{"product_id":"planet-igs-6325-24up4x-ip30-19-rack-mountable-industrial-l3-managed-poe-switch-24","title":"Planet IGS-6325-24UP4X IP30 19\" Rack Mountable Industrial L3 Managed PoE Switch, 24","description":"\u003cp\u003e\u003cstrong\u003eAdvanced Layer 3 Manageable PoE++ Solution for Harsh Environments \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIGS-6325-24UP4X L3 Industrial Managed PoE++ Switch\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance networking solution that provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 10\/100\/1000BASE-T 802.3bt PoE++ ports\u003c\/strong\u003e. Each port can deliver\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eup to 95 watts of power\u003c\/strong\u003e. In addition, the switch has\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e4 10G SFP+ ports\u003c\/strong\u003e, all housed in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e19-inch  1U rack-mount case\u003c\/strong\u003e. With its 10Gbps uplink, this switch can handle extremely large amounts of data in a secure topology, linking to an industrial backbone or high-capacity servers.\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X also has user-friendly yet advanced IPv6\/IPv4 management interfaces, abundant L2\/L4 switching functions,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLayer 3 OSPFv2, v3 \u0026amp; RIPv2 dynamic routing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapability, and advanced\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eITU-G.8032 ERPS Ring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etechnology to improve the rapid self-recovery capability. Furthermore, PLANET intelligent PoE functions enable controlling the PoE IP surveillance and wireless network applications. The switch is designed to operate reliably, stably, and quietly within a temperature range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40 to 75 degrees Celsius\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"400\" width=\"1000\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/edm_IGS-6325-24UP4X.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Power and Full-speed Data Delivered over 4-pair UTP Cabling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X meets the standards of IEEE 802.bt PoE++ technology and has a total power capacity of 1440 watts. This allows it to supply up to 95 watts of power to each remote PoE-compliant powered device (PD) using all four pairs of standard Cat5e\/6 Ethernet cabling, ensuring high power and full-speed data delivery. Compared to the conventional 802.3at PoE+, it offers triple power capacity, making it the perfect solution for higher power consuming PDs, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePoE PTZ speed dome cameras\u003c\/li\u003e\n\u003cli\u003eNetwork devices \u003c\/li\u003e\n\u003cli\u003eThin clients\u003c\/li\u003e\n\u003cli\u003eAIO (all-in-one) touch PCs, point of sale (POS) and information kiosks\u003c\/li\u003e\n\u003cli\u003eRemote digital signage displays\u003c\/li\u003e\n\u003cli\u003ePoE lightings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"359\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/IGS-6325-24UP4X-1.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e802.3bt PoE++ and Advanced PoE Power Output Mode Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo meet the demand for supplying stable PoE power to various powered devices, the IGS-6325-24UP4X switch offers five different PoE power output modes for selection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e90W 802.3bt PoE++ Power Output Mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e95W UPOE Power Output Mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e95W Force Power Output Mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e36W End-span PoE Power Output Mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e36W Mid-span PoE Power Output Mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eONVIF Support Allows Effective and Centralized Control Over IP-based Security Products\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X switch offers ONVIF support as part of its versatile feature set for seamless integration with IP surveillance cameras. Through the switch's web GUI, users can easily search for and display all ONVIF-compliant devices on their LAN.\u003c\/p\u003e\n\u003cp\u003eUsers can also upload floor plans to the switch and place IP surveillance cameras on the plan for more intuitive planning and faster inspection in the future. Additionally, the web GUI provides real-time surveillance information, online\/offline status, and the ability to remotely reboot cameras.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"371\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/IGS-6325-24UP4X-2.