{"product_id":"o2-a2-alphasense-25-2-year-oxygen-smart-ec-sensor","title":"O2-A2 Alphasense 25% 2 Year Oxygen Smart EC Sensor","description":"\u003cp\u003e\u003cspan\u003eThe \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong\u003eO2-A2 Alphasense Oxygen Sensor\u003c\/strong\u003e\u003c\/span\u003e is designed to monitor 25% oxygen levels by volume. \u003c\/span\u003eThe sensor is most sought after as a replacement sensor for handheld gas detectors that use the O2-A2 sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-teams=\"true\"\u003e\u003ci\u003e\u003cstrong\u003eNote: Once an electrochemical (EC) sensor is purchased from CO2Meter.com and the sealed packaging is opened or the sensor module is installed, it is no longer eligible for return due to the limited operational lifespan that begins upon activation.\u003c\/strong\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cspan data-teams=\"true\"\u003e\u003ci\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(239, 6, 6);\"\u003e*\u003cem\u003e*Please Note: MOQ 10pcs - 2-4 week lead time**\u003c\/em\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrochemical Sensor measures up to 25% Oxygen\u003c\/li\u003e\n\u003cli\u003eBarometric Pressure, Temperature and % Relative Humidity Sensors\u003c\/li\u003e\n\u003cli\u003eSmart EC board Adds RS485 with Optional \u003ca href=\"\/es\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 cable\"\u003eRS485 Cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasy Integration; Compact \u0026amp; Low Power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eO2-A2 \u003c\/span\u003eSensor Only\u003c\/strong\u003e – Sensor only.  Designed for integration into high-volume OEM products or as a replacement oxygen sensor in these 4 gas analyzers:\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCan be used as replacement sensors for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBW Technologies GasAlert MicroClip XT\u003c\/li\u003e\n\u003cli\u003eBW Technologies GasAlert Max XT-II\u003c\/li\u003e\n\u003cli\u003eBW Technologies GasAlert Micro 5 PID\u003c\/li\u003e\n\u003cli\u003eBW Technologies GasAlert Quattro\u003c\/li\u003e\n\u003cli\u003eBW Technologies GasAlert Extreme GAXT-DL-2\u003c\/li\u003e\n\u003cli\u003eBW Technologies GasAlert Extreme GAXT-DL-B-2\u003c\/li\u003e\n\u003cli\u003eBW Equivalent part no. \u003cspan\u003eSR-X10-C1\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMSA Solaris Orion Altair 4,5 (not 4X or 5X)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCityTech 4OX-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-20.9% oxygen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 80-120 uA @ 20.9% O2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 15 sec. t90 (s) from 20.9% to 0% O2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e 0.6% O2 deviation @ 10% O2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput drift:\u003c\/strong\u003e \u0026lt; 1% change @ 3 months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating life:\u003c\/strong\u003e \u0026gt; 24 months until 85% original Output of 20.9% O2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output:\u003c\/strong\u003e 0-3VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\/Mechanical\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (sensor):\u003c\/strong\u003e 17.4mm x 20.3mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (sensor + PCB):\u003c\/strong\u003e 40mm X 25mm x 29mm (LxWxH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 3.3-5.5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 10ma peak, \u0026lt; 3mW average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/ametekcdn.azureedge.net\/mediafiles\/project\/oneweb\/oneweb\/alphasense\/products\/datasheets\/alphasense_o2-a2_datasheet_en_1.pdf?revision:b9920a9a-1297-49d7-bdb7-3ec5f47cbcf0\"\u003e\u003cimg alt=\"Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/ametekcdn.azureedge.net\/mediafiles\/project\/oneweb\/oneweb\/alphasense\/products\/datasheets\/alphasense_o2-a2_datasheet_en_1.pdf?revision:b9920a9a-1297-49d7-bdb7-3ec5f47cbcf0\" title=\"Datasheet for the O2-A2\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual-EC200-Sensors_rev_R.pdf?v=1650730719\"\u003e\u003cimg alt=\"Documentation\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eFree Easy-to-use GasLab® Software\u003c\/h3\u003e\n\u003cp\u003eThe Smart EC board uses GasLab® software for setup, calibration, data logging, and real-time data analysis. GasLab® makes it easy to export data into a .CSV file that can be imported into any industry-standard software or spreadsheet. GasLab® runs on Windows XP or higher, and free to use with our products.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/es\/pages\/downloads\"\u003e\u003cimg alt=\"Download Latest Software Here\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/download-drivers.gif?1253980035\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eSystem Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWindows XP SP2 or newer\u003c\/li\u003e\n\u003cli\u003eMicrosoft .Net 3.5 Runtime Libraries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/es\/products\/co2meter-sensor-tube-cap\"\u003eTube Cap Adapters\u003c\/a\u003e \u003c\/strong\u003eeasily convert 20mm standard gas sensors from diffusion to sampling sensors. \u003cspan\u003eMolded polymer. \u003c\/span\u003e\u003cstrong\u003eTube cap adapters are not pre-installed\u003c\/strong\u003e\u003cspan\u003e. For accurate results you must \u003c\/span\u003e\u003ca href=\"http:\/\/co2meters.com\/Documentation\/Other\/Tube%20Cap%20Installation%20Procedure_rev_CO2Meter.pdf\"\u003emount the tube cap permanently\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/es\/products\/rs485-cable-ec-mx-sensor-development-kits\" title=\"RS485 Modbus cable\"\u003e\u003cstrong\u003eRS485 Cable\u003c\/strong\u003e\u003c\/a\u003e. Custom USB cable enables RS485 communication to GasLab Software for EC Sensor Board and Development Kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/es\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003e\u003cstrong\u003eMicro-Pump Kit\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eincludes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/es\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion Tubing\u003c\/a\u003e \u003c\/strong\u003eis a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/es\/products\/gas-sampling-pump\"\u003e\u003cstrong\u003eMicro Gas Sampling Pumps\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eprovide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"AlphaSense","offers":[{"title":"O2-A2 Alphasense 25% 2 Year Oxygen Smart EC Sensor","offer_id":49030527156480,"sku":"O2-A2","price":127.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/O2-A2Alphasense25_2YearOxygenSmartECSensorlCO2Meter.jpg?v=1784471398","url":"https:\/\/alotechparts.com\/es\/products\/o2-a2-alphasense-25-2-year-oxygen-smart-ec-sensor","provider":"Alo Tech Solutions","version":"1.0","type":"link"}