{"product_id":"hpf602ulada-honeywell-60-a-fire-alarm-notification-power-supply-24vdc-ul-listed","title":"HPF602ULADA | Honeywell 6.0 A Fire Alarm Notification Power Supply, 24VDC, UL Listed","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Honeywell HPF602ULADA Fire Alarm Power Supply is a 6.0 A notification power expander designed to extend and support fire alarm and security systems with reliable, regulated power. It features a built-in AC power connection, battery charging circuit, and backup battery space, making it an ideal choice for powering notification appliances required under ADA compliance.\u003c\/p\u003e\n\u003cp\u003eWith advanced switch-mode design, ANSI cadence pattern output, and built-in synchronization for System Sensor, Gentex, Wheelock, and Faraday appliances, the HPF602ULADA offers superior value and performance. Its lightweight design simplifies installation while providing full supervision and dependable operation in critical applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100.083%; height: 548.626px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003eHoneywell Power Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003eFire Alarm Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003eHPF602ULADA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003e783196011387\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eAlso Known As\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003e0H-F602ULADA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003e120 VAC at 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003e24 VDC @ 6.0 A (total across all outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Per Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003e3.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 39.1875px;\"\u003e\u003cstrong\u003eOutput Configurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 39.1875px;\"\u003e2 Class A, 4 Class B, or 1 Class A + 2 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eAuxiliary Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003e4 continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003e2 (configurable as 2 Class A or 2 Class B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 39.1875px;\"\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 39.1875px;\"\u003e9–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003eSupports up to 33 AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 39.1875px;\"\u003e\u003cstrong\u003eCurrent Draw (Battery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 39.1875px;\"\u003e75 mA standby, 175 mA alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 39.1875px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 39.1875px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003e85% non-condensing max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003e16.0\" H × 12.25\" W × 3.0\" D (40.64 × 30.88 × 7.62 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 39.1875px;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 39.1875px;\"\u003eAC Power (green), Battery Trouble (yellow), Ground Fault (yellow), Output Troubles (yellow)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 39.1875px;\"\u003e\u003cstrong\u003eCompliance Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 39.1875px;\"\u003eUL 864, UL 1481, NFPA 72, CSFM Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 26.4591%; height: 19.5938px;\"\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.4054%; height: 19.5938px;\"\u003eUL Listed (File S6677), CSFM: 7300-1637\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About HPF602ULADA\u003c\/h4\u003e\n\u003cp\u003eThe Honeywell HPF602ULADA expands fire alarm system capacity by delivering up to 6.0 A of filtered 24 VDC power to support horns, strobes, and other notification appliances. It allows connection to Class A or Class B type circuits and ensures instantaneous switchover to standby battery power in the event of AC failure.\u003c\/p\u003e\n\u003cp\u003eBuilt-in diagnostics and LED indicators simplify troubleshooting, while UL 864, UL 1481, NFPA 72, and CSFM compliance ensure reliable and code-approved system performance. Whether powering additional devices, syncing strobes across large systems, or upgrading legacy panels with cadence capability, the HPF602ULADA provides a robust and cost-effective solution.\u003c\/p\u003e\n\u003cp data-start=\"1236\" data-end=\"1255\"\u003e\u003cstrong data-start=\"1236\" data-end=\"1253\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 6.0 A of notification appliance power.\u003c\/li\u003e\n\u003cli\u003e24 VDC filtered output with switch-mode design.\u003c\/li\u003e\n\u003cli\u003eFour power-limited outputs: configurable as 2 Class A, 4 Class B, or 1 Class A + 2 Class B.\u003c\/li\u003e\n\u003cli\u003eAdditional continuous auxiliary output.\u003c\/li\u003e\n\u003cli\u003eBuilt-in synchronization for System Sensor, Gentex, Wheelock, and Faraday appliances.\u003c\/li\u003e\n\u003cli\u003eANSI cadence pattern output for upgrading older panels.\u003c\/li\u003e\n\u003cli\u003eInstant battery switchover during AC failure.\u003c\/li\u003e\n\u003cli\u003eLED indicators for quick diagnosis of power, ground fault, and trouble conditions.\u003c\/li\u003e\n\u003cli\u003eLightweight design reduces installation time and shipping cost.\u003c\/li\u003e\n\u003cli\u003eFully compliant with UL 864, UL 1481, and NFPA 72 fire safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105230692608,"sku":"HPF602ULADA","price":1065.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/hpf602ulada_1.jpg?v=1785543098","url":"https:\/\/alotechparts.com\/products\/hpf602ulada-honeywell-60-a-fire-alarm-notification-power-supply-24vdc-ul-listed","provider":"Alo Tech Solutions","version":"1.0","type":"link"}