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Alive Check for Powered Devices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X can be configured to monitor the status of connected powered devices (PDs) in real time through ping action. If a PD stops working and responding, the IGS-6325-24UP4X will recycle the PoE port power and bring the PD back to working condition. This greatly enhances reliability, as the assigned PoE port automatically reboots the PD, reducing the administrator's management burden.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"336\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/Common_PD-Alive-Check.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePoE Scheduling to Save Energy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBy implementing the \"PoE schedule\" function, businesses can reduce their energy consumption during non-business hours or periods of low network usage. This not only helps to reduce energy costs but also minimizes the overall carbon footprint of the organization.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the IGS-6325-24UP4X's PoE scheduling feature provides a convenient and easy-to-use interface for managing power usage. The user can easily set the time intervals for each PoE port, allowing for more efficient power management.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"253\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/Common_PoE-Schedule-for-Energy-Saving.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScheduled Power Recycling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X enables connected PoE IP cameras or PoE wireless access points to reboot at a specific time each week. This will reduce the chance of IP camera or AP crashes resulting from buffer overflow.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"337\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/Common_Scheduled-Power-Recycling.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 Routing Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X allows administrators to boost network efficiency by configuring Layer 3 IPv4\/IPv6 VLAN static routing manually or automatically through the\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eRouting Information Protocol (RIP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOpen Shortest Path First (OSPF)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esettings.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRIP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses hop count as a routing metric and prevents routing loops by setting a limit on the number of hops allowed in a path from source to destination.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOSPF\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an interior dynamic routing protocol for autonomous systems based on link state. The protocol creates a database of link states by exchanging link states among Layer 3 switches and then uses the Shortest Path First algorithm to generate a route table based on that database.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReliable 10Gb Ethernet Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe emergence of 10G Ethernet marks a significant advancement in Ethernet technology. The IGS-6325-24UP4X is a powerful networking device that offers\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003efour 10G SFP+ slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapable of supporting three different speeds. These slots can operate at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10GBASE-SR\/LR or 1G\/2.5GBASE-SX\/LX backwards\u003c\/strong\u003e, providing administrators with flexibility in choosing the most suitable SFP\/SFP+ transceiver based on the required transmission distance and speed. With ample bandwidth and robust processing capacity, the IGS-6325-24UP4X provides an efficient solution for administrators seeking to enhance their network infrastructure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCybersecurity Network Solution to Minimize Security Risks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSHv2 and TLSv1.2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocols to provide strong protection against advanced threats. It includes a range of cybersecurity features such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDHCP Snooping\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP Source Guard\u003c\/strong\u003e,\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eARP Inspection Protection\u003c\/strong\u003e,\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e802.1x port-based, and MAC-based network access control, RADIUS and TACACS+\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euser accounts management,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSNMPv3 authentication\u003c\/strong\u003e, and more to provide a comprehensive security solution.