{"product_id":"140u-h6c2-c15-allen-bradley-molded-case-circuit-breaker-125a","title":"140U-H6C2-C15 | Allen-Bradley Molded Case Circuit Breaker 125A","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003eThe Allen-Bradley 140U-H6C2-C15 is a molded case circuit breaker designed for high-performance protection of industrial electrical systems. Featuring a robust H-Frame construction, this 2-pole breaker delivers reliable overcurrent and short-circuit protection in a compact design.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 333.458px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 28.2917px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 25.6421%; text-align: left; height: 28.2917px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 74.0369%; height: 28.2917px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.5278px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 25.6421%; text-align: left; height: 27.5278px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 74.0369%; height: 27.5278px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eAllen-Bradley \u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 19.5972px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 19.5972px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\u003cspan\u003eCircuit Breaker\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 19.5972px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 19.5972px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e140U-H6C2-C15\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 19.5972px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 19.5972px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eMolded Case Circuit Breaker\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 25.6421%; height: 19.5972px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 19.5972px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e140U Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.9306px;\"\u003e\n\u003cth style=\"width: 25.6421%; height: 20.9306px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eFrame Type\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 20.9306px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eH-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 25.6421%; height: 39.1944px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eInterrupting Capacity\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 39.1944px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e60 to 69 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 25.6421%; height: 19.5972px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eRated Current\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 19.5972px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.5556px;\"\u003e\n\u003cth style=\"width: 25.6421%; height: 21.5556px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 21.5556px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 19.5972px;\"\u003eTrip Unit Type\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 19.5972px;\"\u003eFixed Thermal \/ Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 39.1806px;\"\u003eVoltage Class\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 39.1806px;\"\u003eAC (standard industrial voltages)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 25.6421%; text-align: left; height: 19.5972px;\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 19.5972px;\"\u003ePanel Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 25.6421%; height: 19.5972px; text-align: left;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 74.0369%; height: 19.5972px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan\u003e3.00 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e140U-H6C2-C15\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003ePart of the Allen-Bradley 140U Series, the 140U-H6C2-C15 molded case circuit breaker combines a fixed thermal and fixed magnetic trip unit to safeguard electrical circuits against overloads and short circuits. It is rated for a maximum interrupting capacity of 60 to 69 kA, ensuring dependable performance in even the most demanding industrial applications. This model features a 2-pole configuration and is factory set for a rated current of 15 A, offering straightforward protection for various branch circuits. Its H-Frame design supports easy panel mounting, and its molded case construction ensures durability and consistent performance over its service life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eH-Frame Construction: Robust design ensures mechanical strength and reliable performance in demanding industrial environments, supporting consistent operation and long service life.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Offers a short-circuit interrupting rating of 60 to 69 kA, providing exceptional protection against high-fault currents in critical applications.\u003c\/li\u003e\n\u003cli\u003eFixed Thermal and Fixed Magnetic Trip Units: Ensures reliable overcurrent and short-circuit protection without the need for field adjustments, simplifying installation and maintenance.\u003c\/li\u003e\n\u003cli\u003e2-Pole Configuration: Provides simultaneous switching and protection of both lines, ensuring system safety and compliance with industrial standards.\u003c\/li\u003e\n\u003cli\u003eRated Current: Factory-set at 15 A, ideal for branch circuit protection and industrial load applications requiring a consistent protection level.\u003c\/li\u003e\n\u003cli\u003eMolded Case Design: Offers insulation and protection for the internal components, enhancing durability and safety while simplifying installation in electrical panels.\u003c\/li\u003e\n\u003cli\u003eWide Range of Applications: Suitable for use in industrial facilities, commercial buildings, and control panels requiring robust circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 140U-H6C2-C15 is a dependable solution for safeguarding industrial electrical systems, combining high interrupting capacity and durable construction in a compact design.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":49105407279360,"sku":"140U-H6C2-C15","price":917.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/iqelectro_photo2_1_26d7c60e-310d-4109-ae69-b24db1781650.png?v=1785546379","url":"https:\/\/alotechparts.com\/products\/140u-h6c2-c15-allen-bradley-molded-case-circuit-breaker-125a","provider":"Alo Tech Solutions","version":"1.0","type":"link"}