{"product_id":"3va4112-6ed34-0aa0-siemens-3va4-125a-3-pole-480v-thermal-magnetic-circuit-breaker","title":"3VA4112-6ED34-0AA0 | Siemens 3VA4 125A 3-Pole 480V Thermal-Magnetic Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens® 3VA4112-6ED34-0AA0 is a 3-pole, 125A thermal-magnetic molded case circuit breaker (MCCB) from the 3VA4 SENTRON series, designed for dependable line protection in industrial and commercial electrical systems. Operating at up to 600Y\/347V AC with a breaking capacity of 65 kA at 480V, it ensures precise overload and short-circuit protection through its TM210 trip unit. Compact, durable, and UL489 compliant, this breaker is ideal for applications requiring high interrupting capacity and continuous performance reliability.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 568.22px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eCircuit Protection Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e3VA4112-6ED34-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eSENTRON 3VA4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e3VA41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eRated Voltage (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e600Y\/347V, 480V, 690V (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eTrip Unit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eTM210 (Thermal-Magnetic, LI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e65 kA @ 480V, 25 kA @ 600Y\/347V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 40%; height: 39.1875px;\"\u003e\u003cstrong\u003eProtection Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 39.1875px;\"\u003eLong-time overload (Ir), instantaneous short-circuit (Ii)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eOverload Protection Setting (Ir)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e125 A (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 40%; height: 39.1875px;\"\u003e\u003cstrong\u003eShort-Circuit Protection Setting (Ii)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 39.1875px;\"\u003e10 × In (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eTerminal Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eLoad side lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eDesign \/ Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eSystem and line protection breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eFixed \/ Panelboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eEndurance (Mechanical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e15,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eEndurance (Electrical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e8,000 @ 480V, 4,000 @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Loss (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e29.1 W total (9.7 W per pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompliance \/ Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eUL489, HACR Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eGround Fault Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003eGermany \/ Mexico (depending on lot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40%; height: 19.5938px;\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.3234%; height: 19.5938px;\"\u003e0.743 kg (1.64 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 3VA4112-6ED34-0AA0\u003c\/h4\u003e\n\u003cp\u003eThe 3VA4112-6ED34-0AA0 is part of the Siemens 3VA4 UL-rated molded case circuit breaker family, engineered for consistent protection of distribution circuits and connected equipment. It features a 3VA41 frame, a Class H high-breaking capacity, and a TM210 LI trip unit offering fixed long-time and instantaneous protection characteristics. With a rated operational voltage of 690V AC and mechanical endurance up to 15,000 operations, this circuit breaker ensures long-term performance even in demanding conditions. The load-side lug terminal design and compact form factor enable straightforward installation in control panels or distribution boards. Its robust construction and compliance with UL489 and HACR standards make it suitable for HVAC, motor protection, and general industrial power distribution applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal-Magnetic Trip Unit (TM210): Provides long-time (Ir) and instantaneous (Ii) overcurrent protection.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: 65kA @ 480V and 25kA @ 600Y\/347V for reliable fault protection.\u003c\/li\u003e\n\u003cli\u003eVersatile Application Use: UL489 HACR type suitable for heating, air conditioning, and refrigeration systems.\u003c\/li\u003e\n\u003cli\u003eCompact 3VA41 Frame: Optimized for high performance with minimal panel space requirements.\u003c\/li\u003e\n\u003cli\u003eWide Voltage Range: Rated for up to 690V AC operation with a continuous current of 125A.\u003c\/li\u003e\n\u003cli\u003eDurable Performance: 15,000 mechanical and up to 8,000 electrical operating cycles.\u003c\/li\u003e\n\u003cli\u003eFixed Line Protection Settings: Simplifies commissioning and ensures consistent system coordination.\u003c\/li\u003e\n\u003cli\u003eUL Listed and SENTRON Quality: Meets international standards for industrial circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 3VA4112-6ED34-0AA0 delivers the precision, durability, and safety demanded in critical power distribution and protection systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105086349568,"sku":"3VA4112-6ED34-0AA0","price":1174.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/3VA4112-6ED34-0AA0.jpg?v=1785539829","url":"https:\/\/alotechparts.com\/products\/3va4112-6ed34-0aa0-siemens-3va4-125a-3-pole-480v-thermal-magnetic-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}