{"product_id":"30546-25-gamewell-fci-flexalert-fire-alarm-control-board","title":"30546-25 | Gamewell-FCI FlexAlert Fire Alarm Control Board","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Gamewell-FCI 30546-25 FlexAlert Fire Alarm Control Board is a control circuit assembly designed for use within the FlexAlert fire alarm system platform. It provides supervision, signaling, and control of connected detection and notification circuits to ensure proper system operation.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eGamewell-FCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003e30546-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eFire Alarm Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eFlexAlert fire alarm system main board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eCircuit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eSupervised initiating and notification appliance circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eInput Power Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eExternal regulated power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003ePanel-mounted bus and field wiring terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eOnboard LEDs for alarm, trouble, and power status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eDetects open, short, and ground faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eMicroprocessor-based control logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003ePanel-mounted PCB assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eFiberglass PCB with protective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eUL Listed; NFPA 72 compliant (legacy systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003eApprox. 10\" L × 6\" W × 1.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.1227%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.658%;\"\u003e1.1 lb (0.50 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 30546-25\u003c\/h4\u003e\n\u003cp\u003eThe 30546-25 is a main control board developed by Gamewell-FCI for legacy FlexAlert conventional fire alarm systems. It manages multiple initiating and notification appliance circuits, providing precise monitoring of alarms, troubles, and supervisory conditions. The board’s integrated microprocessor ensures accurate signal processing, while onboard terminals allow direct wiring to field devices and power supplies. Designed for use in both commercial and industrial applications, the 30546-25 offers durable, reliable performance in fire detection and signaling control. Though discontinued by the manufacturer, it remains a vital replacement component for maintaining or repairing existing FlexAlert systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCentral Control Function: Operates as the main logic and communication board for FlexAlert systems.\u003c\/li\u003e\n\u003cli\u003eMulti-Circuit Management: Supports multiple supervised initiating and notification circuits.\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-Based Design: Ensures reliable system monitoring and control logic.\u003c\/li\u003e\n\u003cli\u003eTrouble and Alarm Supervision: Detects open, short, and ground faults for enhanced safety.\u003c\/li\u003e\n\u003cli\u003eDirect Field Wiring: Terminal connections allow straightforward integration of devices and power.\u003c\/li\u003e\n\u003cli\u003eNotifier-Compatible Layout: Designed to operate within legacy FlexAlert control panel enclosures.\u003c\/li\u003e\n\u003cli\u003eLED Indicators: Provides visual feedback for alarm, trouble, and normal conditions.\u003c\/li\u003e\n\u003cli\u003eLegacy System Support: Essential for maintaining discontinued Gamewell-FCI FlexAlert systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 30546-25 delivers the reliability and precision required for system control and supervision in legacy FlexAlert fire alarm applications.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":49105150443776,"sku":"30546-25","price":2343.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_36c4e1e1-3c57-4b4c-8ea1-b5d19cfd2f19.webp?v=1785541369","url":"https:\/\/alotechparts.com\/products\/30546-25-gamewell-fci-flexalert-fire-alarm-control-board","provider":"Alo Tech Solutions","version":"1.0","type":"link"}