{"product_id":"czm-1b6-siemens-remote-conventional-zone-module","title":"CZM-1B6 | Siemens Remote Conventional Zone Module","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens CZM-1B6 is a remote conventional zone module designed for integration with Siemens fire alarm systems. Operating at 18–24.5 VDC, it provides supervised monitoring of conventional detection zones with a low current draw of 4 mA.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 352.8px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eFire \u0026amp; Life Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eCZM-1B6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eZone Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eRemote Conventional Zone Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003e18–24.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003e4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003e35 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eMonitors Conventional Detection Zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eOpen\/Short Circuit and Fault Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eSiemens Fire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eModule Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eUL Listed (when used with compatible panels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eStandard Module Size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eStandard PCB Finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003eDiscontinued by Manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 29.0522%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.8147%; height: 19.6px;\"\u003e0.5 lb (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About CZM-1B6\u003c\/h4\u003e\n\u003cp\u003eThe CZM-1B6 is part of Siemens’ modular fire alarm components, engineered to interface conventional detection devices with addressable Siemens control panels. It supervises zone wiring for open, short, and fault conditions while providing reliable communication back to the system. Compact and panel-mountable, this module allows facilities to integrate legacy or conventional detectors into newer Siemens fire alarm installations. Though discontinued by the manufacturer, the CZM-1B6 remains important for maintaining or repairing legacy systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote Zone Module: Provides conventional zone monitoring within Siemens systems.\u003c\/li\u003e\n\u003cli\u003e18–24.5 VDC Operation: Low-voltage, supervised input for reliable performance.\u003c\/li\u003e\n\u003cli\u003eLow Current Draw: Consumes only 4 mA, reducing system load.\u003c\/li\u003e\n\u003cli\u003eSupervised Monitoring: Detects open circuits, shorts, and wiring faults.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Interfaces conventional detection devices with Siemens fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Fits within control panel enclosures or auxiliary housings.\u003c\/li\u003e\n\u003cli\u003eDiscontinued Model: Still available for service and legacy system support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CZM-1B6 delivers the reliability and precision required for conventional zone integration in Siemens fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105185145088,"sku":"CZM-1B6","price":1468.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/08_05_2024_16_32_35_CZM_1B6_Siemens.jpg?v=1785542089","url":"https:\/\/alotechparts.com\/products\/czm-1b6-siemens-remote-conventional-zone-module","provider":"Alo Tech Solutions","version":"1.0","type":"link"}