{"product_id":"gfps-6rb-gamewell-fci-replacement-board-for-gfps-6-nac-expander","title":"GFPS-6RB | Gamewell-FCI Replacement Board for GFPS-6 NAC Expander","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Gamewell-FCI GFPS-6RB is a replacement board designed for the GFPS-6 NAC Expander \/ Power Supply, restoring full functionality to notification appliance circuits in fire alarm systems. It supports 6 amps of regulated 24VDC output, integrated synchronization, and built-in battery charging capability.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 450.8px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003eGamewell-FCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003eGFPS-6RB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003eReplacement Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 39.2px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 39.2px;\"\u003eReplacement circuit board for GFPS-6 NAC Expander \/ Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003e24 VDC regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 39.2px;\"\u003e\u003cstrong\u003eTotal Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 39.2px;\"\u003e6.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eOutput Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003eFour NACs: 4 Class B, 2 Class A, or 1 Class A + 2 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eCurrent per Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003e3.0 A max per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003eContinuous auxiliary 24 VDC output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003e2 inputs, configurable as 2 Class B or 2 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 39.2px;\"\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 39.2px;\"\u003eBuilt-in sync for System Sensor, Gentex, Wheelock, AMSECO, and Faraday\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eBattery Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003eSupports up to 35 Ah batteries; 7 Ah maximum in cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 39.2px;\"\u003e\u003cstrong\u003eTrouble Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 39.2px;\"\u003eLED indicators and Form-C contacts for AC loss, battery fault, ground fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003eGFPS-6, FireForce 6, and SNAC-6 power supply units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003eUL Listed fire alarm accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.338%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.3472%; height: 19.6px;\"\u003e1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eGFPS-6RB\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe GFPS-6RB is a factory replacement board developed by Gamewell-FCI for use with the GFPS-6 NAC Expander \/ Power Supply and compatible units such as FireForce 6 and SNAC-6. It restores the expander’s full capacity of 6 amps at 24 VDC for notification appliances while retaining built-in synchronization for major strobe and horn manufacturers. The board also includes a battery charger that supports up to 35 Ah backup batteries, ensuring reliability during power loss. With DIP switch programmability, trouble monitoring features, and UL listing, the GFPS-6RB maintains compliance and reliability in life safety systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect replacement functionality: Specifically engineered to replace the original circuit board in GFPS-6, FireForce 6, and SNAC-6 units, restoring complete operation.\u003c\/li\u003e\n\u003cli\u003eHigh current capacity: Provides up to 6 amps of regulated 24VDC output, supporting multiple notification appliances across supervised circuits.\u003c\/li\u003e\n\u003cli\u003eFlexible circuit configuration: Includes four outputs configurable as 4 Class B, 2 Class A, or a mixed configuration, offering installation flexibility.\u003c\/li\u003e\n\u003cli\u003eBuilt-in synchronization: Supports System Sensor, Gentex, Wheelock, AMSECO, and Faraday appliances for code-compliant signaling.\u003c\/li\u003e\n\u003cli\u003eAuxiliary 24VDC output: Provides an additional continuous output for powering compatible system devices.\u003c\/li\u003e\n\u003cli\u003eBattery charging support: Features an integrated charger capable of maintaining up to 35 Ah batteries, with 7 Ah batteries accommodated within the cabinet.\u003c\/li\u003e\n\u003cli\u003eComprehensive trouble monitoring: Equipped with LED indicators and Form-C trouble relays to report AC loss, ground fault, and battery issues.\u003c\/li\u003e\n\u003cli\u003eUL Listed compliance: Certified as a fire alarm accessory, ensuring safety and reliability for use in commercial fire protection systems.\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight: At just 1 lb, the replacement board is easy to handle and install without adding bulk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe GFPS-6RB delivers the reliability and precision required to restore NAC expander and power supply functionality in Gamewell-FCI fire alarm systems.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":49105174495488,"sku":"GFPS-6RB","price":1439.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/gfps-6rb_new_edited.jpg?v=1785541847","url":"https:\/\/alotechparts.com\/products\/gfps-6rb-gamewell-fci-replacement-board-for-gfps-6-nac-expander","provider":"Alo Tech Solutions","version":"1.0","type":"link"}