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"137\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/Common_Secure-Management.png\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X Series supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eITU-T G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etechnology, Spanning Tree Protocol (802.1s MSTP), and\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003edual power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einput system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a simple Ring network, the recovery time of data link can be as fast as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10ms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"462\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/IGS-6325-24P4X_24P4S-2.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEffective Alarm Alert for Better Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X supports a Fault Alarm feature that can alert users when there is an issue with the switches. This feature saves time and resources by quickly identifying the problem, eliminating the need for laborious troubleshooting efforts.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"285\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/IGS-6325-24P4X_24P4S-6.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Input and Digital Output for External Alarm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X supports digital input and output on its front panel. These features allow users to detect and log the status of external devices, such as door intrusion detectors, using digital input. It also enables the sending of an event alarm to administrators. Digital output can be used to alert administrators when the IGS-6325-24UP4X experiences a link down, link up, or power failure.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"678\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/IGS-6325-24P4X_24P4S-7.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X is capable of advanced Layer 2 switch management functions, including dynamic port\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003elink aggregation, 802.1Q tagged VLAN, Q-in-Q VLAN, private VLAN, Multiple Spanning Tree Protocol (MSTP), Layer 2 to Layer 4 QoS, bandwidth control, IGMP snooping, and MLD snooping\u003c\/strong\u003e. By aggregating supporting ports, the IGS-6325-24UP4X can operate up to 14 high-speed trunk groups with up to 16 ports, with fail-over support.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"217\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/Common_Robust-Layer-2-Features.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the supported\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocol, the IGS-6325-24UP4X can easily integrate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCADA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoperating information\u003c\/strong\u003e,\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eport information\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication status\u003c\/strong\u003e, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1588 Time Protocol for Industrial Computing Networks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-24UP4X is ideal for implementing Precision Time Protocol (PTP) applications as a transparent clock. It can play an important role in an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEEE 1588\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand Synchronous Ethernet network by supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMEF service\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivery and timing over packet solutions.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"355\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49635\/IGS-6325-24P4X_24P4S-8.