{"product_id":"nscomm-mpo-16f-apc-to-2xmpo-8f-apc-breakout-cables-8-fibers-multimode-om4-ofnr-crossover","title":"NSComm MPO 16F APC to 2xMPO 8F APC Breakout Cables, 8 Fibers, Multimode (OM4), OFNR, Crossover","description":"\u003ch3 data-end=\"110\" data-start=\"96\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-end=\"676\" data-start=\"112\"\u003eThe NSComm MPO 16F APC to 2xMPO 8F APC breakout cable is a high-density OM4 multimode splitter solution engineered for 400G\/800G data center architectures. With one 16-fiber MPO-16 APC (Female) trunk breaking out to two 8-fiber MPO-8 APC (Female) legs, this assembly supports 16-fiber parallel optics in a compact, factory-terminated form factor that simplifies high-speed backbone design. The MPO-16 APC end features an 8-degree angled polish to deflect internal back reflections away from the transceiver, helping preserve signal integrity at very high line rates.\u003c\/p\u003e\n\u003cp data-end=\"1212\" data-start=\"678\"\u003eBuilt with bend-insensitive OM4 50\/125 μm multimode fiber and a riser-rated OFNR jacket, this crossover breakout cable is purpose-built for linking two 400G QSFP-DD\/OSFP multimode transceivers to a single 800G QSFP-DD optics port in high-speed fiber links. Compared with deploying separate breakout cassettes, MPO-based breakout cables reduce the number of mated interfaces, resulting in lower overall insertion loss, reduced latency, and lower material and installation costs, ideal for hyperscale and large enterprise data centers.\u003c\/p\u003e\n\u003cp data-end=\"1398\" data-start=\"1214\"\u003eNeed help validating crossover polarity, channel mapping, or compatibility with your 400G\/800G SR8 optics? Contact us now and our team will help review your design before deployment.\u003c\/p\u003e\n\u003ch4 data-end=\"1429\" data-start=\"1405\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cdiv class=\"_tableContainer_80l1q_1\"\u003e\n\u003cdiv class=\"_tableWrapper_80l1q_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"5015\" data-start=\"1431\"\u003e\n\u003cthead data-end=\"1559\" data-start=\"1431\"\u003e\n\u003ctr data-end=\"1559\" data-start=\"1431\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1466\" data-start=\"1431\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"1559\" data-start=\"1466\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"5015\" data-start=\"1688\"\u003e\n\u003ctr data-end=\"1815\" data-start=\"1688\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1722\" data-start=\"1688\"\u003eVendor Name\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1815\" data-start=\"1722\"\u003eNSComm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1943\" data-start=\"1816\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1850\" data-start=\"1816\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1943\" data-start=\"1850\"\u003eMPO 16F APC to 2xMPO 8F APC Multimode Breakout Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2071\" data-start=\"1944\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1978\" data-start=\"1944\"\u003eConnector A\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2071\" data-start=\"1978\"\u003eMPO-16 APC Female (Pinless) with Offset Key, Low Loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2199\" data-start=\"2072\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2106\" data-start=\"2072\"\u003eConnector B\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2199\" data-start=\"2106\"\u003e2 × MPO-8 APC Female (Pinless), Low Loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2327\" data-start=\"2200\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2234\" data-start=\"2200\"\u003ePolish Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2327\" data-start=\"2234\"\u003eAPC to APC, 8° angled endfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2455\" data-start=\"2328\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2362\" data-start=\"2328\"\u003eFiber Mode\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2455\" data-start=\"2362\"\u003eOM4 50\/125 μm Multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2583\" data-start=\"2456\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2490\" data-start=\"2456\"\u003eGlass Fiber\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2583\" data-start=\"2490\"\u003eBend-insensitive multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2711\" data-start=\"2584\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2618\" data-start=\"2584\"\u003eWavelength\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2711\" data-start=\"2618\"\u003e850 nm \/ 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2839\" data-start=\"2712\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2746\" data-start=\"2712\"\u003eFiber Count\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2839\" data-start=\"2746\"\u003e16 Fibers total (1×16F trunk to 2×8F breakout)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2967\" data-start=\"2840\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2874\" data-start=\"2840\"\u003ePolarity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2967\" data-start=\"2874\"\u003eCrossover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3095\" data-start=\"2968\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3002\" data-start=\"2968\"\u003e400G Ethernet Distance\u003c\/td\u003e\n\u003ctd data-end=\"3095\" data-start=\"3002\" data-col-size=\"md\"\u003eUp to 50\/100 m at 850 nm (application dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3223\" data-start=\"3096\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3130\" data-start=\"3096\"\u003e800G Ethernet Distance\u003c\/td\u003e\n\u003ctd data-end=\"3223\" data-start=\"3130\" data-col-size=\"md\"\u003eUp to 50 m at 850 nm (application dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3351\" data-start=\"3224\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3258\" data-start=\"3224\"\u003eCable Outside Diameter (OD)\u003c\/td\u003e\n\u003ctd data-end=\"3351\" data-start=\"3258\" data-col-size=\"md\"\u003e3.0 mm (trunk, typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3479\" data-start=\"3352\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3386\" data-start=\"3352\"\u003eCable Jacket\u003c\/td\u003e\n\u003ctd data-end=\"3479\" data-start=\"3386\" data-col-size=\"md\"\u003eRiser-rated, OFNR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3607\" data-start=\"3480\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3514\" data-start=\"3480\"\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd data-end=\"3607\" data-start=\"3514\" data-col-size=\"md\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3735\" data-start=\"3608\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3642\" data-start=\"3608\"\u003eBreakout Length\u003c\/td\u003e\n\u003ctd data-end=\"3735\" data-start=\"3642\" data-col-size=\"md\"\u003e0.5 m (typical breakout leg length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3863\" data-start=\"3736\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3770\" data-start=\"3736\"\u003eInstallation Tensile Load\u003c\/td\u003e\n\u003ctd data-end=\"3863\" data-start=\"3770\" data-col-size=\"md\"\u003e66 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3991\" data-start=\"3864\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3898\" data-start=\"3864\"\u003eTensile Strength\u003c\/td\u003e\n\u003ctd data-end=\"3991\" data-start=\"3898\" data-col-size=\"md\"\u003e60\/120 N (Long\/Short Term)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4119\" data-start=\"3992\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4026\" data-start=\"3992\"\u003eInsertion Loss\u003c\/td\u003e\n\u003ctd data-end=\"4119\" data-start=\"4026\" data-col-size=\"md\"\u003eLow Loss, ≤ 0.35 dB Max (Typ. 0.15 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4247\" data-start=\"4120\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4154\" data-start=\"4120\"\u003eReturn Loss\u003c\/td\u003e\n\u003ctd data-end=\"4247\" data-start=\"4154\" data-col-size=\"md\"\u003e≥ 45 dB (APC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4375\" data-start=\"4248\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4282\" data-start=\"4248\"\u003eAttenuation @ 850 nm\u003c\/td\u003e\n\u003ctd data-end=\"4375\" data-start=\"4282\" data-col-size=\"md\"\u003e≤ 2.3 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4503\" data-start=\"4376\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4410\" data-start=\"4376\"\u003eAttenuation @ 1300 nm\u003c\/td\u003e\n\u003ctd data-end=\"4503\" data-start=\"4410\" data-col-size=\"md\"\u003e≤ 0.6 