{"product_id":"hpf-ps6-honeywell-6-amp-remote-power-supply-and-nac-expander","title":"HPF-PS6 | Honeywell 6-Amp Remote Power Supply and NAC Expander","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Honeywell HPF-PS6 is a 6-amp remote power supply and NAC expander that delivers regulated 24 VDC across up to five configurable outputs. It supports Class A or Class B wiring, UL-listed synchronization, ANSI Temporal 3\/4 coding, and includes an integral battery charger for extended backup capability.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 431.063px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eHPF-PS6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eRemote Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003e6 A total, 3 A maximum per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eUp to 5 independently configurable (NACs or auxiliary power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003e120 VAC ±10 %, 50\/60 Hz, 5.0 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eWiring Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eClass A or Class B (via ZNAC-PS converter card, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eUL-listed sync for System Sensor, Wheelock, Gentex, AMSECO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 39.1875px;\"\u003e\u003cstrong\u003eConfigurable Codes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 39.1875px;\"\u003eANSI Temporal 3 or Temporal 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eTwo isolated inputs (reverse-polarity NAC or dry contact, 9–32 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eDual Form C trouble relays (AC Trouble, General Trouble)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eEnd-of-line 2 kΩ to 27 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eSelectable earth fault detection (enable\/disable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eIntegral charger, supports up to 33 AH external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Housing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eTwo 7 AH or two 18 AH batteries inside cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 39.1875px;\"\u003e\u003cstrong\u003eDiagnostic Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 39.1875px;\"\u003eIndividual NAC power\/trouble LEDs, trouble history mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003eRed steel enclosure with plug-in terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 21.9509%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.1714%; height: 19.5938px;\"\u003e24 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eHPF-PS6\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe HPF-PS6 is a Honeywell PS Series 6-amp remote power supply and NAC expander designed to extend fire alarm system capacity. It provides five configurable 24 VDC outputs that can be wired as Class A or Class B, with up to 3 A per circuit and 6 A total output. The unit supports synchronized operation with System Sensor, Wheelock, Gentex, and AMSECO notification appliances and can apply ANSI Temporal 3 or Temporal 4 coding. Built with DIP-switch configuration, dual Form C trouble relays, and diagnostic LEDs, the HPF-PS6 simplifies setup, reduces commissioning time, and ensures reliable monitoring for commercial fire alarm applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFive Configurable Outputs: Provides up to 5 NAC or auxiliary circuits rated at 3 A each, 6 A combined.\u003c\/li\u003e\n\u003cli\u003eClass A\/B Flexibility: Converts from Class B to Class A wiring with ZNAC-PS card without reducing outputs.\u003c\/li\u003e\n\u003cli\u003eAppliance Synchronization: UL-listed sync with System Sensor, Wheelock, Gentex, and AMSECO devices.\u003c\/li\u003e\n\u003cli\u003eCoding Options: Configurable for ANSI Temporal 3 or Temporal 4 signaling patterns.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Tools: Includes NAC power\/trouble LEDs and trouble history mode for service support.\u003c\/li\u003e\n\u003cli\u003eIntegrated Charging: Built-in battery charger supports charging up to 33 AH for extended operation.\u003c\/li\u003e\n\u003cli\u003eBattery Housing: Accommodates two 7 AH or two 18 AH batteries internally for backup power.\u003c\/li\u003e\n\u003cli\u003eFlexible Control: Accepts two isolated inputs, supporting NAC triggers or dry contact activation.\u003c\/li\u003e\n\u003cli\u003eEnhanced Safety: Dual Form C trouble relays monitor AC power and general system conditions.\u003c\/li\u003e\n\u003cli\u003eSimplified Setup: DIP-switch programming eliminates the need for external software configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HPF-PS6 delivers the reliability and precision required for powering fire alarm notification appliances and system peripherals in commercial and institutional facilities.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105201824000,"sku":"HPF-PS6","price":774.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/fl-ps10_lg_1_1_2.webp?v=1785542448","url":"https:\/\/alotechparts.com\/products\/hpf-ps6-honeywell-6-amp-remote-power-supply-and-nac-expander","provider":"Alo Tech Solutions","version":"1.0","type":"link"}