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Port \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 10\/100\/1000BASE-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGigabit Ethernet RJ45 ports with\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eIEEE 802.3bt PoE++\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInjector function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 10GBASE-SR\/LR SFP+\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eslots, backward compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1G\/2.5GBASE-X SFP\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOne RJ45-to-RS232 console interface for basic management and setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIEEE 802.3bt Power over Ethernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompliance with IEEE 802.3bt Type-4 PoE++ standard\u003c\/li\u003e\n\u003cli\u003eBackward compatibility with IEEE 802.3af\/at PD device\u003c\/li\u003e\n\u003cli\u003ePower up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEEE 802.3bt PoE++ devices (60W) using dual power input\u003c\/li\u003e\n\u003cli\u003eEach port has a maximum power output of 95 watts (Using the maximum amount may reduce the number of available ports.) \u003c\/li\u003e\n\u003cli\u003eTotal of 1440-watt PoE budget\n\u003cul\u003e\n\u003cli\u003eA single power input can provide a power budget of up to 720W.\u003c\/li\u003e\n\u003cli\u003eTwo power inputs can provide a power budget of up to 1,440W.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDetects powered devices (PD) automatically.\u003c\/li\u003e\n\u003cli\u003eCircuit protection prevents power interference between ports.\u003c\/li\u003e\n\u003cli\u003ePower feeding up to 100m\u003c\/li\u003e\n\u003cli\u003ePoE management features\n\u003cul\u003e\n\u003cli\u003eTotal PoE power budget control\u003c\/li\u003e\n\u003cli\u003ePer port PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE admin-mode control\u003c\/li\u003e\n\u003cli\u003ePoE port power feeding priority\u003c\/li\u003e\n\u003cli\u003ePer PoE port power limit\u003c\/li\u003e\n\u003cli\u003ePD classification detection\u003c\/li\u003e\n\u003cli\u003ePoE extension mode to support power feeding up to a maximum distance of 160 meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntelligent PoE features\n\u003cul\u003e\n\u003cli\u003eTemperature threshold setting\u003c\/li\u003e\n\u003cli\u003ePoE usage threshold setting\u003c\/li\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Protocol\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModbus TCP for real-time monitoring in the SCADA system\u003c\/li\u003e\n\u003cli\u003eSupports IEEE 1588v2 PTP (Precision Time Protocol) transparent clock mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Design and Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe IP30 metal housing is designed to be rack-mountable in a 19-inch rack.\u003c\/li\u003e\n\u003cli\u003eThe front-accessible and fan-less design enables convenient access and quiet operation.\u003c\/li\u003e\n\u003cli\u003eDual 48~54V DC power input with reverse polarity protection\u003c\/li\u003e\n\u003cli\u003e-40 to 75 degrees C operating temperature \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Input and Digital Output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 digital inputs (DI)\u003c\/li\u003e\n\u003cli\u003e2 digital outputs (DO)\u003c\/li\u003e\n\u003cli\u003eIntegrate sensors into auto alarm system\u003c\/li\u003e\n\u003cli\u003eTransfer alarms to IP networks via email and SNMP trap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 IP Routing Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 dynamic routing protocol supports RIPv1\/v2 and OSPFv2\u003c\/li\u003e\n\u003cli\u003eIPv6 dynamic routing protocol supports OSPFv3.\u003c\/li\u003e\n\u003cli\u003eIPv4\/IPv6 hardware static routing\u003c\/li\u003e\n\u003cli\u003eRouting interface provides per VLAN routing mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance of Store-and-Forward architecture, and runt\/CRC filtering eliminates erroneous packets to optimize the network bandwidth\u003c\/li\u003e\n\u003cli\u003eStorm Control support\n\u003cul\u003e\n\u003cli\u003eBroadcast\/Multicast\/Unicast\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVLAN\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eProvider Bridging (VLAN Q-in-QIEEE 802.1ad) \u003c\/li\u003e\n\u003cli\u003ePrivate VLAN Edge (PVE)\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eMAC-based VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN \u003c\/li\u003e\n\u003cli\u003eGVRP (GARP VLAN Registration Protocol)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpanning Tree Protocol\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Guard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLink Aggregation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003cli\u003eMaximum 14 trunk groups with 16 ports per trunk group \u003c\/li\u003e\n\u003cli\u003eUp to 104Gbps bandwidth (duplex mode) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports port mirroring for many-to-one connections.\u003c\/li\u003e\n\u003cli\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port \u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP) \u003c\/li\u003e\n\u003cli\u003eSupports ITU G.8032 ERPS Ring (Ethernet Ring Protection Switching).