{"product_id":"fa340201021-square-d-by-schneider-electric-3-pole-20a-molded-case-circuit-breaker","title":"FA340201021 | Square D by Schneider Electric 3-Pole 20A Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"376\" data-start=\"85\"\u003eThe Square D by Schneider Electric FA340201021 is a three-pole molded case circuit breaker designed for dependable thermal-magnetic protection in commercial and industrial power distribution systems. It is rated for 20 amps at 480 VAC and provides long-time and instantaneous trip functions to protect against overloads and short circuits. This breaker is engineered for I-Line installation with lug connections on the load side.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 372.282px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eSquare D by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eFA340201021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eFA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eMolded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eF-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003e480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eInterrupting Rating (240 VAC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003e25 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eInterrupting Rating (480 VAC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003e18 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eLine Side Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eI-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eLoad Side Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003ePower Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 38.1086%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.6721%; height: 19.5938px;\"\u003e6.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e FA340201021\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe FA340201021 is part of Square D by Schneider Electric’s FA Series within the F-Frame molded case circuit breaker family. It is designed for three-phase electrical systems operating at up to 480 volts and provides consistent protection using thermal-magnetic trip technology. The breaker supports I-Line mounting on the line side for efficient panelboard integration while using lugs on the load side for secure field wiring. Its construction is suited for use in power distribution equipment where compact design and reliable interrupting performance are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFA Series F-Frame Design: Engineered for reliable branch and feeder circuit protection.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip Unit: Provides long-time and instantaneous fault protection.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Suitable for three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003e20 Amp Current Rating: Designed for lower-load distribution circuits.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated 25 kA at 240 VAC and 18 kA at 480 VAC.\u003c\/li\u003e\n\u003cli\u003eI-Line Line-Side Connection: Enables fast, secure installation in compatible panelboards.\u003c\/li\u003e\n\u003cli\u003eLug Load-Side Termination: Supports dependable downstream electrical connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FA340201021 delivers the reliability and precision required for safe circuit protection in three-phase power distribution applications.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":49104988766464,"sku":"FA340201021","price":1953.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_775da6c0-4fb1-4097-938e-ff30027243fb.webp?v=1785537485","url":"https:\/\/alotechparts.com\/products\/fa340201021-square-d-by-schneider-electric-3-pole-20a-molded-case-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}