{"product_id":"700-nt-allen-bradley-industrial-pneumatic-timing-unit-for-bulletin-700-n","title":"700-NT | Allen-Bradley Industrial Pneumatic Timing Unit for Bulletin 700-N","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003eThe Allen-Bradley 700-NT is a pneumatic timing unit designed for use with Bulletin 700-N industrial relays. It features a standard ON-delay timing configuration with timed contacts and is easily convertible to OFF-delay mode, offering flexibility in time-based control applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 395.406px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 27px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 25.8226%; text-align: left; height: 27px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 73.8563%; height: 27px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 33.8125px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 25.8226%; text-align: left; height: 33.8125px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 73.8563%; height: 33.8125px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllen-Bradley \u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 31.625px;\"\u003e\n\u003cth style=\"width: 25.8226%; text-align: left; height: 31.625px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 31.625px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\u003cspan\u003eControls \u0026amp; Indicators\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 31.625px;\"\u003e\n\u003cth style=\"width: 25.8226%; text-align: left; height: 31.625px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 31.625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e700-NT\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.125px;\"\u003e\n\u003cth style=\"width: 25.8226%; text-align: left; height: 23.125px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 23.125px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eTime Delay Relay\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.9375px;\"\u003e\n\u003cth style=\"width: 25.8226%; height: 25.9375px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 25.9375px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eBulletin 700-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.1875px;\"\u003e\n\u003cth style=\"width: 25.8226%; height: 41.1875px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eTiming Mode (Default)\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 41.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan\u003eON-Delay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 25.8226%; height: 39.1875px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eContact Configuration\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 39.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e1 Normally Open (NO), 1 Normally Closed (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.1875px;\"\u003e\n\u003cth style=\"width: 25.8226%; height: 21.1875px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCompatibility\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 21.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e700-N Relays (2 to 4-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.75px;\"\u003e\n\u003cth style=\"width: 25.8226%; height: 21.75px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 21.75px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eOpen Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.8226%; text-align: left; height: 19.5938px;\"\u003ePower Requirement\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 19.5938px;\"\u003eNone (Pneumatic Operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 40.1875px;\"\u003e\n\u003cth style=\"width: 25.8226%; text-align: left; height: 40.1875px;\"\u003eStandards Compliance\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 40.1875px;\"\u003e\u003cspan\u003eUL, CUL, KC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.8226%; text-align: left; height: 19.5938px;\"\u003eApplication\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 19.5938px;\"\u003e\u003cspan\u003eTime-Delay Relay Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.8226%; text-align: left; height: 19.5938px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 73.8563%; height: 19.5938px;\"\u003e\u003cspan\u003e0.4200 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e700-NT\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 700-NT timing unit is specifically engineered for integration with the Allen-Bradley Bulletin 700-N relay series. It provides time-delay functionality using pneumatic actuation, eliminating the need for electrical power to operate the timer. The unit includes 1 normally open (NO) and 1 normally closed (NC) timed contact in its configuration and is delivered in ON-delay mode by default. This mode can be quickly changed to OFF-delay by adjusting internal components, offering dual functionality. The timing unit is designed as an open-type module, intended for installation inside protective enclosures. With compliance to UL, CUL, and KC standards, it ensures safe and dependable operation in industrial automation systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eON-Delay Operation (Standard): Timer delays the activation of output contacts after input signal is applied.\u003c\/li\u003e\n\u003cli\u003eConvertible to OFF-Delay Mode: Easily reconfigured to delay the deactivation of contacts upon removal of the control signal.\u003c\/li\u003e\n\u003cli\u003ePneumatic Operation: No external power supply required for timing function, ensuring intrinsic reliability.\u003c\/li\u003e\n\u003cli\u003e1 NO \/ 1 NC Timed Contacts: Supports both make and break delay logic for flexible system control.\u003c\/li\u003e\n\u003cli\u003eOpen-Type Construction: Designed for mounting within control panels or relay assemblies for environmental protection.\u003c\/li\u003e\n\u003cli\u003e700-N Relay Compatibility: Built to integrate seamlessly with 2- to 4-pole Bulletin 700-N relays.\u003c\/li\u003e\n\u003cli\u003eAdjustable Time Range: Offers a selectable time delay range (typically seconds to minutes, depending on the model).\u003c\/li\u003e\n\u003cli\u003eDurable Mechanical Design: Engineered for long life and consistent delay performance in demanding industrial applications.\u003c\/li\u003e\n\u003cli\u003eStandards Compliant: Meets CUL, KC, and UL requirements for industrial control timing devices.\u003c\/li\u003e\n\u003cli\u003eNo Electrical Noise: Pneumatic timing eliminates transient signals, ideal for sensitive circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 700-NT offers reliable, adjustable timing functionality for Bulletin 700-N relay systems, delivering flexibility in automation control with both ON- and OFF-delay capability.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":49105332240640,"sku":"700-NT","price":1292.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/shopping_73_40bce07b-6dee-4d6e-a71a-fc97cbecfcdd.webp?v=1785545073","url":"https:\/\/alotechparts.com\/products\/700-nt-allen-bradley-industrial-pneumatic-timing-unit-for-bulletin-700-n","provider":"Alo Tech Solutions","version":"1.0","type":"link"}