\u003c\/li\u003e\n\u003cli\u003eCompatible with Cisco's uni-directional link detection (UDLD), which monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuality of Service\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIngress shaper and egress rate limit per port bandwidth control\u003c\/li\u003e\n\u003cli\u003e8 priority queues on all switch ports\u003c\/li\u003e\n\u003cli\u003eTraffic classification\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1p CoS\u003c\/li\u003e\n\u003cli\u003eToS\/DSCP\/IP Precedence of IPv4\/Ipv6 packets\u003c\/li\u003e\n\u003cli\u003eIP TCP\/UDP port number\u003c\/li\u003e\n\u003cli\u003eTypical network application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003c\/li\u003e\n\u003cli\u003eSupports QoS and In\/Out bandwidth control on each port\u003c\/li\u003e\n\u003cli\u003eTraffic-policing on the switch port\u003c\/li\u003e\n\u003cli\u003eDSCP remarking \u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMulticast\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports IPv4 IGMP snooping v1, v2 and v3\u003c\/li\u003e\n\u003cli\u003eSupports IPv6 MLD snooping v1 and v2\u003c\/li\u003e\n\u003cli\u003eQuerier mode support\u003c\/li\u003e\n\u003cli\u003eIPv4 IGMP snooping port filtering\u003c\/li\u003e\n\u003cli\u003eIPv6 MLD snooping port filtering\u003c\/li\u003e\n\u003cli\u003eMVR (Multicast VLAN Registration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuthentication\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1x port-based \/ MAC-based network access authentication\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1x authentication with guest VLAN\u003c\/li\u003e\n\u003cli\u003eGuest VLAN assigns clients to a restricted VLAN with limited services.\u003c\/li\u003e\n\u003cli\u003eBuilt-in RADIUS client to co-operate with the RADIUS servers\u003c\/li\u003e\n\u003cli\u003eTACACS+ login users access authentication\u003c\/li\u003e\n\u003cli\u003eRADIUS\/TACACS+ users access authentication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess Control List\n\u003cul\u003e\n\u003cli\u003eIP-based Access Control List (ACL)\u003c\/li\u003e\n\u003cli\u003eMAC-based Access Control List\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSource MAC\/IP address binding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDHCP Snooping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto filter un-trusted DHCP messages\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic ARP Inspection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ediscards ARP packets with invalid MAC address to IP address binding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Source Guard\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprevents IP spoofing attacks\u003c\/li\u003e\n\u003cli\u003eIP address access management to prevent unauthorized intruder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 and IPv6 dual stack management\u003c\/li\u003e\n\u003cli\u003eSwitch Management Interfaces\n\u003cul\u003e\n\u003cli\u003eConsole\/ and elnet Command Line Interface \u003c\/li\u003e\n\u003cli\u003eHTTP\/HTTPs Web switch management\u003c\/li\u003e\n\u003cli\u003eSNMP v1 and v2c switch management\u003c\/li\u003e\n\u003cli\u003eSSHv2, TLSv1.2 and SNMP v3 secure access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSNMP Management\n\u003cul\u003e\n\u003cli\u003eFour RMON groups (history, statistics, alarms, and events) \u003c\/li\u003e\n\u003cli\u003eSNMP trap for interface Link Up and Link Down notification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIPv6 IP address\/NTP\/DNS management\u003c\/li\u003e\n\u003cli\u003eBuilt-in Trivial File Transfer Protocol (TFTP) client\u003c\/li\u003e\n\u003cli\u003eBOOTP and DHCP for IP address assignment\u003c\/li\u003e\n\u003cli\u003eSystem Maintenance\n\u003cul\u003e\n\u003cli\u003eFirmware upload\/download via HTTP\/TFTP\u003c\/li\u003e\n\u003cli\u003eReset button for system reboot or reset to factory default\u003c\/li\u003e\n\u003cli\u003eDual Images\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDHCP Functions:\n\u003cul\u003e\n\u003cli\u003eDHCP Relay\u003c\/li\u003e\n\u003cli\u003eDHCP Option82\u003c\/li\u003e\n\u003cli\u003eDHCP Server\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser Privilege levels control\u003c\/li\u003e\n\u003cli\u003eNetwork Time Protocol (NTP)\u003c\/li\u003e\n\u003cli\u003eNetwork Diagnositc\n\u003cul\u003e\n\u003cli\u003eSFP-DDM (Digital Diagnostic Monitor)\u003c\/li\u003e\n\u003cli\u003eICMPv6\/ICMPv4 Remote Ping\u003c\/li\u003e\n\u003cli\u003eCable diagnostic technology provides the mechanism to detect and report potential cabling issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSMTP\/Syslog remote