{"product_id":"edb14030epd-square-d-30a-1-pole-277-vac-molded-case-circuit-breaker-with-equipment-protection","title":"EDB14030EPD | Square D 30A 1-Pole 277 VAC Molded Case Circuit Breaker with Equipment Protection","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Square D EDB14030EPD is a 1-pole, 30-amp molded case circuit breaker designed for use in lighting and power distribution panelboards. It features thermal-magnetic protection and a bolt-on mounting configuration for secure installation. This breaker provides dependable overload and short-circuit protection in commercial and industrial electrical systems operating at 277 VAC.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEDB14030EPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEDB Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e277 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEquipment Protection Device (30 mA Ground Fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 14–6 Cu \/ AWG 12–4 Al\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermoset Composite Resin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Certified, NOM 117, Federal Spec W-C-375B\/GEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLighting, HID, HACR, Switching Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMexico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (Approx.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.66 in H × 1.96 in W × 4.05 in D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eEDB14030EPD\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"590\" data-end=\"1074\" class=\"\"\u003eThe EDB14030EPD is part of the Square D EDB Series, developed by Schneider Electric for efficient circuit protection in NF panelboards and other compatible systems. It includes an integrated equipment protection device (EPD) and offers 30 mA ground fault protection to ensure personnel and equipment safety. Built with a thermoset molded case, the breaker withstands harsh electrical environments while maintaining consistent trip performance. With UL, CSA, and NOM certifications, it meets rigorous international standards for reliability and safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal-Magnetic Trip Unit: Provides long-time and instantaneous trip functions for effective overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eIntegrated Ground Fault Protection: Includes a 30 mA equipment protection device for added electrical safety.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Rating: Rated for up to 18 kA at 480V, supporting a wide range of commercial applications.\u003c\/li\u003e\n\u003cli\u003eBolt-On Mounting: Ensures secure attachment and stable operation within Square D NF panelboards.\u003c\/li\u003e\n\u003cli\u003eDurable Housing: Thermoset composite construction resists heat and impact for extended service life.\u003c\/li\u003e\n\u003cli\u003eVersatile Conductor Range: Accepts copper or aluminum conductors (AWG 14–6 Cu \/ AWG 12–4 Al).\u003c\/li\u003e\n\u003cli\u003eCertified Compliance: UL Listed, CSA Certified, NOM 117 compliant, and HACR rated for HVAC applications.\u003c\/li\u003e\n\u003cli\u003eTemperature Calibrated: Designed for 40°C ambient conditions, ensuring stable thermal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EDB14030EPD delivers the reliability and precision required for safe and efficient power distribution in lighting and equipment protection systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":49105111023872,"sku":"EDB14030EPD","price":1245.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/EDB14030EPD-new-1.jpg?v=1785540501","url":"https:\/\/alotechparts.com\/products\/edb14030epd-square-d-30a-1-pole-277-vac-molded-case-circuit-breaker-with-equipment-protection","provider":"Alo Tech Solutions","version":"1.0","type":"link"}