{"product_id":"hmx3b800-siemens-800a-3-pole-600v-molded-case-circuit-breaker-65ka-at-480v-vl-series","title":"HMX3B800 | Siemens 800A 3-Pole 600V Molded Case Circuit Breaker, 65kA @ 480V, VL Series","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens HMX3B800 Molded Case Circuit Breaker provides reliable circuit protection for high-capacity electrical distribution systems. This 3-pole, 800-amp breaker operates at 600 volts AC with an interrupting capacity of 65kA at 480V. The HMX3B800 features a bolt-on connection and thermal magnetic trip unit, ensuring dependable overload and short-circuit protection in demanding industrial applications.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHMX3B800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVL Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHMX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMG Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanelboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMexico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eHMX3B800\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe HMX3B800 is part of Siemens’ VL Series, designed to deliver high-performance protection for large-scale electrical systems. It utilizes a bolt-on mounting configuration suitable for panelboard and switchgear installations. With a thermal magnetic trip mechanism, it combines long-time and instantaneous trip functionality to prevent equipment damage from electrical faults. Built for global use and tested to exceed UL endurance standards, the HMX3B800 offers robust performance and compatibility across a range of industrial and commercial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated for 65kA at 480V to handle heavy-duty fault currents.\u003c\/li\u003e\n\u003cli\u003eThermal Magnetic Protection: Combines overload and short-circuit protection in one compact unit.\u003c\/li\u003e\n\u003cli\u003eBolt-On Design: Ensures secure mounting for stable electrical connections.\u003c\/li\u003e\n\u003cli\u003e3-Pole, 800A Configuration: Ideal for high-current, three-phase systems up to 600V.\u003c\/li\u003e\n\u003cli\u003eVL Series Compatibility: Modular design supports system flexibility and accessory integration.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Meets industry safety and reliability standards.\u003c\/li\u003e\n\u003cli\u003eCompact Construction: Saves panel space and simplifies system layout.\u003c\/li\u003e\n\u003cli\u003eGlobal Design: Supports worldwide applications with uniform footprint and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HMX3B800 delivers the reliability and precision required for high-capacity electrical protection in industrial power distribution systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105123246336,"sku":"HMX3B800","price":13075.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-10-21_18.26.28.png?v=1785540764","url":"https:\/\/alotechparts.com\/products\/hmx3b800-siemens-800a-3-pole-600v-molded-case-circuit-breaker-65ka-at-480v-vl-series","provider":"Alo Tech Solutions","version":"1.0","type":"link"}