alarm\u003c\/li\u003e\n\u003cli\u003eSystem Log\u003c\/li\u003e\n\u003cli\u003ePLANET Smart Discovery Utility for deployment management\u003c\/li\u003e\n\u003cli\u003ePLANET UNI-NMS (Universal Network Management) and CloudViewer app for deployment management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"table table-sm table-bordered-bone table-striped-blue table-header-theme-blue table-header-no-border\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eHardware Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e24 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSFP+ Slots\u003c\/td\u003e\n\u003ctd\u003e4 10GBASE-SR\/LR SFP+ interfaces (Port-25 to Port-28)\u003cbr\u003eBackward compatible with 1G\/2.5GBASE-SX\/LX\/BX SFP transceivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Injector Port\u003c\/td\u003e\n\u003ctd\u003e24 ports with 802.3bt PoE++ injector function from Port-1 to Port-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConsole\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45-to-RS232 serial port (115200, 8, N, 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003eContact 4KVDC; Air 8KVDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e6-contact barrier terminal block for power input\u003cbr\u003eContact 1\/2 for Power 1, Contact 3\/4 for fault alarm, Contact 5\/6 for Power 2\u003cbr\u003eRemovable 6-pin terminal block for DI\/DO interface\u003cbr\u003ePin 1\/2 for DI 0 \u0026amp; 1, Pin 3\/4 for DO 0 \u0026amp; 1, Pin 5\/6 for GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eOne relay output for power failure. Alarm relay current carry ability: 3A @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDigital Input (DI)\u003c\/td\u003e\n\u003ctd\u003e2 digital input (DI):\u003cbr\u003e　Level 0: -24V~2.1V (±0.1V)\u003cbr\u003e　Level 1: 2.1V~24V (±0.1V)\u003cbr\u003e　Input load to 24VDC, 10mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDigital Output (DO)\u003c\/td\u003e\n\u003ctd\u003e2 digital output (DO):\u003cbr\u003e　Open collector to 24V DC, 100mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP30 metal case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eRack-mount kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSDRAM\u003c\/td\u003e\n\u003ctd\u003e512Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e64Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e440 x 300 x 44 mm, 1U height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4,051g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eDual 48~54V DC, 32A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e52VDC Input:\u003cbr\u003e　No Loading: 20.74W\/70.8BTU\/hr; Full Loading: 1,522W\/5,262.9BTU\/hr\u003cbr\u003e54VDC Input:\u003cbr\u003e　No Loading: 20.78W\/70.9BTU\/hr; Full Loading: 1,522W\/5,193.3BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eSystem:\u003c\/b\u003e\u003cbr\u003e　DC 1 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　DC 2 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Alarm (\u003cspan style=\"color: red;\"\u003e\u003cb\u003eRed\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Ring (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Ring Owner (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　DIDO (\u003cspan style=\"color: red;\"\u003e\u003cb\u003eRed\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003e10\/100\/1000T RJ45 PoE++ Interfaces (Port 1 to Port 24):\u003c\/b\u003e\u003cbr\u003e　bt PoE++ (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　af\/at PoE (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　1000 LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　100 LNK\/ACT (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003e1G\/2.5G\/10Gbps Fiber Interfaces (Port 25 to Port 28):\u003c\/b\u003e\u003cbr\u003e　1G\/2.5Gbps LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　10Gbps LNK\/ACT (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitching Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e128Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eThroughput (packet per second)\u003c\/td\u003e\n\u003ctd\u003e95.2Mpps@ 64 bytes packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAddress Table\u003c\/td\u003e\n\u003ctd\u003e16K entries, automatic source address learning and aging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e32M bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3x pause frame for full duplex\u003cbr\u003eBack pressure for half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e10K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePower Over Ethernet\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3bt PoE++ Type-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Supply