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4631\" data-start=\"4504\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4538\" data-start=\"4504\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-end=\"4631\" data-start=\"4538\" data-col-size=\"md\"\u003e-10 to 60 °C (14 to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4759\" data-start=\"4632\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4666\" data-start=\"4632\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-end=\"4759\" data-start=\"4666\" data-col-size=\"md\"\u003e-10 to 70 °C (14 to 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"4887\" data-start=\"4760\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4794\" data-start=\"4760\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd data-end=\"4887\" data-start=\"4794\" data-col-size=\"md\"\u003eMPO interface standards, OM4\/MMF, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5015\" data-start=\"4888\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"4922\" data-start=\"4888\"\u003eApplications\u003c\/td\u003e\n\u003ctd data-end=\"5015\" data-start=\"4922\" data-col-size=\"md\"\u003e2×400G to 1×800G fanout, parallel MM backbone, high-speed leaf–spine\/inter-switch links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"authoritative-certification-icon\" style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch4 data-end=\"5086\" data-start=\"5022\"\u003eWhy Choose NSComm MPO 16F to 2xMPO 8F APC OM4 Breakout Cables?\u003c\/h4\u003e\n\u003cul data-end=\"5885\" data-start=\"5088\"\u003e\n\u003cli data-end=\"5220\" data-start=\"5088\"\u003e\n\u003cp data-end=\"5220\" data-start=\"5090\"\u003e\u003cstrong data-end=\"5123\" data-start=\"5090\"\u003eDesigned for 400G\/800G fanout\u003c\/strong\u003e – Ideal for aggregating two 400G QSFP-DD\/OSFP multimode ports into a single 800G QSFP-DD link.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5360\" data-start=\"5221\"\u003e\n\u003cp data-end=\"5360\" data-start=\"5223\"\u003e\u003cstrong data-end=\"5258\" data-start=\"5223\"\u003eCrossover breakout architecture\u003c\/strong\u003e – Pre-engineered crossover polarity simplifies direct device-to-device parallel optics connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5503\" data-start=\"5361\"\u003e\n\u003cp data-end=\"5503\" data-start=\"5363\"\u003e\u003cstrong data-end=\"5407\" data-start=\"5363\"\u003eLower loss than cassette-based solutions\u003c\/strong\u003e – Direct breakout reduces mated interfaces, improving insertion loss and overall link margin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5635\" data-start=\"5504\"\u003e\n\u003cp data-end=\"5635\" data-start=\"5506\"\u003e\u003cstrong data-end=\"5530\" data-start=\"5506\"\u003e8° APC angled polish\u003c\/strong\u003e – High return-loss APC interface helps minimize back reflections and maintain clean multimode signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5763\" data-start=\"5636\"\u003e\n\u003cp data-end=\"5763\" data-start=\"5638\"\u003e\u003cstrong data-end=\"5678\" data-start=\"5638\"\u003eBend-insensitive OM4 multimode fiber\u003c\/strong\u003e – Ensures stable performance in tight pathways and dense patch field environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"5885\" data-start=\"5764\"\u003e\n\u003cp data-end=\"5885\" data-start=\"5766\"\u003e\u003cstrong data-end=\"5799\" data-start=\"5766\"\u003eRiser-rated OFNR construction\u003c\/strong\u003e – Suitable for structured cabling, in-rack routing, and data center riser pathways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-end=\"5912\" data-start=\"5892\"\u003eLength Options\u003c\/h4\u003e\n\u003cp data-end=\"6109\" data-start=\"5914\"\u003e\u003cstrong data-end=\"5943\" data-start=\"5914\"\u003eStandard stocked lengths:\u003c\/strong\u003e\u003cbr data-end=\"5946\" data-start=\"5943\"\u003eAvailable in common trunk and breakout lengths suited for typical 400G\/800G switch-to-switch and switch-to-transceiver fanout scenarios within and between racks.\u003c\/p\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"6306\" data-start=\"6111\"\u003e\u003cstrong data-end=\"6130\" data-start=\"6111\"\u003eCustom lengths:\u003c\/strong\u003e\u003cbr data-end=\"6133\" data-start=\"6130\"\u003eCustom trunk lengths, breakout leg lengths, labeling, and connector configurations are available on request to match your panel layouts, routing paths, and optics locations.