{"product_id":"4100-3110-simplex-idnet-22-addressable-interface-module-250-point-capacity","title":"4100-3110 | Simplex IDNet 2+2 Addressable Interface Module 250-Point Capacity","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Simplex 4100-3110 IDNet Addressable Interface Module enables reliable communication and control between a fire alarm control panel and addressable field devices. Designed with a 250-point capacity, it supports four isolated Class A or Class B output loops for efficient signal distribution and fault tolerance.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 431.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003e4100-3110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eIDNet Addressable Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eIDNet 2+2 Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003e250 Addressable Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eOutput Loops\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eFour Short-Circuit Isolating Loops (Class A or B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eFully Isolated Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 39.2px;\"\u003e\u003cstrong\u003eAlarm Current Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 39.2px;\"\u003e50+ Devices Including 20 Device LEDs in Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eExpands Addressable Loop Capacity in Fire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 39.2px;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 39.2px;\"\u003eIDNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eSimplex 4100 Series Fire Alarm Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eUL Listed for Fire Alarm Use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003e3.00 in (H) × 4.00 in (W) × 8.00 in (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eControl Cabinet or Equipment Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003eSupplied from Main FACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 39.2px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 39.2px;\"\u003eIndoor, Controlled Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 27.2587%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.6081%; height: 19.6px;\"\u003e0.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e4100-3110\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 4100-3110 is an IDNet 2+2 Addressable Interface Module engineered for Simplex 4100 fire alarm control panels. It provides a 250-point capacity and features four Class A or Class B loops that are short-circuit isolating and electrically independent. This configuration allows secure and redundant communication paths between the control panel and addressable devices, ensuring system reliability. The module also supports alarm currents for more than 50 devices, including illumination for 20 active LEDs during alarm conditions. With its compact design and durable construction, the 4100-3110 offers dependable performance in large-scale or mission-critical fire alarm installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Capacity Addressable Interface: Supports up to 250 addressable devices, providing extensive system scalability.\u003c\/li\u003e\n\u003cli\u003eFour Isolated Output Loops: Includes four electrically isolated Class A or B output loops for enhanced reliability and fault separation.\u003c\/li\u003e\n\u003cli\u003eIntegrated Short-Circuit Isolation: Automatically isolates faults on any loop without affecting system performance.\u003c\/li\u003e\n\u003cli\u003eLED Alarm Support: Supplies sufficient alarm current for up to 20 device LEDs while maintaining signal integrity.\u003c\/li\u003e\n\u003cli\u003eElectrical Isolation Protection: Reduces risk of electrical interference and ensures consistent communication between devices.\u003c\/li\u003e\n\u003cli\u003eFlexible System Integration: Designed for seamless compatibility with Simplex 4100 fire alarm control systems.\u003c\/li\u003e\n\u003cli\u003eCompact Modular Form: Fits easily within existing control cabinets or expansion enclosures.\u003c\/li\u003e\n\u003cli\u003eUL Listed Compliance: Certified to meet fire alarm safety and reliability standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 4100-3110 delivers the reliability and precision required for advanced fire alarm networking and addressable communication control.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":49105145594112,"sku":"4100-3110","price":730.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/4100-31101.jpg?v=1785541265","url":"https:\/\/alotechparts.com\/products\/4100-3110-simplex-idnet-22-addressable-interface-module-250-point-capacity","provider":"Alo Tech Solutions","version":"1.0","type":"link"}