{"product_id":"3rk1904-2ab02-siemens-as-interface-addressing-and-diagnosis-device","title":"3RK1904-2AB02 | Siemens AS-Interface Addressing and Diagnosis Device","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003eThe Siemens 3RK1904-2AB02 is an AS-Interface (AS-i) Addressing and Diagnosis Device designed for easy configuration, testing, and maintenance of AS-i slave modules in industrial automation networks. Featuring v3.0 functionality, this device streamlines setup and diagnostics of active AS-i modules, intelligent sensors, and actuators.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 395.917px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 28.4306px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 25.6421%; text-align: left; height: 28.4306px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 74.0369%; height: 28.4306px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 29.7778px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 25.6421%; text-align: left; height: 29.7778px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 74.0369%; height: 29.7778px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eSiemens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.5556px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 21.5556px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 21.5556px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\u003cspan\u003ePLCs\/Machine Control\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.2778px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 24.2778px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 24.2778px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e3RK1904-2AB02\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.375px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 23.375px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 23.375px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003ePLC Programming Terminal\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.1806px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 22.1806px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eAS-i Specification\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 22.1806px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eV3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 19.5972px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eFunctionality\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 19.5972px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eAddress setting, input\/output test, diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 39.1806px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 39.1806px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eM12 connection socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.1806px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 20.1806px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eAddressing Cable\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 20.1806px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e1.5 m (M12 connector\/hollow plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.1806px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 30.1806px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003ePower Source\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 30.1806px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e4 x 1.5 V LR6 batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 39.1944px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eApplication Module Addressing\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 39.1944px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eVia 3RK1901-1MA00 adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 39.1944px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003e\u003cspan\u003ePackaging Dimension\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 39.1944px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan\u003e216,00 x 205,00 x 76,00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 39.1944px;\"\u003e\u003cspan\u003ePackage size unit of measure\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 39.1944px;\"\u003e\u003cspan\u003eMM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 19.5972px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 19.5972px;\"\u003e\u003cspan\u003e0,565 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e3RK1904-2AB02\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 3RK1904-2AB02 is engineered to support the AS-i specification v3.0, ensuring compatibility with the latest generation of AS-i modules. It is equipped with an M12 connection socket and includes a 1.5-meter addressing cable with an M12 connector and hollow plug, simplifying direct connection to modules. This device allows for the quick setting of slave addresses, input\/output testing, and other essential functions needed for commissioning and troubleshooting AS-i networks. It operates on four standard 1.5V LR6 batteries, making it portable and easy to use in various installation and maintenance scenarios. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAS-Interface V3.0 Compliance: Fully supports AS-i slave modules and networks that conform to the latest AS-i specification, ensuring compatibility with modern automation systems.\u003c\/li\u003e\n\u003cli\u003eAddressing and Diagnostics: Facilitates setting addresses for AS-i modules and includes functions for input\/output testing and other diagnostic tasks, streamlining system commissioning and maintenance.\u003c\/li\u003e\n\u003cli\u003eM12 Connection Socket: Provides a reliable and standardized connection interface for quick and secure module access in the field.\u003c\/li\u003e\n\u003cli\u003eIncluded Addressing Cable: Comes with a 1.5-meter cable equipped with an M12 connector and hollow plug, enabling flexible and convenient connectivity to AS-i modules.\u003c\/li\u003e\n\u003cli\u003eBattery Powered: Operates using four standard 1.5V LR6 batteries, ensuring portability and easy deployment without requiring external power sources.\u003c\/li\u003e\n\u003cli\u003eDirect Application Module Addressing: Supports addressing of application modules via the 3RK1901-1MA00 adapter, increasing flexibility and utility in different system configurations.\u003c\/li\u003e\n\u003cli\u003eCompact and Durable Design: Built to withstand the rigors of industrial environments while maintaining lightweight and ergonomic usability for field technicians.\u003c\/li\u003e\n\u003cli\u003eUser-Friendly Interface: Intuitive operation simplifies configuration, troubleshooting, and maintenance of AS-i networks, reducing downtime and training requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 3RK1904-2AB02 is an indispensable tool for engineers and technicians responsible for setting up, maintaining, and troubleshooting AS-Interface networks, offering reliable performance and ease of use.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105409442048,"sku":"3RK1904-2AB02","price":1605.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/shopping_24_bffb02d2-cf48-4789-976e-c4fdb35da8b1.jpg?v=1785546445","url":"https:\/\/alotechparts.com\/products\/3rk1904-2ab02-siemens-as-interface-addressing-and-diagnosis-device","provider":"Alo Tech Solutions","version":"1.0","type":"link"}