\u003c\/p\u003e\n\u003ch3 class=\"authoritative-certification-icon\" style=\"text-align: left;\"\u003eMore Details\u003c\/h3\u003e\n\u003ch4 style=\"text-align: left;\" class=\"authoritative-certification-icon\"\u003eQuality Certifications\u003cb\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/3Y_Warranty_50x50.png?v=1753520941\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO9001-SFP_50x50.png?v=1753520941\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO14001-SFP_50x50.png?v=1753520941\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO27001-SFP_50x50.png?v=1753520941\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO45001-SFP_50x50.png?v=1753520941\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/CE-SFP_50x50.png?v=1753520941\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/Reach-SFP_50x50.png?v=1753520941\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/CB-SFP_50x50.png?v=1753520941\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/cURus-UL_50x50.png?v=1753520941\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/FCC-SFP_50x50.png?v=1753520941\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/UKCA-SFP_50x50.png?v=1753521101\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003eDo you have any question about the NSComm MPO 16F to 2xMPO 8F APC MM OM4 Breakout Cable?\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp class=\"authoritative-certification-icon\" style=\"text-align: left;\"\u003ePlease \u003ca href=\"#chatty-chat\"\u003eChat with us\u003c\/a\u003e now!\u003c\/p\u003e\n\u003cp class=\"authoritative-certification-icon\" style=\"text-align: left;\"\u003eor leave us an message on \u003ca href=\"mailto:sales@network-switch.com\"\u003esales@network-switch.com\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4 class=\"pb-4 mb-4\"\u003eWarranty\u003c\/h4\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6 pr-md-5\"\u003e\n\u003ci class=\"i1\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003e100% Low Price Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNetwork-switch.com provides high-quality products at low wholesale prices\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6\"\u003e\n\u003ci class=\"i2\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003e100% Quality Assurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll items are ORIGINAL and GENUINE only.\u003cbr\u003eItem conditions are \"New Sealed\". They are fully tested by Certified CCIE \/ HCIE \/ RCNP Engineers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6 pr-md-5\"\u003e\n\u003ci class=\"i4\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003eFree Technical Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOur FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6\"\u003e\n\u003ci class=\"i3\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003e100% Money Back Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can contact our customer service team to exchange or return any product that you bought from us.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"detaildl_3 col-12 col-md-6 pr-md-5\"\u003e\n\u003ci class=\"i\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003eStandard Warranty Policy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOriginal New Sealed Enterprise Hardware: 3 Years\u003cbr\u003eOriginal New Sealed Consumer Devices: 1 Year\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_3 col-12 col-md-6\"\u003e\n\u003ci class=\"i\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003eThe Support Contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Network-Switch \u0026 NS","offers":[{"title":"1m (3ft)","offer_id":48886060056832,"sku":"NS-MPO16B8F-2OM4-1","price":1753.7,"currency_code":"USD","in_stock":true},{"title":"2m (7ft)","offer_id":48886060089600,"sku":"NS-MPO16B8F-2OM4-2","price":1917.0,"currency_code":"USD","in_stock":true},{"title":"3m (10ft)","offer_id":48886060122368,"sku":"NS-MPO16B8F-2OM4-3","price":2081.72,"currency_code":"USD","in_stock":true},{"title":"5m (16ft)","offer_id":48886060155136,"sku":"NS-MPO16B8F-2OM4-4","price":2408.32,"currency_code":"USD","in_stock":true},{"title":"10m (33ft)","offer_id":48886060187904,"sku":"NS-MPO16B8F-2OM4-5","price":3214.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/MPO-16F-16F-Breakout-OM4.jpg?v=1782318732","url":"https:\/\/alotechparts.com\/es\/products\/nscomm-mpo-16f-apc-to-2xmpo-8f-apc-breakout-cables-8-fibers-multimode-om4-ofnr-crossover","provider":"Alo Tech Solutions","version":"1.0","type":"link"}