{"product_id":"787502-pilz-pnoz-xv2p-c-safety-relay-24vdc-time-delay","title":"787502 | Pilz PNOZ XV2P C Safety Relay 24VDC Time Delay","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"122\" data-end=\"397\"\u003eThe Pilz 787502 PNOZ XV2P C is a configurable safety relay designed for monitoring emergency stop circuits, safety gates, and limit switches. Operating on 24 VDC, it provides instantaneous and time-delayed safety outputs with selectable delay times up to 3 seconds.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003ePilz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003eSafety Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003e787502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003eTime-Delay Safety Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003ePNOZ X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003ePNOZ XV2P C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003e4.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003eSingle or dual-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003eE-stop pushbuttons, safety gates, limit switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eInstantaneous Safety Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003e2 × NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eDelayed Safety Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003e2 × NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eSelectable Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003e0.1 s to 3 s (multiple steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eStart Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003eAutomatic \/ monitored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003eCage clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eTerminal Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003ePlug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003eEN 60204-1, EN 62061, EN 954-1, VDE 0113-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003eCCC, cUL, GOST, TÜV, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 24.8744%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.7619%;\"\u003e0.78 lb (355 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e 787502\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 787502 is part of the Pilz PNOZ X series safety relays developed for reliable control of safety-related stop functions. It supports both instantaneous and time-delayed safety contacts, allowing controlled shutdown sequences to match machine safety requirements. The relay offers a wide range of selectable delay times up to 3 seconds, providing flexibility for different applications and risk assessments. Designed for DIN rail mounting with plug-in cage clamp terminals, it enables secure wiring and efficient installation in industrial control panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfigurable Time-Delay Safety Function: Provides selectable delay settings from 0.1 to 3 seconds to support controlled stop and restart sequences.\u003c\/li\u003e\n\u003cli\u003eDual Safety Output Types: Combines two instantaneous and two delayed normally open safety contacts for flexible safety circuit design.\u003c\/li\u003e\n\u003cli\u003eSingle or Dual-Channel Input Support: Enables use with various safety devices while meeting different safety architecture requirements.\u003c\/li\u003e\n\u003cli\u003e24 VDC Operation: Designed for standard low-voltage industrial safety control systems.\u003c\/li\u003e\n\u003cli\u003eCage Clamp Plug-In Terminals: Ensure secure, vibration-resistant wiring and faster installation or replacement.\u003c\/li\u003e\n\u003cli\u003eCompact DIN Rail Housing: Supports space-efficient mounting in modern control cabinets.\u003c\/li\u003e\n\u003cli\u003eCertified Safety Compliance: Approved to multiple international safety standards for use in safety-critical machine applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 787502 delivers the reliability and precision required for time-controlled safety switching in industrial automation and machine safety systems.\u003c\/p\u003e","brand":"Pilz","offers":[{"title":"Default Title","offer_id":49105029366016,"sku":"787502","price":539.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l960_31ac7fc7-261a-4d2d-881e-6d8362ceb2bf.webp?v=1785538358","url":"https:\/\/alotechparts.com\/products\/787502-pilz-pnoz-xv2p-c-safety-relay-24vdc-time-delay","provider":"Alo Tech Solutions","version":"1.0","type":"link"}