{"product_id":"hwf2v-com-honeywell-lteip-digital-cellular-fire-alarm-communicator","title":"HWF2V-COM | Honeywell LTE\/IP Digital Cellular Fire Alarm Communicator","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"104\" data-end=\"512\"\u003eThe Honeywell HWF2V-COM is a digital cellular and IP fire alarm communicator that transmits alarm signals from a Fire Alarm Control Panel (FACP) over Verizon’s LTE network or Ethernet\/IP connection. Designed for reliability and redundancy, it supports LTE-only, IP-only, or hybrid configurations, ensuring continuous monitoring and secure signal transmission using AES 256-bit encryption.\u003c\/p\u003e\n\u003ch3 data-start=\"502\" data-end=\"534\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 646.8px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eFire Alarm Communication Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eHWF2V-COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eFire Alarm Communicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eHWF2-COM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eLTE (Verizon) and Ethernet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 39.2px;\"\u003e\u003cstrong\u003eCommunication Paths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 39.2px;\"\u003eLTE Cellular, IP, or IP Primary with LTE Backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 39.2px;\"\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 39.2px;\"\u003eLTE, HSPA+ (4G), HSPA (3G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 39.2px;\"\u003e\u003cstrong\u003eSupervision Intervals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 39.2px;\"\u003eSelectable: 5 min, 60 min, 6 hr, 24 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 39.2px;\"\u003e\u003cstrong\u003eEncryption Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 39.2px;\"\u003eAES 256-Bit (Advanced Encryption Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 39.2px;\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 39.2px;\"\u003eFire Alarm Control Panels with DACT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 39.2px;\"\u003e\u003cstrong\u003eConnection Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 39.2px;\"\u003eConnects to Primary and Secondary DACT Telephone Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003e10\/100 Base Ethernet (LAN or WAN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eIP Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eDHCP, Static (Public or Private)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eBuilt-In with Charging Circuit for Battery Backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Supervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003ePrimary Power and Battery Supervision Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eDiagnostic Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eLED Indicators for Signal Strength and Status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 39.2px;\"\u003e\u003cstrong\u003eQuality of Service (QOS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 39.2px;\"\u003eReports Signal Strength, Message Path, and Delivery Confirmation via AlarmNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eProgramming Tool\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eCompatible with 7720P Handheld Programmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eWall-Mount Communication Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eSteel Communication Box with Lockable Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 39.2px;\"\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 39.2px;\"\u003e14.875 in × 12.75 in × 3.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003e5.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.3619%; height: 19.6px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5049%; height: 19.6px;\"\u003eUL Listed for Fire Alarm Use, FCC Certified, NFPA 72 Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eHWF2V-COM\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe HWF2V-COM is part of Honeywell’s HWF2-COM Series of digital fire alarm communicators, built for secure, dual-path signal transmission between fire alarm systems and monitoring centers. It supports three selectable communication options—cellular LTE, Ethernet\/IP, or a combination of both for backup redundancy—ensuring uninterrupted connectivity. The communicator easily connects to any FACP equipped with a DACT (Digital Alarm Communicator Transmitter) via the standard telephone ports, requiring no panel reconfiguration. Its integrated power supply includes battery charging and supervision, allowing continuous operation during AC power loss. Daily automated testing of both IP and LTE connections ensures system readiness, while diagnostic LEDs and QOS reporting provide real-time signal and network status updates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual-Path Communication: Supports LTE and Ethernet\/IP transmission, configurable for LTE-only, IP-only, or IP Primary with LTE Backup modes.\u003c\/li\u003e\n\u003cli\u003eSecure Data Encryption: Utilizes AES 256-bit encryption to ensure data integrity and prevent unauthorized signal interception.\u003c\/li\u003e\n\u003cli\u003eSeamless FACP Integration: Connects directly to the fire panel’s primary and secondary phone ports without modifying existing configurations.\u003c\/li\u003e\n\u003cli\u003eFlexible Network Options: Works with Verizon LTE, HSPA+\/3G, and 10\/100 Base Ethernet connections for broad compatibility.\u003c\/li\u003e\n\u003cli\u003eSelectable Supervision Intervals: Allows flexible monitoring frequency—5 minutes, 1 hour, 6 hours, or 24 hours—based on site requirements.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Power System: Includes an onboard power supply with charging circuit and battery supervision for uninterrupted operation.\u003c\/li\u003e\n\u003cli\u003eComprehensive Diagnostics: Diagnostic LEDs and AlarmNet QOS reporting provide real-time information on connection strength, message routing, and status.\u003c\/li\u003e\n\u003cli\u003eQuick Configuration: Compatible with Honeywell’s 7720P handheld programmer for fast setup and commissioning.\u003c\/li\u003e\n\u003cli\u003eRobust Construction: Housed in a durable steel enclosure designed for easy installation and long service life in commercial environments.\u003c\/li\u003e\n\u003cli\u003eRegulatory Compliance: Meets UL, FCC, and NFPA 72 standards for fire alarm signaling and monitoring applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HWF2V-COM delivers the reliability and precision required for modern fire alarm communication, ensuring secure, redundant, and compliant alarm transmission across LTE and IP networks.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105127997696,"sku":"HWF2V-COM","price":576.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/HWF2V-COM-c1-6.jpg?v=1785540898","url":"https:\/\/alotechparts.com\/products\/hwf2v-com-honeywell-lteip-digital-cellular-fire-alarm-communicator","provider":"Alo Tech Solutions","version":"1.0","type":"link"}