{"product_id":"be120h-siemens-20a-1-pole-120v-ground-fault-circuit-breaker-22kaic-bolt-on","title":"BE120H | Siemens 20A 1-Pole 120V Ground Fault Circuit Breaker 22kAIC Bolt-On","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens BE120H is a 1-Pole Ground Fault Circuit Breaker designed for reliable protection of electrical circuits against overloads, short circuits, and ground faults. With a current rating of 20 Amps and 120 VAC voltage capacity, this breaker provides dependable safety in residential and commercial electrical systems. It features a 22kAIC interrupting rating and a bolt-on mounting configuration, ensuring strong performance and secure installation in Siemens panelboards.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBE120H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround Fault Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22kAIC at 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGFCI (Ground Fault Circuit Interrupter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanelboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, NOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14–10 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor Use With\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens P1 Panelboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 in x 4 in x 5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.243 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eBE120H\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe BE120H is part of Siemens’ BL Series molded case circuit breakers, known for their precision engineering and compact design. It incorporates thermal-magnetic protection that provides both long-time and instantaneous trip functions for comprehensive circuit defense. The breaker’s GFCI (Ground Fault Circuit Interrupter) technology quickly disconnects power when a ground fault is detected, preventing electrical shock and equipment damage. Designed for use with Siemens P1 panelboards, the BE120H offers a durable, UL- and CSA-certified solution for code-compliant installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround Fault Protection: Detects and interrupts ground faults to safeguard personnel and connected equipment.\u003c\/li\u003e\n\u003cli\u003eThermal Magnetic Trip: Provides accurate overload and short-circuit protection through dual trip mechanisms.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Rating: Rated 22kAIC at 120V for superior fault-clearing capability.\u003c\/li\u003e\n\u003cli\u003eBolt-On Connection: Ensures stable electrical contact and easy installation into Siemens panelboards.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Space-saving molded case suitable for high-density electrical systems.\u003c\/li\u003e\n\u003cli\u003eUL, CSA, and NOM Approved: Certified for use across multiple regulatory standards.\u003c\/li\u003e\n\u003cli\u003eDurable Frame Construction: Type B frame provides robust protection in demanding electrical environments.\u003c\/li\u003e\n\u003cli\u003eTemperature Rated 40°C: Maintains consistent performance across standard ambient conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BE120H delivers the reliability and precision required for safe and consistent electrical protection in residential, commercial, and industrial panelboard applications.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105097031936,"sku":"BE120H","price":514.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/siemens_be120h.jpg?v=1785540115","url":"https:\/\/alotechparts.com\/products\/be120h-siemens-20a-1-pole-120v-ground-fault-circuit-breaker-22kaic-bolt-on","provider":"Alo Tech Solutions","version":"1.0","type":"link"}