{"product_id":"fx-5r-edwards-signaling-5-zone-conventional-fire-alarm-control-panel-120-vac-24-vdc","title":"FX-5R | Edwards Signaling 5-Zone Conventional Fire Alarm Control Panel, 120 VAC, 24 VDC","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Edwards Signaling FX-5R is a 5-zone conventional fire alarm control panel designed for reliable fire detection and notification in commercial and institutional applications. This steel-constructed unit supports Class B IDCs and NACs, with the option to convert to Class A circuits, ensuring flexible installation and dependable operation. With integrated features such as CleanMe and drift compensation, the FX-5R reduces false alarms and extends detector life.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdwards Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFX-5R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-Zone Conventional Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFX Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 IDCs (Class B, convertible to Class A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 NACs (Class B, convertible to Class A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Power Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 A per panel, 2 A per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5 in H × 14.25 in W × 3.75 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI\/UL 864 9th Edition, CSFM Approved, FDNY Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eFX-5R\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe FX-5R is part of the Edwards FX Series, which includes conventional fire alarm panels built to meet ANSI\/UL 864 9th Edition standards. It is equipped with five initiating device circuits and two notification appliance circuits, both convertible to Class A configurations for added system resilience. The panel provides 3.5A of NAC power and includes features such as zone-level programmability, annunciation, and synchronization with compatible notification appliances. Its rugged steel housing, LCD display, and compatibility with serial annunciator and relay modules make it suitable for a wide range of fire protection systems in mid-sized facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFive Initiating Device Circuits: Supports up to five Class B IDCs, convertible to Class A.\u003c\/li\u003e\n\u003cli\u003eTwo Notification Appliance Circuits: Each Class B, with option to convert to Class A for enhanced reliability.\u003c\/li\u003e\n\u003cli\u003e3.5A NAC Power Supply: Provides sufficient capacity for multiple notification appliances.\u003c\/li\u003e\n\u003cli\u003eCleanMe and Drift Compensation: Maintains detector sensitivity and reduces nuisance alarms.\u003c\/li\u003e\n\u003cli\u003eProgrammable Operation: Allows zone and NAC customization directly from the front panel.\u003c\/li\u003e\n\u003cli\u003eIntegrated DACT Option: Enables upload\/download capability and PC programming.\u003c\/li\u003e\n\u003cli\u003eSteel Cabinet Construction: Ensures durability and long service life in demanding environments.\u003c\/li\u003e\n\u003cli\u003eUL and CSFM Approved: Meets industry safety standards for fire alarm systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FX-5R delivers the reliability and flexibility required for professional fire detection and alarm installations.\u003c\/p\u003e","brand":"Edwards Signaling","offers":[{"title":"Default Title","offer_id":49105211195648,"sku":"FX-5R","price":992.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_5266f370-5695-493b-892e-84f82b833d0a.webp?v=1785542607","url":"https:\/\/alotechparts.com\/products\/fx-5r-edwards-signaling-5-zone-conventional-fire-alarm-control-panel-120-vac-24-vdc","provider":"Alo Tech Solutions","version":"1.0","type":"link"}