{"product_id":"acps-2406-notifier-addressable-charging-power-supply","title":"ACPS-2406 | Notifier Addressable Charging Power Supply","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Notifier ACPS-2406 is an addressable 24 VDC power supply and battery charger that supports both notification appliances and auxiliary system loads. It features NAC synchronization, battery supervision, and selectable addressability for seamless system integration.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 557px; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 34.9219px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 34.9219px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 34.9219px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.4219px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 27.4219px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 27.4219px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eNotifier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.4219px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24.4219px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24.4219px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eFire Safety\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.2969px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 28.2969px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 28.2969px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eACPS-2406\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.7188px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 23.7188px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 23.7188px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eFire Alarm\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 33.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 33.1875px;\"\u003e\u003cspan\u003ePrimary Power Input\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 33.1875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e110–120 VAC, 50\/60 Hz, 2.7 A\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.1875px;\"\u003e\u003cspan\u003eDC Output Voltage\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.1875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e24 VDC regulated and power-limited\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 32.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 32.1875px;\"\u003eOutput Capacity\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 32.1875px;\"\u003e5.0 A continuous, 6.0 A alarm surge (1 hour UL rating)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eOutput Circuits\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e4 NACs (TB4–TB6), Class B or configurable as power outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 27.5938px;\"\u003eAuxiliary Power Output\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 27.5938px;\"\u003e24 VDC at 0.5 A (internal, J1 terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eResettable Power Output\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003eConfigurable at TB6–3 and TB6–4 with shared current limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.1875px;\"\u003eBattery Charging Range\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.1875px;\"\u003e7–25 AH sealed lead-acid batteries (via TB2, TB3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eMax Battery Charging Current\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e1.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 32.1875px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 32.1875px;\"\u003eWire Size Range\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 32.1875px;\"\u003e12–18 AWG (3.25–0.75 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24.1875px;\"\u003eAverage SLC Current\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24.1875px;\"\u003e1.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eSLC Resistance Limit\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e≤ 40\/50 Ohms to panel (LIB-200A\/400 max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eFuse Protection\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003eBattery fuse F2: 15 A, 3AB type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eLine Drop Tolerance\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003eUp to 2.4 VDC to last SLC device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eCompliance\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003eUL 864, NFPA 72, NEC Articles 300 \u0026amp; 760, Local Building Codes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.5625px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 20.5625px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 20.5625px;\"\u003e\u003cspan\u003e2.22 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eACPS-2406\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe ACPS-2406 is designed to expand the power capacity of Notifier fire alarm systems by providing up to 6.0 amps of regulated 24 VDC output. It is fully compatible with key Notifier control panels including AFP-100, AFP-200, AFP-300\/400, AFP-1010, AM2020, AFC-600, NFS-640, and NFS-3030. The unit operates in both FlashScan® and CLIP protocols, and can be configured to support four NACs or provide four-wire detector\/general-purpose power. Built-in strobe synchronization supports System Sensor SpectrAlert™ Series and other UL-listed devices when used uniformly across the system.\u003c\/p\u003e\n\u003cp\u003eIt includes an integral lead-acid battery charger for 7 to 25 AH batteries and supervises AC loss, battery faults, brownouts, and ground faults. With configurable output limits (5.0 A continuous, 6.0 A during alarm), and 0.5 A of auxiliary 24 VDC power available internally, the ACPS-2406 ensures consistent system operation even during emergency power transitions. Its SLC interface supports 5 to 13 addresses depending on configuration, and features LED indicators and fuse protection for streamlined diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAddressable and Protocol-Compatible: Works with FlashScan and CLIP-mode fire panels for flexible system architecture.\u003c\/li\u003e\n\u003cli\u003eMultiple Output Options: Supports up to 4 NACs or can be configured to power four-wire detectors or general loads.\u003c\/li\u003e\n\u003cli\u003eIntegrated Battery Charger: Supports 7–25 AH lead-acid batteries with 1.1 A charging current.\u003c\/li\u003e\n\u003cli\u003eNAC Synchronization Support: Built-in strobe synchronization for System Sensor, Wheelock, Gentex, and similar devices.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Power Output: Provides 24 VDC @ 0.5 A for use within the same cabinet.\u003c\/li\u003e\n\u003cli\u003eSystem Fault Monitoring: Detects brownouts, AC loss, battery faults, and ground faults.\u003c\/li\u003e\n\u003cli\u003eSelectable Addressing: Occupies between 5 and 13 SLC addresses depending on configuration.\u003c\/li\u003e\n\u003cli\u003eUniversal Zone Coder (UZC-256) Support: Enables Canadian temporal patterns for evacuation logic.\u003c\/li\u003e\n\u003cli\u003eUL and NFPA Certified: Conforms to UL 864 and NFPA 72 standards with support for NEC wiring codes.\u003c\/li\u003e\n\u003cli\u003eWide Wire Support and Safety Fusing: Accepts 12–18 AWG conductors and includes 15 A (F2) and 3AB fuses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ACPS-2406 delivers fully supervised addressable power with built-in battery charging and advanced output options for modern fire alarm networks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105315856640,"sku":"ACPS-2406","price":2516.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/1119327c64964fabbe83d3db1e3eb80e.jpg?v=1785544808","url":"https:\/\/alotechparts.com\/products\/acps-2406-notifier-addressable-charging-power-supply","provider":"Alo Tech Solutions","version":"1.0","type":"link"}