{"product_id":"4099-9003-simplex-addressable-double-action-manual-pull-station","title":"4099-9003 | Simplex Addressable Double-Action Manual Pull Station","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Simplex 4099-9003 is an addressable double-action manual pull station with integral IAM module for MAPNET II or IDNet communication. Designed for reliable fire alarm activation, it features a red housing, visible status LED, and compatibility with multiple Simplex control panels.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 271.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 16.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 16.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 16.6px;\"\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003e4099-9003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003eManual Pull Station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003eAddressable, double-action\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003eDual-action, push lever with optional break-rod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003eSimplex 4009, 4010, 4100U, 4120, and compatible series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003eMAPNET II or IDNet (power and data on single pair)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003eVisible LED (flashes during comms, steady when activated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eHousing Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003eRugged manual station housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003e5 × 5 × 5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.024%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.5616%; height: 19.6px;\"\u003e4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e4099-9003\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 4099-9003 is a dual-action addressable pull station from Simplex, built with integrated IAM communication for seamless connection to MAPNET II or IDNet fire alarm systems. Its compact communication module continuously monitors station status and reports any change directly to the control panel. The station includes a flashing LED for communication confirmation and a steady LED when activated, ensuring clear visibility for operators. With a durable red housing, protruding alarm lever, and optional break-rod, it provides both reliability and compliance in commercial, institutional, and industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAddressable Integration: Features an integral IAM module for direct MAPNET II or IDNet communication, providing constant supervision of pull station status.\u003c\/li\u003e\n\u003cli\u003eDual-Action Design: Requires a two-step activation (lift cover\/push lever), significantly reducing accidental or false alarms.\u003c\/li\u003e\n\u003cli\u003eVisual Status Indication: Equipped with an LED that flashes during panel communication and remains steadily lit when the pull station is activated.\u003c\/li\u003e\n\u003cli\u003eProtruding Alarm Lever: Provides immediate visual and tactile confirmation of alarm activation, helping responders quickly identify the triggered station.\u003c\/li\u003e\n\u003cli\u003eOptional Break-Rod: Includes a break-rod accessory for added tamper resistance, commonly required in high-traffic or public areas.\u003c\/li\u003e\n\u003cli\u003eWide System Compatibility: Works seamlessly with Simplex 4009, 4010, 4100U, 4120, and other compatible addressable fire alarm panels.\u003c\/li\u003e\n\u003cli\u003eSingle-Pair Wiring: Power and communication are delivered over a single wire pair, simplifying installation and reducing cabling requirements.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Built with a rugged red enclosure for long-term reliability in demanding environments such as schools, hospitals, and industrial facilities.\u003c\/li\u003e\n\u003cli\u003eClear User Feedback: Station design includes tactile confirmation upon lever activation and LED visibility to ensure users know the alarm has been triggered.\u003c\/li\u003e\n\u003cli\u003eCompliance Assurance: Designed to meet fire alarm system codes and standards for addressable manual activation devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 4099-9003 delivers the reliability and precision required for manual fire alarm activation in addressable Simplex systems.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":49105181278464,"sku":"4099-9003","price":330.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Simplex-4099-9003-Addressable-Manual-Pull-Station-Red_b46d2368-ed65-4046-b3c5-91cf53261a85.71cc822e694503f17235520e271bc5be.jpg?v=1785542019","url":"https:\/\/alotechparts.com\/products\/4099-9003-simplex-addressable-double-action-manual-pull-station","provider":"Alo Tech Solutions","version":"1.0","type":"link"}