{"product_id":"2190-9172-simplex-individually-addressable-module-iam-mapnet-ii-fire-alarm-interface","title":"2190-9172 | Simplex Individually Addressable Module (IAM) MAPNET II Fire Alarm Interface","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Simplex 2190-9172 Individually Addressable Module (IAM) is designed for MAPNET II fire alarm systems to provide point-specific device communication and supervision. It enables conventional devices to interface directly with the control panel, supporting 40 VDC operation at low current draw for efficient monitoring.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 372.4px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003e2190-9172\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eIndividually Addressable Module (IAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eMAPNET II Fire Alarm System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eAddressable Device Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003e40 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003e2.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eCommunication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eMAPNET II Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eInline or Enclosure Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eDevice Addressing and Supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eTwo-Wire Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eSimplex MAPNET II Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eDurable Encapsulated Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003eIndoor, Controlled Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003e2.00 in (H) × 2.00 in (W) × 5.00 in (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 21.9609%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77.9059%; height: 19.6px;\"\u003e0.25 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e2190-9172\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe 2190-9172 is an Individually Addressable Module (IAM) built for Simplex MAPNET II systems to convert conventional input points into individually addressable communication nodes. It provides supervised input monitoring for connected devices, allowing each point to be independently identified by the control panel. The module operates at 40 VDC with only 2.2 mA of current, ensuring energy-efficient system performance. Compact and reliable, the 2190-9172 enhances system flexibility by allowing simple expansion of existing networks without major rewiring or redesign.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMAPNET II Protocol Compatibility: Designed for seamless communication within MAPNET II addressable fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eIndividually Addressable Monitoring: Converts standard input points into uniquely supervised addressable devices for precise identification.\u003c\/li\u003e\n\u003cli\u003eLow Power Consumption: Operates efficiently at 40 VDC with a minimal current draw of 2.2 mA.\u003c\/li\u003e\n\u003cli\u003eCompact and Lightweight Design: Measures only 2 × 2 × 5 inches and weighs 0.25 lbs for easy integration in tight spaces.\u003c\/li\u003e\n\u003cli\u003eFlexible Mounting Options: Can be installed inline or within electrical enclosures for adaptable configurations.\u003c\/li\u003e\n\u003cli\u003eReliable Device Supervision: Continuously monitors connected field devices for faults or wiring issues.\u003c\/li\u003e\n\u003cli\u003eDurable Encapsulation: Protects electronic components from dust and vibration for long-term stability.\u003c\/li\u003e\n\u003cli\u003eSystem Expansion Support: Simplifies addition of new monitored points to existing MAPNET II networks without disruption.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 2190-9172 delivers the reliability and precision required for accurate device supervision and addressable communication within Simplex MAPNET II fire alarm systems.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":49105145299200,"sku":"2190-9172","price":698.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/4d9d14252f84413ba771b12e997f0beb.jpg?v=1785541255","url":"https:\/\/alotechparts.com\/products\/2190-9172-simplex-individually-addressable-module-iam-mapnet-ii-fire-alarm-interface","provider":"Alo Tech Solutions","version":"1.0","type":"link"}