{"product_id":"honeywell-c7012e1104-self-checking-uv-flame-detector-120-vac-nema-4-for-burner-safety","title":"Honeywell C7012E1104 Self-Checking UV Flame Detector 120 VAC NEMA 4 for Burner Safety","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003eThe Honeywell C7012E1104 is a self-checking UV flame detector designed for use with gas, oil, or coal-fired burners. This detector features solid-state circuitry and operates at 120 VAC to provide reliable flame monitoring in industrial combustion systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 385.204px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 30.8594px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 29.6364%; text-align: left; height: 30.8594px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 70%; height: 30.8594px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.5938px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 29.6364%; text-align: left; height: 21.5938px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 70%; height: 21.5938px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 19.5938px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 19.5938px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003eFlame Safety\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 19.5938px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 19.5938px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eC7012E1104\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.5938px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 20.5938px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 20.5938px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eUV Flame Detectors\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.0625px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 25.0625px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 25.0625px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan\u003eC7012E – UV Purple Peeper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 29.1875px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 29.1875px;\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 29.1875px;\"\u003e120 VAC\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.1875px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 24.1875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eFrequency\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 24.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.1875px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 25.1875px;\"\u003ePower Consumption\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 25.1875px;\"\u003e7.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 19.5938px;\"\u003eMounting Thread\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 19.5938px;\"\u003e3\/4 in. NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 39.1875px;\"\u003eAmbient Temp Range\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 39.1875px;\"\u003e-20°F to +175°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 26.1875px;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 26.1875px;\"\u003eCast aluminum, NEMA 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 19.5938px;\"\u003eElectrical Connection\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 19.5938px;\"\u003e6 NEC Class 1 color-coded lead wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 19.5938px;\"\u003eUsed With\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 19.5938px;\"\u003eR7247C, R7847C Flame Amplifiers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.5938px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 25.5938px;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 25.5938px;\"\u003e5 1\/4\" diameter × 7 7\/32\" length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 29.6364%; text-align: left; height: 19.5938px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 70%; height: 19.5938px;\"\u003e\u003cspan\u003e1.9 kg\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eC7012E1104\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe C7012E1104 is part of Honeywell’s C7012E Series of ultraviolet flame detectors, engineered for applications requiring continuous flame verification and high safety standards. This model features self-checking functionality that works with compatible flame safeguard controls to automatically verify detector health, reducing the need for manual testing. It operates at 120 VAC with a frequency of 50\/60 Hz and consumes just 7.0 watts of power. Housed in a rugged cast aluminum enclosure with a NEMA 4 rating, the detector mounts via a 3\/4-inch NPT threaded connection and is built to withstand harsh environments, with an ambient operating range from -20°F to +175°F. The unit comes equipped with six color-coded NEC Class 1 lead wires for easy electrical connection and integrates with Honeywell flame amplifiers such as the R7247C and R7847C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUV Flame Detection: Detects ultraviolet radiation emitted by combustion flames, ideal for gas, oil, or coal-fired systems.\u003c\/li\u003e\n\u003cli\u003eSelf-Checking Feature: Continuously verifies system integrity, eliminating the need for periodic manual testing.\u003c\/li\u003e\n\u003cli\u003eSolid-State Electronics: Ensures reliable performance and extended product life in demanding environments.\u003c\/li\u003e\n\u003cli\u003eNEMA 4 Cast Housing: Weather-resistant design suitable for indoor and outdoor industrial settings.\u003c\/li\u003e\n\u003cli\u003eSimple Mounting: 3\/4 in. NPT threaded connection for quick installation.\u003c\/li\u003e\n\u003cli\u003eWide Operating Range: Tolerates ambient temperatures from -20°F to +175°F for flexible deployment.\u003c\/li\u003e\n\u003cli\u003eElectrical Compatibility: Works with R7247C and R7847C flame amplifiers, commonly used in Honeywell burner safety systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe C7012E1104 ensures safe and continuous flame detection with built-in diagnostics for high-reliability burner control.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105371005184,"sku":"C7012E1104","price":6319.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/8f99bed8e6364e508576f1d42482d790.jpg?v=1785545733","url":"https:\/\/alotechparts.com\/products\/honeywell-c7012e1104-self-checking-uv-flame-detector-120-vac-nema-4-for-burner-safety","provider":"Alo Tech Solutions","version":"1.0","type":"link"}