{"product_id":"030-8-0010-k30-fr-fast-response-10000-ppm-co2-sensor","title":"030-8-0010 K30 FR Fast Response 10,000 ppm CO2 Sensor","description":"\u003cp\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eK30 FR Fast Response 10,000 ppm CO2 Sensor 030-8-0010\u003c\/strong\u003e\u003c\/span\u003e \u003cem\u003e(formerly known as SE-0117)\u003c\/em\u003e is optimized for fast response time.\u003c\/p\u003e\n\u003cp\u003eThe sample cell is well protected by a particle filter and is designed for fast diffusion without any need for external pump. In addition, there is a tube inlet to be able to feed on-line test gas through the sensor.\u003c\/p\u003e\n\u003cp\u003eThe module is designed for high volume production with full traceability by sensor serial number on all manufacturing processes and key components. Every sensor is individually calibrated and is provided with UART digital interface.\u003c\/p\u003e\n\u003cp\u003eThe K30 FR is designed for simple integration into products that requires a fast update rate of CO2 measurement. The sensor can be used in a wide range of applications where fast changes need to be detected, such as gas leakage in the food and pharmaceutical packaging industry. Other uses are human occupancy detection and leakage detection in industry environments.is a low-cost sensor solution for OEMs who want to integrate CO2 sensors into applications like high speed bottling head-space testing.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for incredibly fast response (2 seconds!)\u003c\/li\u003e\n\u003cli\u003eBuilt-in tube inlet with fast diffusion with or without pump\u003c\/li\u003e\n\u003cli\u003eFlexible analog and digital outputs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompliant with ANSI\/ASHRAE, WELL, and RESET grad B standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 FR 10,000 ppm Sensor\u003c\/strong\u003e (030-8-0010) - For integration into high-volume OEM products.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eK30 CO2 Sensor Development Kit\u003c\/strong\u003e (CM-0126) - Easy to use, simply plug the sensor module into your PC via USB. Use our free \u003ca title=\"Gaslab Software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide in real time or for data logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order sensors on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first-time users purchase either the CM-0126 or CM-200 Development Kit for fastest and easiest results\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement:\u003c\/strong\u003e Non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 - 10,000 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement:\u003c\/strong\u003e 2Hz (once every 0.5 seconds)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 2 seconds @ .5 l\/min tube gas flow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Outputs:\u003c\/strong\u003e 2 digital and 2 analog (scalable Analog voltage outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Range:\u003c\/strong\u003e 0-10,000 ppm (custom configuration required)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e UART or I2C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepeatability:\u003c\/strong\u003e ± 20 ppm ± 1 % of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± 30 ppm ± 3 % of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval:\u003c\/strong\u003e no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x W x H): \u003c\/strong\u003e51 x 57 x 14mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e \u0026lt; 1 min. (@ full specs \u0026lt; 15 min)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConformance with the standards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmission: EN61000-6-3:2001\u003c\/li\u003e\n\u003cli\u003eImmunity: EN61000-6-2:2001\u003c\/li\u003e\n\u003cli\u003eRoHS directive 2002\/95\/EG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 51 × 57 × 14 mm (L x W x H)\u003c\/li\u003e\n\u003cli\u003ePower Input: 5-14 VDC, stabilized to within 10% (external protection circuits required)\u003c\/li\u003e\n\u003cli\u003eMax Current: 300 mA\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 70 mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003ca title=\"Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cdiv class=\"manuals\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Senseair-K30-FR-CO2Meter.pdf?v=1738682766\"\u003e\u003cimg alt=\"DataSheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e DataSheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP109.pdf\"\u003e\u003cimg alt=\"Operation Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Operation Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Drawing_K30_K33_Revised8.pdf?v=1653005062\"\u003e\u003cimg alt=\"CO2 sensor drawing\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Dimensional Drawings (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/\/co2meters.com\/Documentation\/Other\/SenseairISO.pdf\"\u003e\u003cimg alt=\"Senseair ISO Certification\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0020_Sensor_Calibration_Procedure_2023.pdf?v=1706541759\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Sensor Calibration Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"technical-documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1702565512\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Web Application Using PHP and K30 DevKit (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN137-K30-sensor-raspberry-pi-Revised8.pdf?v=1653006660\"\u003e\u003c\/a\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca style=\"color: rgb(255, 42, 0);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1715030056\"\u003eArduino UART Instructions (pdf)\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN126-K3x-sensor-arduino-uart_2023.pdf?v=1715030056\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_144_SE_0018_Revised8_CO2Meter.pdf?v=1710164403\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eTroubleshooting Arduino or Raspberry Pi (pdf)\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch2\u003eAccessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"CO2Meter Gas Sensor Development Kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit \u003c\/strong\u003e\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca title=\"Gaslab data logging software\" href=\"https:\/\/www.co2meter.com\/pages\/downloads\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/gas-sensor-micro-pump\"\u003eSample Draw Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the components you need with a sample draw sensor to create a closed CO2 measurement system.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"View the Probe Enclosure for Development Kits\" href=\"\/products\/probe-enclosure-development-kit\"\u003e\u003cstrong\u003eProbe Enclosure\u003c\/strong\u003e\u003c\/a\u003e. Includes hydrophobic filters, protects the sensor when used in hostile environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"030-8-0010: K30-FS Fast Response 1% CO2 Sensor","offer_id":49030530334976,"sku":"030-8-0010","price":80.85,"currency_code":"USD","in_stock":true},{"title":"CM-0126: K30 FR Sensor Development Kit","offer_id":49030530367744,"sku":"CM-0126","price":415.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/030-8-0010K30FRFastResponse10_000ppmCO2SensorlCO2Meter.jpg?v=1784471444","url":"https:\/\/alotechparts.com\/products\/030-8-0010-k30-fr-fast-response-10000-ppm-co2-sensor","provider":"Alo Tech Solutions","version":"1.0","type":"link"}