{"product_id":"c7232a1016-honeywell-wall-mount-co2-sensor","title":"C7232A1016 | Honeywell Wall-Mount CO₂ Sensor","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Honeywell C7232A1016 is a wall-mount carbon dioxide (CO₂) sensor with a 0–2000 ppm measurement range and selectable analog outputs. It provides accurate air quality monitoring for applications such as greenhouses, laboratories, food processing, and indoor environmental control.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 411.47px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003eGas \u0026amp; Specialty Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003eC7232A1016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003eCO₂ Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003e0–2000 ppm ±5% and ±50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003e±30 ppm + 2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003e0\/2–10 VDC @ 5kΩ, 0\/4–20 mA @ 500Ω (jumper selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eRelay Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003eSPST, 1A @ 50 VAC\/24 VDC, N.O., closes at 800 ppm (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003e24 VAC ±20% @ 3 VA, 50\/60 Hz; 24 VDC ±20% @ 125 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003e2 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eCalibration Interval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003ePressure Dependence\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003e1.4% change per 0.15 psig deviation from 14.5 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 39.1875px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 39.1875px;\"\u003e32°F to 122°F (0°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003e0–95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003eWall: NEMA 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eFlammability Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003eUL95-5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eWiring Terminations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003e20 AWG, 8\" and 6\" cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eMount Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003eWall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8824%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.2399%; height: 19.5938px;\"\u003e0.4 lb (0.18 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eC7232A1016\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"1098\" data-start=\"460\"\u003eThe C7232A1016 is part of Honeywell’s gas and specialty sensor line, engineered for reliable CO₂ detection in commercial, agricultural, and industrial environments. It features selectable 0\/2–10 VDC and 0\/4–20 mA output signals, an SPST relay for direct control, and a wall-mount NEMA 1 enclosure. Powered by 24 VAC or VDC, it offers ±30 ppm + 2% accuracy with a five-year calibration interval, minimizing maintenance requirements. Designed without a display for simplified integration, this sensor ensures fast response and consistent performance in applications requiring precise indoor air quality monitoring.\u003c\/p\u003e\n\u003cp data-end=\"1119\" data-start=\"1100\"\u003e\u003cstrong data-end=\"1117\" data-start=\"1100\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2048\" data-start=\"1120\"\u003e\n\u003cli data-end=\"1244\" data-start=\"1120\"\u003e\n\u003cp data-end=\"1244\" data-start=\"1122\"\u003e\u003cstrong data-end=\"1151\" data-start=\"1122\"\u003eWide CO₂ detection range:\u003c\/strong\u003e Measures from 0–2000 ppm with ±30 ppm + 2% accuracy for dependable air quality monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1366\" data-start=\"1245\"\u003e\n\u003cp data-end=\"1366\" data-start=\"1247\"\u003e\u003cstrong data-end=\"1277\" data-start=\"1247\"\u003eSelectable output signals:\u003c\/strong\u003e Supports 0\/2–10 VDC and 0\/4–20 mA outputs, jumper-selectable for system compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1503\" data-start=\"1367\"\u003e\n\u003cp data-end=\"1503\" data-start=\"1369\"\u003e\u003cstrong data-end=\"1395\" data-start=\"1369\"\u003eIntegrated SPST relay:\u003c\/strong\u003e Shipped normally open, closes at 800 ppm (adjustable) for direct load switching up to 1A @ 50 VAC\/24 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1604\" data-start=\"1504\"\u003e\n\u003cp data-end=\"1604\" data-start=\"1506\"\u003e\u003cstrong data-end=\"1529\" data-start=\"1506\"\u003eFast response time:\u003c\/strong\u003e Provides readings within 2 minutes for responsive environmental control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1697\" data-start=\"1605\"\u003e\n\u003cp data-end=\"1697\" data-start=\"1607\"\u003e\u003cstrong data-end=\"1634\" data-start=\"1607\"\u003eLow maintenance design:\u003c\/strong\u003e Five-year calibration interval reduces operational downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1813\" data-start=\"1698\"\u003e\n\u003cp data-end=\"1813\" data-start=\"1700\"\u003e\u003cstrong data-end=\"1729\" data-start=\"1700\"\u003eEnvironmental durability:\u003c\/strong\u003e Operates from 32°F to 122°F and 0–95% RH non-condensing for versatile indoor use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1935\" data-start=\"1814\"\u003e\n\u003cp data-end=\"1935\" data-start=\"1816\"\u003e\u003cstrong data-end=\"1850\" data-start=\"1816\"\u003ePressure-compensated accuracy:\u003c\/strong\u003e Adjusts for 1.4% change per 0.15 psig deviation to maintain measurement integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2048\" data-start=\"1936\"\u003e\n\u003cp data-end=\"2048\" data-start=\"1938\"\u003e\u003cstrong data-end=\"1959\" data-start=\"1938\"\u003eRugged enclosure:\u003c\/strong\u003e NEMA 1 wall-mount housing with UL95-5V flammability rating for safety and reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2204\" data-start=\"2050\"\u003eThe C7232A1016 delivers the reliability, accuracy, and versatility required for CO₂ monitoring in commercial, industrial, and agricultural applications.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105252778240,"sku":"C7232A1016","price":757.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/c7232a1016_uqj00fwb7rbcrppe.jpg?v=1785543542","url":"https:\/\/alotechparts.com\/products\/c7232a1016-honeywell-wall-mount-co2-sensor","provider":"Alo Tech Solutions","version":"1.0","type":"link"}