Type\u003c\/td\u003e\n\u003ctd\u003eEnd-span\u003cbr\u003eMid-span\u003cbr\u003eBT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Output\u003c\/td\u003e\n\u003ctd\u003ePer port 48V ~ 54VDC\u003cbr\u003e　802.3bt Type-4 mode: maximum 95 watts\u003cbr\u003e　802.3bt Type-3 mode: maximum 60 watts\u003cbr\u003e　End-span mode: maximum 36 watts\u003cbr\u003e　Mid-span mode: maximum 36 watts\u003cbr\u003e　Force mode: maximum 95 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Pin Assignment\u003c\/td\u003e\n\u003ctd\u003e802.3bt\/UPoE: 1\/2(-), 3\/6(+), 4\/5(+), 7\/8(-)\u003cbr\u003e802.3at PoE: End-span: 1\/2(-), 3\/6(+)\u003cbr\u003e802.3at PoE: Mid-span: 4\/5(+), 7\/8(-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003eSingle power input: 720W maximum (depending on power input)\u003cbr\u003eDual power input: 1,440W maximum (depending on power input)\u003cbr\u003e\u003cb\u003eNote: The DC voltage of the dual power input must match, such as dual 54V.\u003c\/b\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNumber of 90W 802.3bt Type-4 PDs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNumber of 60W 802.3bt Type-3 PDs\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNumber of 30W 802.3at Type-2 PDs\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePoE Management Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnhanced PoE Mode\u003c\/td\u003e\n\u003ctd\u003eStandard\/Legacy\/Force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Management\u003c\/td\u003e\n\u003ctd\u003ePD Alive Check\u003cbr\u003eScheduled Power Recycling\u003cbr\u003ePoE Schedule\u003cbr\u003ePoE Usage Monitoring\u003cbr\u003ePoE Extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eActive PoE Device Live Detection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Recycling\u003c\/td\u003e\n\u003ctd\u003eYes, daily or predefined schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Schedule\u003c\/td\u003e\n\u003ctd\u003e4 schedule profiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Extend Mode\u003c\/td\u003e\n\u003ctd\u003eYes, max. up to 160 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 3 Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIP Interfaces\u003c\/td\u003e\n\u003ctd\u003eMax. 128 VLAN interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Table\u003c\/td\u003e\n\u003ctd\u003eMax. 128 static routing entries\u003cbr\u003eMax. 4K routing table entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eIPv4 RIPv1\/v2 dynamic routing\u003cbr\u003eIPv4 OSPFv2 dynamic routing\u003cbr\u003eIPv6 OSPFv3 dynamic routing\u003cbr\u003eIPv4 hardware static routing\u003cbr\u003eIPv6 hardware static routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 2 Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003ePort disable\/enable\u003cbr\u003eAuto-negotiation 10\/100\/1000Mbps full and half duplex mode selection\u003cbr\u003eFlow control disable\/enable\u003cbr\u003ePort link capability control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Status\u003c\/td\u003e\n\u003ctd\u003eDisplay each port’s speed duplex mode, link status, flow control status,\u003cbr\u003eauto negotiation status, trunk status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd\u003eTX \/ RX \/ Both\u003cbr\u003eMany-to-1 monitor\u003cbr\u003eRMirror – Remote Switched Port Analyzer (Cisco RSPAN)\u003cbr\u003eSupports up to 5 sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Q tag-based VLAN\u003cbr\u003eIEEE 802.1ad Q-in-Q tunneling\u003cbr\u003ePrivate VLAN Edge (PVE)\u003cbr\u003eMAC-based VLAN\u003cbr\u003eProtocol-based VLAN\u003cbr\u003eVoice VLAN\u003cbr\u003eMVR (Multicast VLAN Registration)\u003cbr\u003eGVRP (GARP VLAN Registration Protocol)\u003cbr\u003eUp to 4K VLAN groups, out of 4096 VLAN IDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ad LACP\/static trunk\u003cbr\u003eSupports 14 trunk groups with 16 ports per trunk group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eSupports 7 MSTP instances\u003cbr\u003eBPDU Guard, BPDU filtering and BPDU transparent\u003cbr\u003eRoot Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv4 IGMP (v1\/v2\/v3) snooping\u003cbr\u003eIPv4 IGMP querier mode support\u003cbr\u003eUp to 2K multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv6 MLD (v1\/v2) snooping\u003cbr\u003eIPv6 MLD querier mode support\u003cbr\u003eUp to 512 multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBandwidth Control\u003c\/td\u003e\n\u003ctd\u003ePer port bandwidth control\u003cbr\u003e　Ingress: 10Kbps~13000Mbps\u003cbr\u003e　Egress: 100Kbps~13000Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRing\u003c\/td\u003e\n\u003ctd\u003eSupports ERPS, and complies with ITU-T G.8032\u003cbr\u003eRecovery time \u0026lt; 10ms @ 3 nodes\u003cbr\u003eRecovery time \u0026lt; 50ms @ 16 