{"product_id":"hja260702-schneider-electric-square-d-70a-2-pole-600vac-powerpact-h-molded-case-circuit-breaker","title":"HJA260702 | Schneider Electric Square D 70A 2-Pole 600VAC PowerPact H Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Schneider Electric Square D HJA260702 is a 2-pole PowerPact H-frame molded case circuit breaker engineered to provide dependable protection against overloads and short circuits. Rated for 70A and 600VAC, it offers a breaking capacity of up to 25kA at 600VAC and features thermal-magnetic trip technology for precise circuit protection. Designed for commercial and industrial distribution systems, the HJA260702 ensures efficient performance and easy integration with I-Line panelboards.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric \/ Square D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHJA260702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerPact H-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600VAC \/ 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100kA @ 240VAC \/ 65kA @ 480VAC \/ 25kA @ 600VAC \/ 20kA @ 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In (Line), Mechanical Lugs (Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 14–3\/0 Aluminum\/Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-13°F to 158°F (-25°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, NOM, IEC, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload and Short Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Front Cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.4 x 4.09 x 3.4 in (163 x 104 x 86 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.9 lb (2.2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eHJA260702\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"1074\" data-start=\"590\"\u003eThe HJA260702 is part of Schneider Electric’s PowerPact H-frame series, known for its compact design and high interrupting performance. Built with dual-break rotating contacts, it minimizes peak current during faults, enhancing equipment safety and system reliability. The breaker uses an I-Line plug-in connection on the line side and mechanical lugs on the load side, simplifying installation and maintenance in panelboard applications. Certified under UL, CSA, NOM, and IEC standards, the HJA260702 provides consistent protection for low-voltage power distribution systems in demanding environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal-Magnetic Trip Unit: Provides long-time and instantaneous trip protection against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated up to 100kA at 240VAC and 25kA at 600VAC for reliable fault interruption.\u003c\/li\u003e\n\u003cli\u003eCompact H-Frame Design: Optimized for space-saving installation in I-Line panels and switchboards.\u003c\/li\u003e\n\u003cli\u003eDual-Break Contact System: Reduces peak let-through current for improved equipment safety.\u003c\/li\u003e\n\u003cli\u003eWide Operating Temperature Range: Functions reliably from -25°C to 70°C (-13°F to 158°F).\u003c\/li\u003e\n\u003cli\u003eGlobal Standards Compliance: UL 489, CSA, NOM, IEC 60947-2, and CE certifications ensure worldwide usability.\u003c\/li\u003e\n\u003cli\u003eVersatile Wire Compatibility: Supports AWG 14 to AWG 3\/0 aluminum or copper conductors.\u003c\/li\u003e\n\u003cli\u003eFront-Mounted Controls: Includes toggle actuator and push-to-trip button for convenient operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HJA260702 delivers the reliability and precision required for safe, high-performance electrical distribution and protection in commercial and industrial systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":49105083072768,"sku":"HJA260702","price":4996.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/HJA260702-new-1.jpg?v=1785539731","url":"https:\/\/alotechparts.com\/products\/hja260702-schneider-electric-square-d-70a-2-pole-600vac-powerpact-h-molded-case-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}