{"product_id":"ili95-mb-e3-gamewell-fci-intelligent-loop-interface-main-board-for-e3-series-systems","title":"ILI95-MB-E3 | Gamewell-FCI Intelligent Loop Interface Main Board for E3 Series Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Gamewell-FCI ILI95-MB-E3 Intelligent Loop Interface Main Board is a key control module designed for E3 Series® fire alarm and mass notification systems. It serves as the main circuit interface, providing two signaling line circuits, notification appliance circuits, relay functions, and auxiliary power output for system integration. The ILI95-MB-E3 ensures fast communication, efficient system control, and reliable performance in complex building safety environments.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGamewell-FCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm \u0026amp; Life Safety Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eILI95-MB-E3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntelligent Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApollo SLC protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Line Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo Class A or B (Style 4, 6, or 7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e126 addressable devices per SLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotification Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo NACs, Class A or B, 2.0 A each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS-485 Connectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports 16 ASM-16\/ANU-48 and 6 LCD-E3 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e625K baud ARCNET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvent History Log\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4100 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm, trouble, and supervisory Form “C” contacts (2A @ 30 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 864 9th Edition, UL 2572\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Expansion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANX board (up to 122 nodes), RPT-E3 repeater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary power and local energy city box output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork-ready main board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.00 × 6.00 × 10.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eILI95-MB-E3\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe ILI95-MB-E3 is an advanced main interface board engineered for use with Gamewell-FCI E3 Series® Expandable Emergency Evacuation and Combined Fire and Mass Notification Systems. It operates using Apollo protocol SLC devices and features a powerful 32-bit RISC processor for rapid data processing and precise control. The module supports up to 126 addressable devices per loop, offering scalability through RS-485 connectivity for additional modules and annunciators. With integral network capability at 625K baud, UL 864 and UL 2572 compliance, and optional fiber-optic communication via the RPT-E3 repeater, this module delivers reliable performance in mission-critical fire and evacuation systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual Signaling Line Circuits: Supports two SLCs with up to 126 Apollo addressable devices per loop.\u003c\/li\u003e\n\u003cli\u003eHigh-Speed Network Communication: Operates on a 625K baud ARCNET network for rapid data transmission.\u003c\/li\u003e\n\u003cli\u003eIntegrated Notification Circuits: Provides two Class A or B notification appliance circuits rated at 2.0 amps each.\u003c\/li\u003e\n\u003cli\u003eFlexible Connectivity: RS-485 interface supports up to 16 ASM-16 or ANU-48 LED driver modules and 6 LCD-E3 annunciators.\u003c\/li\u003e\n\u003cli\u003eAdvanced Processing: Equipped with a 32-bit RISC processor for enhanced response time and reliability.\u003c\/li\u003e\n\u003cli\u003eEvent Logging: Stores up to 4100 system events for diagnostics and maintenance tracking.\u003c\/li\u003e\n\u003cli\u003eUL Listed for Safety: Complies with UL 864 (9th Edition) and UL 2572 for mass notification systems.\u003c\/li\u003e\n\u003cli\u003eOptional Fiber-Optic Expansion: Compatible with RPT-E3 for signal boosting, transient protection, and extended communication distance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ILI95-MB-E3 delivers the reliability and precision required for intelligent fire detection and emergency communication control.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":49105141596416,"sku":"ILI95-MB-E3","price":1321.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ILI95-MB-E3.jpg?v=1785541163","url":"https:\/\/alotechparts.com\/products\/ili95-mb-e3-gamewell-fci-intelligent-loop-interface-main-board-for-e3-series-systems","provider":"Alo Tech Solutions","version":"1.0","type":"link"}