\/\/alotechparts.com\/products\/jcpu2-640-notifier-central-processing-unit-for-nfs2-640-fire-alarm-system-120v-ac-5060hz","provider":"Alo Tech Solutions","version":"1.0","type":"link"}