{"product_id":"4100-0625-simplex-4100es-local-mode-transponder-interface-card-tic","title":"4100-0625 | Simplex 4100ES Local Mode Transponder Interface Card (TIC)","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Simplex 4100-0625 Local Mode Transponder Interface Card (TIC) is a dedicated control module used in 4100ES fire alarm systems to manage transponder operation in the event of communication loss with the main control panel. In local mode, it provides autonomous alarm response for connected inputs and notification circuits.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 470.251px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003ePanel Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003e4100-0625\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eEnclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eLocal Mode Transponder Interface Card (TIC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eSimplex 4100ES Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 39.1875px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 39.1875px;\"\u003eProvides local alarm control during RUI communication loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 39.1875px;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 39.1875px;\"\u003eRemote Unit Interface (RUI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eBlock A, within MINIPLEX transponder bay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Distribution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eIntegrated with bay power management board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eLocal alarm mode (activates NACs only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eNotification Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eControls local NAC outputs in alarm mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eAuxiliary Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eDisabled during local mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003e24 VDC nominal (from transponder power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eIndication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eLocal status via panel diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eUL 864, NFPA 72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 39.1875px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 39.1875px;\"\u003eIndoor, dry location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003eApprox. 10\" × 6\" × 1.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0037%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6836%; height: 19.5938px;\"\u003e1.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e4100-0625\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 4100-0625 is part of the Simplex 4100ES system’s MINIPLEX transponder architecture. It functions as the local controller that maintains alarm response capability if RUI (Remote Unit Interface) communication with the master controller is interrupted. Installed in Block A of the transponder bay, it includes a power distribution interface and integrates with other transponder modules to maintain essential fire alarm signaling. During local operation, the card activates all connected notification appliance circuits (NACs) when an alarm input is triggered but disables auxiliary relay and control outputs for safety. This fail-safe feature ensures continued local alarm signaling and reliability in distributed fire alarm networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocal Mode Operation: Provides autonomous alarm activation if communication with the master controller is lost.\u003c\/li\u003e\n\u003cli\u003eRUI Communication: Interfaces with 4100ES host panel via Simplex Remote Unit Interface network.\u003c\/li\u003e\n\u003cli\u003eFail-Safe Design: Ensures alarm NACs remain active in isolation scenarios while disabling non-critical outputs.\u003c\/li\u003e\n\u003cli\u003eTransponder Integration: Installed in 4100ES MINIPLEX transponder cabinets for distributed system control.\u003c\/li\u003e\n\u003cli\u003ePower Distribution Interface: Includes bay power management and interconnection for other modules.\u003c\/li\u003e\n\u003cli\u003eAlarm Circuit Control: Activates all local alarm notification appliances in the event of an alarm signal.\u003c\/li\u003e\n\u003cli\u003eModular Architecture: Mounts in Block A position within the transponder bay chassis.\u003c\/li\u003e\n\u003cli\u003eStatus Communication: Translates internal transponder communication into standard host system format.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Certified for fire alarm system control applications under UL 864.\u003c\/li\u003e\n\u003cli\u003eReliability Assurance: Designed to maintain essential system functionality during communication failures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 4100-0625 ensures that 4100ES fire alarm systems retain basic alarm functions even under network failure conditions, enhancing safety and operational reliability.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":49105157390592,"sku":"4100-0625","price":498.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_cff5a226-3746-43e1-bf19-67252e3ea19d.webp?v=1785541539","url":"https:\/\/alotechparts.com\/products\/4100-0625-simplex-4100es-local-mode-transponder-interface-card-tic","provider":"Alo Tech Solutions","version":"1.0","type":"link"}