{"product_id":"1492-rcda2a25-allen-bradley-residual-current-device","title":"1492-RCDA2A25 | Allen-Bradley Residual Current Device","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Allen-Bradley 1492-RCDA2A25 is a 2-pole residual current device (RCD) rated at 25 A with a 30 mA sensitivity, designed to detect and interrupt leakage currents to ground.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eAllen-Bradley \u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\u003cspan\u003eControls \u0026amp; Indicators\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e1492-RCDA2A25\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eSubcatecory\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem]  md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003cdiv class=\"flex gap-[1.75rem]  md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem]  md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\u003cspan\u003eCurrent Limiter\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eActuator\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003eToggle Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan\u003eFor Industrial use\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eInterrupt Rating\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003e1, 10 kAIC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eNumber of Poles\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003e2 Pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003eCCC,CE,CUL,UL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003eStandard Configuration, Ground Fault\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003e25 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eBlade Dimensions\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003e1.37 in W x 2.63 in D x 3.46 in H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003eDIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eSplit Crucible\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003eS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eTrip Range\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003e30 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003e230\/400 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 19.5938px;\"\u003e\n\u003cdiv class=\"specLabel\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003e0.44 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 1492-RCDA2A25\u003c\/h4\u003e\n\u003cp data-start=\"66\" data-end=\"415\" class=\"\"\u003eThe\u003cstrong\u003e \u003c\/strong\u003eAllen-Bradley 1492-RCDA2A25 is a compact, industrial-grade residual current device (RCD) designed as part of the Allen-Bradley Bulletin 1492-RCDA Series. It provides reliable earth leakage protection for electrical systems, enhancing personnel safety and preventing equipment damage in a wide range of industrial and commercial applications.\u003c\/p\u003e\n\u003ch4 data-start=\"422\" data-end=\"1439\"\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"422\" data-end=\"1439\"\u003eType: Residual Current Device (Type A) with 2-pole configuration\u003cbr data-start=\"510\" data-end=\"513\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"422\" data-end=\"1439\"\u003eRated Current: 25 A\u003cbr data-start=\"536\" data-end=\"539\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"422\" data-end=\"1439\"\u003eTrip Sensitivity: 30 mA, for effective detection of leakage currents\u003cbr data-start=\"611\" data-end=\"614\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"422\" data-end=\"1439\"\u003eVoltage Rating: 110\/220 V AC\u003cbr data-start=\"646\" data-end=\"649\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"422\" data-end=\"1439\"\u003eSupported Applications: Ideal for protecting circuits in industrial machinery, control panels, and commercial electrical installations, reducing the risk of electric shock and electrical fires\u003cbr data-start=\"845\" data-end=\"848\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"422\" data-end=\"1439\"\u003eFunctionality: Rapidly detects and disconnects circuits experiencing earth leakage, offering enhanced safety and compliance with international standards\u003cbr data-start=\"1004\" data-end=\"1007\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"422\" data-end=\"1439\"\u003eForm Factor: Compact design with screw terminals and DIN rail mounting for easy integration into existing systems\u003cbr data-start=\"1124\" data-end=\"1127\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"422\" data-end=\"1439\"\u003eInstallation: Simple wiring and secure mounting, compatible with miniature circuit breakers for combined circuit and leakage current protection\u003cbr data-start=\"1274\" data-end=\"1277\"\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"422\" data-end=\"1439\"\u003eConstruction: Robust build conforming to IEC\/EN 61008 and UL 1053 standards, ensuring durability, safety, and consistent performance in demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1446\" data-end=\"1659\" class=\"\"\u003eThe 1492-RCDA2A25 is ideal for organizations seeking reliable, compact, and efficient residual current protection for enhancing safety and safeguarding electrical systems in industrial and commercial settings.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":49105444503808,"sku":"1492-RCDA2A25","price":458.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/1492-RCDA2_1000x1000_6383ecf5-a6f3-4203-9051-d567131f48b6.jpg?v=1785547240","url":"https:\/\/alotechparts.com\/products\/1492-rcda2a25-allen-bradley-residual-current-device","provider":"Alo Tech Solutions","version":"1.0","type":"link"}