{"product_id":"51304362-150-honeywell-low-level-analog-input-multiplexer-processor","title":"51304362-150 | Honeywell Low Level Analog Input Multiplexer Processor","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003eThe Honeywell 51304362-150 is a Low Level Analog Input Multiplexer Processor (LLMux IOP) designed for use with TDC 3000 or Experion PKS systems. This processor supports up to 32 analog inputs for low-level signal acquisition and is optimized for thermocouples, RTDs, and millivolt-level sources.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 396.063px; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 32.75px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 32.75px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 32.75px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 31.3438px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 31.3438px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 31.3438px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.4844px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.4844px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.4844px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003ePLCs\/Machine Control\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 31.25px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 31.25px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 31.25px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e51304362-150\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 31.6875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 31.6875px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 31.6875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003ePC Board PLC\/Add-On Board\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 23.875px;\"\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 23.875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e32\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.8594px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 25.8594px;\"\u003eInput Scan Rate\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 25.8594px;\"\u003e32 samples per second\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.5px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 39.5px;\"\u003eSupported Signal Types\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 39.5px;\"\u003eThermocouple, RTD, Linear mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5625px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 28.5625px;\"\u003eCE Compliance\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 28.5625px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.5px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.5px;\"\u003eConformal Coating\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.5px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.0469px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.0469px;\"\u003eRedundancy\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.0469px;\"\u003e\u003cspan\u003eNot supported\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.75px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.75px;\"\u003eCompatible FTAs\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.75px;\"\u003e\u003cspan\u003eMU-TAMT02, MU-TAMT03 (with local CJR); MU-TAMT12, MU-TAMT13 (remote CJR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eInstallation Requirement\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003eFTA and remote CJR must be located in the same cabinet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8594px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.8594px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.8594px;\"\u003e\u003cspan\u003e1.34 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e51304362-150\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 51304362-150 is a CE-compliant, conformally coated LL Mux Input\/Output Processor used to multiplex 32 low-level analog inputs from two 16-channel Field Termination Assemblies (FTAs). It is specifically engineered for use in temperature-sensitive applications such as thermocouples and RTDs. Compatible FTAs include MU-TAMT02 and MU-TAMT03 (with built-in Cold Junction Reference) or MU-TAMT12 and MU-TAMT13 (for use with external CJR sensors). All termination and sensing components must be mounted within the same cabinet. The unit is not redundancy-capable and is built for single-processor installations where precise low-level signal conversion is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e32 Input Channel Support: Interfaces with two 16-channel FTAs for high-density analog signal acquisition.\u003c\/li\u003e\n\u003cli\u003eHigh Sampling Rate: Scans all 32 inputs at a consistent rate of 32 samples per second for responsive signal processing.\u003c\/li\u003e\n\u003cli\u003eMultiple Input Types Supported: Accepts thermocouple, RTD, and linear millivolt signals with high resolution.\u003c\/li\u003e\n\u003cli\u003eFTA Compatibility: Works with FTAs featuring either local or remote Cold Junction Reference (CJR), ensuring temperature compensation flexibility.\u003c\/li\u003e\n\u003cli\u003eCE-Compliant and Conformally Coated: Provides added reliability and protection in harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003eCompact Integration: Designed to fit seamlessly into Honeywell’s Experion or TDC system cabinets.\u003c\/li\u003e\n\u003cli\u003eNon-Redundant Design: Intended for non-redundant system architectures, simplifying deployment.\u003c\/li\u003e\n\u003cli\u003eCabinet-Based Sensor Layout: Requires all wiring and CJR sensor components to be installed within a single enclosure.\u003c\/li\u003e\n\u003cli\u003eReliable Multiplexing Architecture: Enables efficient data acquisition from a high number of low-energy analog signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 51304362-150 ensures high-density, accurate analog input processing in demanding industrial and temperature-critical applications.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105364091136,"sku":"51304362-150","price":2585.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/474351d98095465ce85e38.png?v=1785545616","url":"https:\/\/alotechparts.com\/products\/51304362-150-honeywell-low-level-analog-input-multiplexer-processor","provider":"Alo Tech Solutions","version":"1.0","type":"link"}