{"product_id":"51197564-200-honeywell-ucn-fiber-optic-extender","title":"51197564-200 | Honeywell UCN Fiber Optic Extender","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003eThe Honeywell 51197564-200 is a fiber optic signal extender designed for use with Honeywell’s Universal Control Network (UCN). Powered by 24 VDC, this device enables long-distance, high-integrity communication over fiber optics in industrial automation environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 274.906px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 26.5625px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 28.5455%; text-align: left; height: 26.5625px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 71.0909%; height: 26.5625px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.1719px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 28.5455%; text-align: left; height: 24.1719px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 71.0909%; height: 24.1719px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.9219px;\"\u003e\n\u003cth style=\"width: 28.5455%; text-align: left; height: 24.9219px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 71.0909%; height: 24.9219px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003eIndustrial Networking Devices\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.75px;\"\u003e\n\u003cth style=\"width: 28.5455%; text-align: left; height: 24.75px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 71.0909%; height: 24.75px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e51197564-200\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 28.5455%; text-align: left; height: 19.5938px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 71.0909%; height: 19.5938px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eFiber Optic Communication Extenders\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 28.5455%; text-align: left; height: 19.5938px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"width: 71.0909%; height: 19.5938px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan\u003e24 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.1875px;\"\u003e\n\u003cth style=\"width: 28.5455%; text-align: left; height: 23.1875px;\"\u003eMaximum Distance\u003c\/th\u003e\n\u003ctd style=\"width: 71.0909%; height: 23.1875px;\"\u003eUp to 2 kilometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.1875px;\"\u003e\n\u003cth style=\"width: 28.5455%; text-align: left; height: 24.1875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003ePower Consumption\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 71.0909%; height: 24.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e15 watts maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.1875px;\"\u003e\n\u003cth style=\"width: 28.5455%; text-align: left; height: 13.1875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width: 71.0909%; height: 13.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e25 cm × 10 cm × 8 cm\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 28.5455%; text-align: left; height: 26.1875px;\"\u003eApplication\u003c\/th\u003e\n\u003ctd style=\"width: 71.0909%; height: 26.1875px;\"\u003eUniversal Control Network (UCN) signal extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 28.5455%; text-align: left; height: 26.1875px;\"\u003eMounting Style\u003c\/th\u003e\n\u003ctd style=\"width: 71.0909%; height: 26.1875px;\"\u003ePanel or enclosure-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.375px;\"\u003e\n\u003cth style=\"width: 28.5455%; text-align: left; height: 22.375px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 71.0909%; height: 22.375px;\"\u003e\u003cspan\u003e2.86 kg\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e51197564-200\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThis UCN Fiber Optic Extender is built to support robust data transmission across large facilities, with a maximum communication distance of up to 2 kilometers. Operating on 24 VDC, it consumes up to 15 watts of power, making it energy-efficient for continuous use. The unit ensures reliable signal extension by minimizing noise and interference common in electrically harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLong-Distance Signal Extension: Supports fiber optic communication up to 2 km for extended UCN installations.\u003c\/li\u003e\n\u003cli\u003e24 VDC Operation: Standard low-voltage power input suitable for industrial control systems.\u003c\/li\u003e\n\u003cli\u003eEfficient Power Use: Consumes a maximum of 15 watts for continuous operation in demanding environments.\u003c\/li\u003e\n\u003cli\u003eRugged Construction: Enclosure built to withstand harsh installation conditions with a compact footprint.\u003c\/li\u003e\n\u003cli\u003eInterference-Free Transmission: Fiber optic design eliminates electrical noise and ground loop issues.\u003c\/li\u003e\n\u003cli\u003eHoneywell System Integration: Specifically designed for Universal Control Network applications in Honeywell DCS environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 51197564-200 enhances system flexibility and scalability by enabling remote control cabinet or process node connectivity across wide facility layouts.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105373397248,"sku":"51197564-200","price":5731.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/14_177ad6cf-339b-46c3-964e-e32c7936008c.png?v=1785545752","url":"https:\/\/alotechparts.com\/products\/51197564-200-honeywell-ucn-fiber-optic-extender","provider":"Alo Tech Solutions","version":"1.0","type":"link"}