{"product_id":"fci2017-u1-siemens-500-point-periphery-board-for-fire-alarm-systems","title":"FCI2017-U1 | Siemens 500-Point Periphery Board for Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens FCI2017-U1 is a periphery board designed for use in Siemens fire control panels, including voice alarm systems. This 500-point PCB provides monitoring, control, and power distribution for detectors, notification devices, and auxiliary modules. With thermal protection and built-in NAC circuits, the FCI2017-U1 ensures reliable system operation and connectivity in complex fire alarm setups.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBreaker Panels and Load Centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCI2017-U1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrical Load Centers \u0026amp; Panel Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e504 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Circuit Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3A per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5A, 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports up to 100 Ah batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFP2011 (170W), FP2012 (300W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded for external device control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReset Button\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS100 Reset periphery board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 circuits for detectors and drivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted in Siemens enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, UL Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e FCI2017-U1\u003c\/h4\u003e\n\u003cp\u003eThe FCI2017-U1 is part of the Siemens periphery board family, specifically engineered for panels supporting up to 504 device points. It features a modular design with dedicated terminals for power supplies, battery connections, and NAC circuits. The board is compatible with both class A and class B notification appliance circuits and integrates relays, detector circuits, and reset functions. Its robust construction ensures stable performance in fire alarm systems, while providing easy expansion and fault monitoring capabilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Capacity: Supports up to 504 device points for extensive fire system coverage.\u003c\/li\u003e\n\u003cli\u003eNAC Circuit Integration: Provides up to 3A per NAC circuit for class A or class B configurations.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Output: 24V DC output to power remote modules or internal devices.\u003c\/li\u003e\n\u003cli\u003eBattery Management: Built-in charger and switchover for AC fail or brownout conditions.\u003c\/li\u003e\n\u003cli\u003eDetector Support: Dedicated circuits for reliable connection of smoke and heat detectors.\u003c\/li\u003e\n\u003cli\u003eRelay Integration: Multiple relay terminals for external device control.\u003c\/li\u003e\n\u003cli\u003eReset Function: S100 reset button allows system-wide periphery board resets.\u003c\/li\u003e\n\u003cli\u003eExpansion Ready: Supports leased line\/city tie operation and additional NAC circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FCI2017-U1 delivers the reliability and precision required for managing complex fire alarm and voice alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105128915200,"sku":"FCI2017-U1","price":3564.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-10-18_20.48.49.png?v=1785540925","url":"https:\/\/alotechparts.com\/products\/fci2017-u1-siemens-500-point-periphery-board-for-fire-alarm-systems","provider":"Alo Tech Solutions","version":"1.0","type":"link"}