{"product_id":"fluke-62-max-infrared-thermometer-calibrated","title":"Fluke 62 MAX Infrared Thermometer Calibrated","description":"\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"586\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"169\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"417\"\u003eFluke 62 MAX Infrared Thermometer Calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"169\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"417\"\u003eConduct non-contact temperature measurements on a variety of equipment including transformers, motors, pumps, panels, breakers, compressors, ducts, steam lines, valves, and vents using this infrared thermometer. It includes a single laser and boasts a durable design capable of withstanding drops of up to 9.8 feet (3 meters).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"169\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"417\"\u003eFluke Infrared Thermometer Calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"169\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"417\"\u003eThermometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties] [specifications]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"475\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"text-align: center;\" width=\"475\" colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTemperature range\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"320\"\u003e(-30 °C to 500 °C)\u003cbr data-mce-fragment=\"1\"\u003e(-22 °F to 932 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy (Calibration geometry with ambient temperature 23 °C +\/- 2 °C)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"320\"\u003e± 1.5 °C or ± 1.5 % of reading, whichever is greater\u003cbr data-mce-fragment=\"1\"\u003e± 2.0 °C at -10 °C to 0 °C\u003cbr data-mce-fragment=\"1\"\u003e± 3.0 °C at -30 °C to -10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOptical resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"320\"\u003e10:1\u003cbr data-mce-fragment=\"1\"\u003e(calculated at 90 % energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eResponse time (95 %)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u0026lt; 500 ms (95 % of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSpectral response\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEmissivity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0.1 °C (0.2 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRepeatability (% of reading) \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"320\"\u003e± 0.8 % of reading or\u003cbr data-mce-fragment=\"1\"\u003e± 1 °C (whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAuto Capture\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e(-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eInternal memory\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e(-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eFlashlight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e(-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e1 AA alkaline battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eBattery life\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSize\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0 °C to 50 °C (32 °F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage temperature \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e(-20 °C to 60 °C) (-4 °F to 140 °F) (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"320\"\u003eNon- condensing @ ≤ 10 °C (50 °F)\u003cbr data-mce-fragment=\"1\"\u003e≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F)\u003cbr data-mce-fragment=\"1\"\u003e≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F)\u003cbr data-mce-fragment=\"1\"\u003e≤ 45 % RH @ 40 °C (104 °F) to 50 °C (122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDrop test\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eImplement standard\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eQ\/ASF01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications] [accesories] [\/accesories]\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eFluke 62 MAX Infrared Thermometer Calibrated\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe Fluke 62 MAX Infrared thermometer offers similar functionalities to the Fluke 62 MAX+ but is equipped with a single laser and a 10:1 distance-to-spot ratio. This device enables non-contact temperature measurements on various equipment such as transformers, motors, pumps, panels, breakers, compressors, ducts, steam lines, valves, and vents. Its compact size and user-friendly design make it convenient to operate. Additionally, the IP54 rating for dust and water resistance ensures reliable and consistent temperature readings in challenging industrial environments, regardless of weather conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eQuick Specs:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eProvides a 10:1 distance-to-spot ratio\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eHighly accurate infrared thermometer for measuring temperatures from -30 to 500\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eOffers single laser targeting for accurate and repeatable measurements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eFeatures IP54 rating against dust and moisture\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePlease see the related tabs for the FLUKE-62MAX datasheet and compatible accessories.                                                                          \u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":48957992534272,"sku":"FLUKE-62MAX-NEW","price":176.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/FLUKE-62MAX_1.webp?v=1783442455","url":"https:\/\/alotechparts.com\/es\/products\/fluke-62-max-infrared-thermometer-calibrated","provider":"Alo Tech Solutions","version":"1.0","type":"link"}