{"product_id":"1100-0503-gamewell-fci-led-driver-module-for-annunciator-and-display-systems","title":"1100-0503 | Gamewell-FCI LED Driver Module for Annunciator and Display Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Gamewell-FCI 1100-0503 LED Driver Module is a control interface board designed to manage and power LED indicators in Gamewell-FCI fire alarm annunciator and display systems. It provides reliable activation and supervision of multiple LED outputs to visually indicate system alarms, troubles, and status conditions.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eGamewell-FCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003e1100-0503\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eLED Driver Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eControls and powers LED indicators for system annunciation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eMultiple supervised LED channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eInput Signal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eLogic control from main panel or interface board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eCurrent-limited LED drive outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eOpen and short circuit fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003ePanel or enclosure mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eHardwired control signal input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eBoard Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eFiberglass PCB with conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eGamewell-FCI E3, FlexAlarm, and legacy annunciator systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003eApprox. 6\" L × 4\" W × 1.5\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35.636%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.1447%;\"\u003e0.5 lb (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 1100-0503\u003c\/h4\u003e\n\u003cp\u003eThe 1100-0503 is an LED driver circuit module developed by Gamewell-FCI for integration into fire alarm control panels, graphic annunciators, and custom display assemblies. It receives control signals from the main panel or network controller and distributes power to corresponding LED indicators for event status visualization. Each output channel is supervised to ensure operational integrity and fault detection. Engineered for compatibility with Gamewell-FCI E3 Series and FlexAlarm systems, the 1100-0503 features a compact PCB design for efficient installation in annunciator enclosures or control cabinets. This module provides dependable performance in both new and existing fire alarm configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-Channel LED Control: Drives multiple LED indicators for alarms, troubles, and supervisory signals.\u003c\/li\u003e\n\u003cli\u003eSupervised Outputs: Monitors LED circuits for open or short faults to ensure reliable operation.\u003c\/li\u003e\n\u003cli\u003ePanel Integration: Designed for use with Gamewell-FCI E3 and FlexAlarm systems.\u003c\/li\u003e\n\u003cli\u003eCompact PCB Design: Fits easily within annunciator housings or control enclosures.\u003c\/li\u003e\n\u003cli\u003eStable Power Regulation: Provides consistent voltage output for LED operation.\u003c\/li\u003e\n\u003cli\u003ePlug-In Connectivity: Terminal-style connections simplify installation and service.\u003c\/li\u003e\n\u003cli\u003eVisual Status Indication: Enables clear and immediate system condition recognition.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Compliant: Meets standards for annunciator circuit design in life-safety systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 1100-0503 delivers the reliability and precision required for visual annunciation and LED control in Gamewell-FCI fire alarm systems.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":49105150181632,"sku":"1100-0503","price":1137.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/313986_538x514_ceb00849-f4a5-4ebe-a2e3-4466f49a5f11.png?v=1785541361","url":"https:\/\/alotechparts.com\/products\/1100-0503-gamewell-fci-led-driver-module-for-annunciator-and-display-systems","provider":"Alo Tech Solutions","version":"1.0","type":"link"}