nodes\u003cbr\u003eSupports Major ring and sub-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 PTP (Precision Time Protocol)\u003cbr\u003e　Peer-to-peer transparent clock\u003cbr\u003e　End-to-end transparent clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eQoS\u003c\/td\u003e\n\u003ctd\u003eTraffic classification based, strict priority and WRR\u003cbr\u003e8-level priority for switching\u003cbr\u003e　Port number\u003cbr\u003e　802.1p priority\u003cbr\u003e　802.1Q VLAN tag\u003cbr\u003e　DSCP\/TOS field in IP packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSecurity Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAccess Control List\u003c\/td\u003e\n\u003ctd\u003eIP-based ACL\/MAC-based ACL\u003cbr\u003e　ACL based on:\u003cbr\u003e　MAC Address\u003cbr\u003e　IP Address\u003cbr\u003e　Ethertype\u003cbr\u003e　Protocol Type\u003cbr\u003e　VLAN ID\u003cbr\u003e　DSCP\u003cbr\u003e　802.1p Priority\u003cbr\u003eUp to 512 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003ePort security\u003cbr\u003eIP source guard, up to 512 entries\u003cbr\u003eDynamic ARP inspection, up to 1K entries\u003cbr\u003eCommand line authority control based on user level\u003cbr\u003eStatic MAC address, up to 64 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAAA\u003c\/td\u003e\n\u003ctd\u003eRADIUS client\u003cbr\u003eTACACS+ client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNetwork Access Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x port-based network access control\u003cbr\u003eMAC-based authentication\u003cbr\u003eLocal\/RADIUS authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eManagement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eConsole; Telnet; Web browser; SNMP v1, v2c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eSSHv2, TLSv1.2, SNMP v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSystem Management\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade by HTTP protocol through Ethernet network\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eRemote Syslog\u003cbr\u003eSystem log\u003cbr\u003eLLDP protocol\u003cbr\u003eNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003cbr\u003ePLANET CloudViewer app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC 1213 MIB-II\u003cbr\u003eRFC 1493 Bridge MIB\u003cbr\u003eRFC 1643 Ethernet MIB\u003cbr\u003eRFC 2863 Interface MIB\u003cbr\u003eRFC 2665 Ether-Like MIB\u003cbr\u003eRFC 2819 RMON MIB (Groups 1, 2, 3 and 9)\u003cbr\u003eRFC 2737 Entity MIB\u003cbr\u003eRFC 2618 RADIUS Client MIB\u003cbr\u003eRFC 2863 IF-MIB\u003cbr\u003eRFC 2933 IGMP-STD-MIB\u003cbr\u003eRFC 3411 SNMP-Frameworks-MIB\u003cbr\u003eRFC 4292 IP Forward MIB\u003cbr\u003eIEEE 802.1X PAE\u003cbr\u003eRFC 4293 IP MIB\u003cbr\u003eRFC 4836 MAU-MIB\u003cbr\u003eIEEE 802.1X PAE\u003cbr\u003eLLDP\u003cbr\u003ePowerEthernet MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandards Conformance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A\u003cbr\u003eCE:\u003cbr\u003e　EN55032\u003cbr\u003e　EN55035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 10BASE-T\u003cbr\u003eIEEE 802.3u 100BASE-TX\/100BASE-FX\u003cbr\u003eIEEE 802.3z Gigabit SX\/LX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE 802.3ae 10Gigabit Ethernet\u003cbr\u003eIEEE 802.3x flow control and back pressure\u003cbr\u003eIEEE 802.3ad port trunk with LACP\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE 802.1p Class of Service\u003cbr\u003eIEEE 802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1ad Q-in-Q VLAN stacking\u003cbr\u003eIEEE 802.1X Port Authentication Network Control\u003cbr\u003eIEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3ah OAM\u003cbr\u003eIEEE 802.3af Power over Ethernet\u003cbr\u003eIEEE 802.3at Power over Ethernet Plus\u003cbr\u003eIEEE 802.3bt Power over Ethernet Plus Plus\u003cbr\u003eIEEE 1588 PTPv2\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 783 TFTP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eRFC 3376 IGMP version 3\u003cbr\u003eRFC 2710 MLD version 1\u003cbr\u003eRFC 3810 MLD version 2\u003cbr\u003eRFC 2328 OSPF v2\u003cbr\u003eRFC 5340 OSPF v3\u003cbr\u003eRFC 2453 RIP v2\u003cbr\u003eITU G.8032 ERPS Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEnvironment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ~ 75 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ~ 85 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":48892939665664,"sku":"IGS-6325-24UP4X","price":2118.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/box_IGS-6325-24UP4Xv1.1.jpg?v=1782490922","url":"https:\/\/alotechparts.com\/es\/products\/planet-igs-6325-24up4x-ip30-19-rack-mountable-industrial-l3-managed-poe-switch-24","provider":"Alo Tech Solutions","version":"1.0","type":"link"}