{"product_id":"140m-i8p-b30-allen-bradley-circuit-breaker","title":"140M-I8P-B30 | Allen-Bradley Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe 140M-I8P-B30 is an Allen-Bradley motor protection circuit breaker rated for 30A. It features adjustable thermal and fixed magnetic trip settings for reliable motor overload and short-circuit protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 353.516px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 23.875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 23.875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 23.875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 23.875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eAllen-Bradley\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 23.875px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 23.875px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\u003cspan\u003eCircuit Breaker\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 23.875px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 23.875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e140M-I8P-B30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.3594px;\"\u003e\n\u003cth style=\"width: 25.6364%; text-align: left; height: 25.3594px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eSubcatecory\u003c\/th\u003e\n\u003ctd style=\"width: 74%; height: 25.3594px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem]  md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003cdiv class=\"flex gap-[1.75rem]  md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem]  md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\u003cspan\u003eMolded Case Circuit Breaker\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 25.6364%; height: 23.875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74%; height: 23.875px;\"\u003e\u003cspan\u003e3 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.6364%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003eUL,KC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 25.6364%; height: 23.875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 74%; height: 23.875px;\"\u003e\u003cspan\u003eMotor Circuit Protector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 25.6364%; height: 23.875px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74%; height: 23.875px;\"\u003e\u003cspan\u003e600 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.875px;\"\u003e\n\u003ctd style=\"width: 25.6364%; height: 23.875px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74%; height: 23.875px;\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.6364%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrame Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003e3 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.6364%; height: 19.5938px;\"\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74%; height: 19.5938px;\"\u003e\u003cspan\u003eBolt-in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.6364%;\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74%;\"\u003e\u003cspan\u003e3.00 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 140M-I8P-B30\u003c\/h4\u003e\n\u003cp data-start=\"84\" data-end=\"260\" class=\"\"\u003eThe\u003cstrong\u003e \u003c\/strong\u003e140M-I8P-B30 is a motor protection circuit breaker from Allen-Bradley’s 140M series, designed to provide comprehensive protection for motors in industrial applications.\u003c\/p\u003e\n\u003ch4 data-start=\"262\" data-end=\"279\"\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"281\" data-end=\"323\"\u003eType: Motor Protection Circuit Breaker\u003c\/li\u003e\n\u003cli data-start=\"325\" data-end=\"341\"\u003eSeries: 140M\u003c\/li\u003e\n\u003cli data-start=\"343\" data-end=\"373\"\u003eCurrent Rating: 30 Amperes\u003c\/li\u003e\n\u003cli data-start=\"375\" data-end=\"402\"\u003eTrip Characteristics: Thermal: Adjustable for overload protection; Magnetic: Fixed for short-circuit protection\u003c\/li\u003e\n\u003cli data-start=\"507\" data-end=\"575\"\u003ePhase Compatibility: Designed for 3-phase motor applications\u003c\/li\u003e\n\u003cli data-start=\"577\" data-end=\"669\"\u003eInterrupting Capacity: High fault-breaking capacity (refer to datasheet for exact value)\u003c\/li\u003e\n\u003cli data-start=\"671\" data-end=\"737\"\u003eMounting: DIN rail mountable for quick and secure installation\u003c\/li\u003e\n\u003cli data-start=\"739\" data-end=\"786\"\u003eControl: Manual ON\/OFF switching capability\u003c\/li\u003e\n\u003cli data-start=\"788\" data-end=\"830\"\u003eConstruction: Rugged industrial design\u003c\/li\u003e\n\u003cli data-start=\"832\" data-end=\"863\"\u003eCertifications: UL, CSA, CE\u003c\/li\u003e\n\u003cli data-start=\"865\" data-end=\"1040\"\u003eApplications: Ideal for motor control panels, machinery, conveyors, pumps, and industrial automation systems requiring reliable motor overload and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1042\" data-end=\"1225\" class=\"\"\u003eThe 140M-I8P-B30 combines compact design, adjustable protection settings, and robust performance, making it a practical solution for safeguarding motors in demanding environments.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":49105427857664,"sku":"140M-I8P-B30","price":733.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ad9d195f81554577ae9f67da41625f67.jpg?v=1785546811","url":"https:\/\/alotechparts.com\/products\/140m-i8p-b30-allen-bradley-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}