{"product_id":"grx-3102-au-lutron-grafik-eye-2-zone-preset-lighting-control-220240-v","title":"GRX-3102-AU | Lutron GRAFIK Eye® 2-Zone Preset Lighting Control, 220‑240 V","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe GRX-3102-AU is a 2-zone preset lighting control unit in Lutron’s GRAFIK Eye® 3000 Series designed for controlling lighting zones with configurable presets. It is suited for 220–240 V electrical systems common in Australia and other AU-region installations and offers reliable performance for small-scale architectural lighting control.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 479.906px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22.2px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 32.5815%; text-align: left; height: 22.2px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 67.0426%; height: 22.2px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.2px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 32.5815%; text-align: left; height: 22.2px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 67.0426%; height: 22.2px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eLutron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.2px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 22.2px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 22.2px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003ePreset Dimming Control Systems\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.2px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 22.2px;\"\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 22.2px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eGRX-3102-AU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.2px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 22.2px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 22.2px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e2‑Zone Architectural Lighting Control Unit\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.2px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 22.2px;\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 22.2px;\"\u003e\u003cspan\u003eGRAFIK Eye® 3000 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.2px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 22.2px;\"\u003e\u003cspan\u003eInput Power\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 22.2px;\"\u003e\u003cspan\u003e220–240 V AC, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.475px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 20.475px;\"\u003e\u003cspan\u003eZone Capacity\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 20.475px;\"\u003e\u003cspan\u003e1,200 VA per zone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1125px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 21.1125px;\"\u003e\u003cspan\u003eUnit Total Capacity\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 21.1125px;\"\u003e\u003cspan\u003e1,600 VA\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.475px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 20.475px;\"\u003e\u003cspan\u003eNumber of Zones\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 20.475px;\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.475px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 20.475px;\"\u003e\u003cspan\u003eLoad Types\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 20.475px;\"\u003e\u003cspan\u003eIncandescent, magnetic LV, neon\/cold cathode, ELV transformer, HID\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.1625px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 22.1625px;\"\u003e\u003cspan\u003ePreset Scenes\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 22.1625px;\"\u003e\u003cspan\u003e4 onboard + 12 via wallstation\/control interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1125px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 21.1125px;\"\u003e\u003cspan\u003eFade Time Range\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 21.1125px;\"\u003e\u003cspan\u003eInstant to 60 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.475px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 20.475px;\"\u003e\u003cspan\u003ePower-Failure Memory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 20.475px;\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.475px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 20.475px;\"\u003e\u003cspan\u003eWiring Connections\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 20.475px;\"\u003e\u003cspan\u003eClass 2\/PELV low-voltage control wiring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 39.1875px;\"\u003e\u003cspan\u003eWallstation\/Interface Capacity\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 39.1875px;\"\u003e\u003cspan\u003eUp to 8 control units, up to 16 control points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 19.5938px;\"\u003e\u003cspan\u003eSurge\/ESD Protection\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 19.5938px;\"\u003e\u003cspan\u003eIEC 61000‑4‑2, ANSI\/IEEE C62.41\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 19.5938px;\"\u003e\u003cspan\u003eDimensions (WxHxD)\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 19.5938px;\"\u003e\u003cspan\u003e141 mm × 116 mm × 57 mm (5.56″ × 4.56″ × 2.25″)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 19.5938px;\"\u003e\u003cspan\u003eRequired Wallbox\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 19.5938px;\"\u003e\u003cspan\u003eTwo‑gang, ≥89 mm deep\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 39.1875px;\"\u003e\u003cspan\u003eOperating Temp\/Humidity\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 39.1875px;\"\u003e\u003cspan\u003e0‑40 °C, ≤90% non‑condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.5875px;\"\u003e\n\u003cth style=\"width: 32.5815%; text-align: left; height: 20.5875px;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 67.0426%; height: 20.5875px;\"\u003e\u003cspan\u003e~1.3 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About GRX-3102-AU\u003c\/h4\u003e\n\u003cp\u003eThe GRX-3102-AU is a 2-zone control unit for preset lighting scenes, delivering up to 1,200 W\/VA per zone and a combined capacity of 1,600 W\/VA at 220–240 V input power. It supports direct switching and dimming of incandescent, magnetic low-voltage, neon\/cold cathode, and ELV transformer loads; HID loads also supported. Installation requires a two‑gang wallbox with at least 89 mm depth and operates within standard ambient indoor conditions. The unit includes built‑in fade timing, power‑failure memory, and connects via Class 2 (PELV) wiring to wallstations and control interfaces.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDual‑Zone Control: Manages up to two independent lighting zones with individual control.\u003c\/li\u003e\n\u003cli\u003eHigh Power Handling: Supports 1,200 W\/VA per zone; 1,600 W\/VA total per unit on 220–240 V systems.\u003c\/li\u003e\n\u003cli\u003ePreset Scenes: Offers four onboard preset scenes plus off, with room for twelve additional scenes via external wallstations or interfaces.\u003c\/li\u003e\n\u003cli\u003eSmooth Fade Transitions: Adjustable fade times from immediate up to 60 minutes per scene.\u003c\/li\u003e\n\u003cli\u003ePower-Failure Memory: Automatically restores lights to previous levels and retains scene settings during outages.\u003c\/li\u003e\n\u003cli\u003eDirect Load Compatibility: Handles incandescent, magnetic low-voltage, neon\/cold cathode, ELV systems, and HID loads.\u003c\/li\u003e\n\u003cli\u003eRobust Electrical Standards: Meets IEC and ANSI\/IEEE surge and ESD standards for reliable operation.\u003c\/li\u003e\n\u003cli\u003eCompact Mounting Form: Fits standard two-gang wallbox with minimal spacing requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe GRX-3102-AU delivers the reliability and precision required for compact, preset-based lighting control in architectural or residential environments.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Lutron","offers":[{"title":"Default Title","offer_id":49105282892032,"sku":"GRX-3102-AU","price":1464.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_ed2d8417-bbcd-4d69-9b53-72e6095762ca.webp?v=1785544029","url":"https:\/\/alotechparts.com\/products\/grx-3102-au-lutron-grafik-eye-2-zone-preset-lighting-control-220240-v","provider":"Alo Tech Solutions","version":"1.0","type":"link"}