{"product_id":"fnp-1127-slc-hochiki-single-loop-expander-card-for-addressable-fire-alarm-panels","title":"FNP-1127-SLC | Hochiki Single Loop Expander Card for Addressable Fire Alarm Panels","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Hochiki FNP-1127-SLC is a single-loop expander card designed for use with Hochiki fire alarm control panels. It increases system capacity by adding one additional SLC (Signaling Line Circuit), allowing connection of more addressable devices within the same panel.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 391.876px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eHochiki\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eFNP-1127-SLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eLoop Expander Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eAddressable loop expansion module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eAdds one additional SLC (Signaling Line Circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eHochiki FNP-1127 series control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eHochiki intelligent addressable detectors and modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 39.1875px;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 39.1875px;\"\u003eHochiki digital addressable loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eInternal plug-in board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003ePanel-mounted, factory-configured or field-installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eSupplied via host control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003ePCB electronic card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eFire alarm system expansion and device capacity increase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eIndoor, panel enclosure protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eUL listed and NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003eStandard module size (approx. 4\" × 3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.7018%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 69.079%; height: 19.5938px;\"\u003e0.5 lbs (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About FNP-1127-SLC\u003c\/h4\u003e\n\u003cp\u003eThe FNP-1127-SLC is part of Hochiki’s modular expansion architecture, built to enhance the scalability and flexibility of addressable fire alarm systems. Each expander card supports an additional SLC loop, enabling the control panel to monitor and control more detectors, modules, and notification devices. Designed for simple plug-in installation, the card integrates seamlessly with Hochiki control panels such as the FNP-1127 series. Its microprocessor-based communication ensures reliable device supervision, rapid response, and compatibility with Hochiki’s intelligent device protocol. Ideal for commercial, institutional, and industrial installations, the FNP-1127-SLC provides a cost-effective method for expanding system capacity without requiring additional control panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSingle SLC Expansion: Adds one additional addressable loop to compatible Hochiki panels.\u003c\/li\u003e\n\u003cli\u003ePlug-In Design: Installs directly into the main control board without complex wiring.\u003c\/li\u003e\n\u003cli\u003eAddressable Device Support: Accommodates Hochiki intelligent detectors and modules.\u003c\/li\u003e\n\u003cli\u003eReliable Communication: Uses Hochiki’s digital protocol for fast and accurate device supervision.\u003c\/li\u003e\n\u003cli\u003eModular Scalability: Expands system capacity as building requirements grow.\u003c\/li\u003e\n\u003cli\u003ePanel Compatibility: Designed for FNP-1127 series and similar Hochiki control panels.\u003c\/li\u003e\n\u003cli\u003eHigh Stability: Microprocessor-controlled circuitry ensures dependable operation.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Meets standards for fire alarm system components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FNP-1127-SLC delivers the reliability and precision required for intelligent system expansion in Hochiki addressable fire alarm networks.\u003c\/p\u003e","brand":"HOCHIKI","offers":[{"title":"Default Title","offer_id":49105155850496,"sku":"FNP-1127-SLC","price":990.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/fnp-1127-slc_edited.jpg?v=1785541504","url":"https:\/\/alotechparts.com\/products\/fnp-1127-slc-hochiki-single-loop-expander-card-for-addressable-fire-alarm-panels","provider":"Alo Tech Solutions","version":"1.0","type":"link"}