{"product_id":"004-0-0017-s8-alarm-5-co2-sensor","title":"004-0-0017 S8 Alarm 5% CO2 Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eS8 5% Alarm CO2 Sensor \u003c\/strong\u003e(004-0-0017) is designed to act like a safety switch for alarm applications where CO2 leak detection around tanks or cylinders of compressed CO2 gas is required. It comes with Automatic Background Calibration (ABC) turned on.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003c\/em\u003eThanks to a new optical path design, the S8 can accurately measure carbon dioxide levels up to 5%, yet it has less than a 30x20x10mm footprint and runs on only 30mA.\u003c\/p\u003e\n\u003cp\u003eThis sensor is designed for commercial applications. It provides simple communication via UART which lets you change the measurement period and control the ABC period in real time. Background and zero-gas calibrations are also implemented in a simple manner.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow Power, Small Footprint Design\u003c\/li\u003e\n\u003cli\u003eAutomatic Background Calibration\u003c\/li\u003e\n\u003cli\u003eIndustry-Standard UART Communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eS8 Alarm 0-5% CO2 Sensor\u003c\/strong\u003e (004-0-0017) - pinless design for integration into high-volume OEM products. \u003cstrong\u003eABC on.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Development Kit\u003c\/strong\u003e (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free \u003ca href=\"\/es\/pages\/downloads\" title=\"Gaslab software\"\u003eGasLab® software\u003c\/a\u003e to measure and graph carbon dioxide or use our \u003ca href=\"https:\/\/github.com\/co2meter-org\/ExampleCode\" title=\"Source code on Github\" rel=\"noopener\" target=\"_blank\"\u003elibrary of source code on Github\u003c\/a\u003e to build your own application or for OEM batch testing\/configuration. Order the sensor on this page, then \u003ca href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\" title=\"Gas Sensor Development Kit\"\u003eorder the Devkit here\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: #286adc;\" data-mce-style=\"color: #286adc;\"\u003e\u003cstrong\u003eWe recommend that all first time users purchase both this sensor and the CM-200 Development Kit for fastest and easiest results.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement\u003c\/strong\u003e: non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e: Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0-5% (0-50,000ppm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time\u003c\/strong\u003e: 90% at 2 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement\u003c\/strong\u003e: \u003cspan\u003e 0.5 Hz (every 2 seconds)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ± 200ppm ± 10% of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Output\u003c\/strong\u003e: analog\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: UART Modbus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy\u003c\/strong\u003e: \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval\u003c\/strong\u003e: no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics\u003c\/strong\u003e: complete function check on startup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 32.7 × 19.7 × 8 mm (LxWxH)  \u0026lt; 8 grams.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input\u003c\/strong\u003e: 4.5-5.25 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current\u003c\/strong\u003e: 300 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 300mA peak, 30mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\" title=\"Terms and Conditions\"\u003e CO2Meter Terms and Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1946.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1946.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca title=\"S8 5% Datasheet\" href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1946.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/PSH1946.pdf\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e S8 5% Datasheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_Datasheet_SE_0037_Revised8.pdf?v=1653445443\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual_Datasheet_SE_0037_Revised8.pdf?v=1653445443\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca title=\"S8 Manual\" href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP0113.pdf\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/PSP0113.pdf\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e S8 5% Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Modbus_SE_0119_Revised8.pdf?v=1653445891\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Modbus_SE_0119_Revised8.pdf?v=1653445891\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #ff2a00;\" title=\"Modbus Communication\" href=\"chrome-extension:\/\/efaidnbmnnnibpcajpcglclefindmkaj\/https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2067.pdf\" data-mce-style=\"color: #ff2a00;\" data-mce-href=\"chrome-extension:\/\/efaidnbmnnnibpcajpcglclefindmkaj\/https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2067.pdf\"\u003e \u003c\/a\u003e\u003ca style=\"color: #ff2a00;\" href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2067.pdf\" title=\"Modbus Communication\" data-mce-style=\"color: #ff2a00;\" data-mce-href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/Dev\/publicerat\/TDE2067.pdf\" target=\"_blank\"\u003eModbus Communication Manual (pdf)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_168_SE_0037_Raspberry_Pi_to_SenseAir_Revised8.pdf?v=1653445714\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_168_SE_0037_Raspberry_Pi_to_SenseAir_Revised8.pdf?v=1653445714\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documention\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Connecting to Raspberry Pi via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN168-S8-raspberry-pi-files.zip?v=1653445941\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN168-S8-raspberry-pi-files.zip?v=1653445941\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\" alt=\"\" data-mce-src=\"\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Raspberry Pi Sample Code (ZIP)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN162-LP8-sensor-arduino-modbus-uart.pdf?v=1653446032\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN162-LP8-sensor-arduino-modbus-uart.pdf?v=1653446032\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"CO2 Sensor Documentation\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Connecting to TI CC3200 WIFI via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/SenseairISO.pdf?v=1613679881\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Senseair ISO Certification\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\" data-mce-style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"CO2Meter Gas Sensor Development Kit\" href=\"https:\/\/www.co2meter.com\/products\/gas-sensor-development-kit\"\u003e\u003cstrong\u003eGas Sensor Development Kit\u003c\/strong\u003e (CM-200)\u003c\/a\u003e- designed to provide customers with an easy drop-in solution. Includes our free \u003ca href=\"https:\/\/www.co2meter.com\/pages\/downloads\" title=\"Gaslab data logging software\"\u003eGaslab data logging software\u003c\/a\u003e. Sensor sold separately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"Default Title","offer_id":49030523584768,"sku":"004-0-0017","price":79.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/004-0-0017ShopifyImage_3aae6bdc-3f7f-4008-b3fb-00c3bdab08a4.jpg?v=1784471325","url":"https:\/\/alotechparts.com\/es\/products\/004-0-0017-s8-alarm-5-co2-sensor","provider":"Alo Tech Solutions","version":"1.0","type":"link"}