{"product_id":"planet-igs-5225-8p2t4s-ip30-industrial-l2l4-8-port-1000t-8023at-poe-2-port-101","title":"Planet IGS-5225-8P2T4S IP30 Industrial L2+\/L4 8-Port 1000T 802.3at PoE+ 2-port 10\/1","description":"\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eAdvanced Manageable PoE Solution for Hardened Environment\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003ePLANET IGS-5225-8P2T4S PoE L2+Industrial Managed PoE+ Switch, featuring\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003e8 10\/100\/1000BASE-T 802.3at PoE+ ports\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003ewith each port powering up to 36 watts, two\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003e10\/100\/1000BASE-T ports\u003c\/strong\u003e\u003c\/b\u003e, two\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003e100\/1000 BASE-X SFP ports\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eand two\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003e100\/1000\/2500 BASE-X SFP ports\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003ein an IP30 rugged metal case, can be installed in any difficult environment. It provides user-friendly yet advanced\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eIPv6\/IPv4 management\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003einterfaces, abundant\u003cb\u003e\u003cstrong\u003eL2\/L4 switching functions\u003c\/strong\u003e\u003c\/b\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eLayer 3 static routing\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003ecapability, and advanced\u003cb\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eITU-G.8032 ERPS Ring\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003etechnology to improve the rapid self-recovery capability and PLANET\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eintelligent PoE\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003efunctions for controlling the PoE outdoor IP surveillance and wireless network applications. It is able to operate reliably, stably and quietly in the temperature range from\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003e-40 to 75 degrees C\u003c\/strong\u003e\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eITU-T G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003etechnology, Spanning Tree Protocol (802.1s MSTP), and\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eredundant power\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003einput system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a simple Ring network, the recovery time of data link can be as fast as 10ms.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eHigh Power PoE for Security and Public Service Applications\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eAs the whole system comes with a total\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003e240-watt\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003ePoE budget, the IGS-5225-8P2T4S is designed specifically to satisfy the growing demand of higher power consuming network PDs (powered devices) such as multi-channel (802.11n\/ac\/ax) wireless LAN access points, PTZ (pan, tilt, zoom) speed dome network cameras and other PoE network devices.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eIntelligent Alive Check for Powered Device\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S can be configured to monitor connected PD’s status in real time via ping action. Once the PD stops working and responding, the IGS-5225-8P2T4S will recycle the PoE port power and bring the PD back to work. It also greatly enhances the reliability in that the PoE port will reset the PD power, thus reducing administrator’s management burden.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003ePoE Schedule for Energy Savings\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eUnder the trend of energy saving worldwide and contributing to environmental protection on the Earth, the IGS-5225-8P2T4S can effectively control the power supply besides its capability of giving high watts power. The built-in\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003e“PoE schedule”\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003efunction helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eScheduled Power Recycling\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specified time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eSMTP\/SNMP Trap Event Alert\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eEffective Alarm Alert for Better Protection\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eDigital Input and Digital Output for External Alarm\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S supports Digital Input and Digital Output on its front panel. This external alarm enables users to use Digital Input to detect and log external device status (such as door intrusion detector), and send event alarm to the administrators. The Digital Output could be used to alarm the administrators if the IGS-5225-8P2T4S port shows link down, link up or power failure.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eConvenient and Smart ONVIF Devices with Detection Feature\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003ePLANET has developed an awesome feature -- ONVIF Support -- which is specifically designed for co-operating with video IP surveillances. From the IGS-5225-8P2T4S GUI, clients just need one click to search and show all of the ONVIF devices via network application. In addition, clients can upload floor images to the switch series making the deployments of surveillance and other devices easy for planning and inspection purposes. Moreover, clients can get real-time surveillance’s information and online\/offline status; the PoE reboot can be controlled from the GUI.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S can be programmed for advanced switch management functions such as dynamic port link aggregation, Q-in-Q VLAN, private VLAN, Rapid Spanning Tree Protocol, Layer 2 to Layer 4 QoS, bandwidth control and IGMP snooping. The IGS-5225-8P2T4S provides 802.1Q tagged VLAN, and the VLAN groups allowed will be maximally up to 4K. Via aggregation of supporting ports, the IGS-5225-8P2T4S allows the operation of a high-speed trunk combining multiple ports. It enables a maximum of up to 3 trunk groups with 6 ports per trunk group, and supports fail-over as well.  \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eNetwork with Cybersecurity Helps Minimize Security Risks\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S comes with enhanced cyber security to fend off cyber threats and cyber attacks. It supports SSHv2 and TLSv1.2 protocols to provide strong protection against advanced threats. Served as a key point to transmit data to customer's critical equipment in a business network, the cyber security feature of the IGS-5225-8P2T4S protects the switch management and enhances the security of the mission-critical network without any extra deployment cost and effort.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eEfficient Management\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eFor efficient management, the IGS-5225-8P2T4S is equipped with Command line, Web and SNMP management interfaces.\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eWith the built-in Web-based management interface, the IGS-5225-8P2T4S offers an easy-to-use, platform-independent management and configuration facility.\u003c\/li\u003e\n\u003cli\u003eFor text-based management, it can be accessed via Telnet and the console port.\u003c\/li\u003e\n\u003cli\u003eFor standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003ePowerful Security from Layer 2 to Layer 4\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S offers comprehensive Layer 2 to Layer 4\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eAccess Control List (ACL)\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003efor enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003e802.1x Port-based\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eMAC-based\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003euser and device authentication. With the\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eprivate VLAN\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003efunction, communication between edge ports can be prevented to ensure user privacy. \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eAdvanced IP Network Protection\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S also provides\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eDHCP Snooping\u003c\/strong\u003e\u003c\/b\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eIP Source Guard\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cb\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eDynamic ARP Inspection\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003efunctions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eWith the supported\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eprotocol, the IGS-5225-8P2T4S can easily integrate with\u003cb\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eSCADA\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003esystems,\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eHMI\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003esystems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s\u003cb\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eoperating information\u003c\/strong\u003e\u003c\/b\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003eport informatio\u003c\/strong\u003e\u003c\/b\u003en and\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003ecommunication status\u003c\/strong\u003e\u003c\/b\u003e, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003e1588 Time Protocol for Industrial Computing Networks\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eFlexibility and Extension Solution\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe two SFP ports built in the IGS-5225-8P2T4S support multi-speed,\u003cb\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e100BASE-FX\u003c\/strong\u003e\u003c\/b\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e\u003cstrong\u003e1000BASE-SX\/LX\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cb\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e2500BASE-X \u003c\/strong\u003e\u003c\/b\u003eSFP (Small Form-factor Pluggable) fiber-optic modules, meaning the administrator now can flexibly choose the suitable SFP transceiver according to not only the transmission distance but also the transmission speed required. \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe distance can be extended from 550 meters (multi-mode fiber) to 10\/50\/70\/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eIntelligent SFP Diagnosis Mechanism\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe IGS-5225-8P2T4S supports SFP-DDM (Digital Diagnostic Monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 10\/100\/1000BASE-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGigabit Ethernet RJ45 ports with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEEE 802.3at PoE+\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einjector function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 10\/100\/1000BASE-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGigabit Ethernet RJ45 ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 100\/1000BASE-X SFP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eports for SFP type auto detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 100\/1000\/2500BASE-X SFP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eports for SFP type auto detection\u003c\/li\u003e\n\u003cli\u003eOne RJ45 console interface for basic management and setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower over Ethernet \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with IEEE 802.3at Power over Ethernet Plus\/end-span PSE\u003c\/li\u003e\n\u003cli\u003eUp to 8 IEEE 802.3af\/802.3at devices powered\u003c\/li\u003e\n\u003cli\u003eSupports PoE power up to 36 watts for each PoE port\u003c\/li\u003e\n\u003cli\u003eAuto detects powered device (PD)\u003c\/li\u003e\n\u003cli\u003eCircuit protection prevents power interference between ports\u003c\/li\u003e\n\u003cli\u003eRemote power feeding up to 100m\u003c\/li\u003e\n\u003cli\u003ePoE management features\n\u003cul\u003e\n\u003cli\u003ePoE admin-mode control \u003c\/li\u003e\n\u003cli\u003ePoE management mode selection\u003c\/li\u003e\n\u003cli\u003ePoE legacy mode selection\u003c\/li\u003e\n\u003cli\u003ePoE budget setup option\u003c\/li\u003e\n\u003cli\u003ePer port PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE port power feeding priority\u003c\/li\u003e\n\u003cli\u003ePer PoE port power limit\u003c\/li\u003e\n\u003cli\u003ePoE port status monitoring\u003c\/li\u003e\n\u003cli\u003ePD classification detection\u003c\/li\u003e\n\u003cli\u003eSequence port PoE\u003c\/li\u003e\n\u003cli\u003ePoE extend mode control to support power feeding up to a distance of up to 160 meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntelligent PoE features\n\u003cul\u003e\n\u003cli\u003eTemperature threshold control\u003c\/li\u003e\n\u003cli\u003ePoE usage threshold control\u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003eLLDP PoE Neighbors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMod bus TCP for real-time monitoring in the SCADA system\u003c\/li\u003e\n\u003cli\u003eIEEE 1588v2 PTP (Precision Time Protocol) transparent clock mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eIndustrial Case and Installation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP30 aluminum case\u003c\/li\u003e\n\u003cli\u003eDIN-rail or wall-mount design\u003c\/li\u003e\n\u003cli\u003e48~56V DC, redundant power with reverse polarity protection\u003c\/li\u003e\n\u003cli\u003eSupports 6KV DC Ethernet ESD protection\u003c\/li\u003e\n\u003cli\u003e-40 to 75 degrees C operating temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDigital Input and Digital Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 digital input (DI)\u003c\/li\u003e\n\u003cli\u003e2 digital output (DO)\u003c\/li\u003e\n\u003cli\u003eIntegrate sensors into auto alarm system\u003c\/li\u003e\n\u003cli\u003eTransfer alarm to IP network via email and SNMP trap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLayer 3 IP Routing Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports maximum 32 static routes and route summarization\u003c\/li\u003e\n\u003cli\u003eRouting interface provides per VLAN routing mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLayer 2 Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStorm Control support\u003c\/li\u003e\n\u003cli\u003eBroadcast \/ Multicast \/ Unicast\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVLAN\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eSupports provider bridging (VLAN Q-in-Q, IEEE 802.1ad) \u003c\/li\u003e\n\u003cli\u003ePrivate VLAN Edge (PVE)\u003c\/li\u003e\n\u003cli\u003ePort Isolation\u003c\/li\u003e\n\u003cli\u003eMAC-based VLAN\u003c\/li\u003e\n\u003cli\u003eIP Subnet-based VLAN\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eVLAN Translation\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003eGVRP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eSpanning Tree Protocol\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Filtering\/BPDU Guard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLink Aggregation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003cli\u003eMaximum 6 trunk groups with 4 ports per trunk group\u003c\/li\u003e\n\u003cli\u003eUp to 8Gbps bandwidth (duplex mode) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProvide sport mirror (many-to-1)\u003c\/li\u003e\n\u003cli\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port\u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eSupports ERPS (Ethernet Ring Protection Switching)\u003c\/li\u003e\n\u003cli\u003eCompatible with Cisco\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUni-directional link detection\u003c\/strong\u003e(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP) \u003c\/li\u003e\n\u003cli\u003eIEEE 802.3ah OAM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQuality of Service\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIngress Shaper and Egress Rate Limit per port bandwidth control\u003c\/li\u003e\n\u003cli\u003e8 priority queues on all switch ports\u003c\/li\u003e\n\u003cli\u003eTraffic classification\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1p CoS\u003c\/li\u003e\n\u003cli\u003eIP TOS\/DSCP\/IP precedence\u003c\/li\u003e\n\u003cli\u003eIP TCP\/UDP port number\u003c\/li\u003e\n\u003cli\u003eTypical network application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003c\/li\u003e\n\u003cli\u003eSupports QoS and In\/Out bandwidth control on each port\u003c\/li\u003e\n\u003cli\u003eTraffic-policing on the switch port\u003c\/li\u003e\n\u003cli\u003eDSCP remarking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMulticast\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupportsIPv4 IGMP snooping v1, v2 and v3\u003c\/li\u003e\n\u003cli\u003eSupports IPv6 MLD snooping v1 and v2\u003c\/li\u003e\n\u003cli\u003eQuerier mode support\u003c\/li\u003e\n\u003cli\u003eIPv4 IGMP snooping port filtering\u003c\/li\u003e\n\u003cli\u003eIPv6 MLD snooping port filtering\u003c\/li\u003e\n\u003cli\u003eMVR (Multicast VLAN Registration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSecurity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuthentication\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1x port-based\/MAC-based network access authentication\u003c\/li\u003e\n\u003cli\u003eBuilt-in RADIUS client to co-operate with the RADIUS servers\u003c\/li\u003e\n\u003cli\u003eTACACS+ login users access authentication\u003c\/li\u003e\n\u003cli\u003eRADIUS \/ TACACS+ users access authentication\u003c\/li\u003e\n\u003cli\u003eGuest VLAN assigns clients to a restricted VLAN with limited services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess Control List\n\u003cul\u003e\n\u003cli\u003eIP-based Access Control List (ACL)\u003c\/li\u003e\n\u003cli\u003eMAC-based Access Control List\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSource MAC\/IP address binding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDHCP Snooping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto filter un-trusted DHCP messages\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic ARP Inspection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ediscards ARP packets with invalid MAC address to IP address binding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Source Guard\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprevents IP spoofing attacks\u003c\/li\u003e\n\u003cli\u003eIP address access management to prevent unauthorized intruder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 and IPv6 dual stack management\u003c\/li\u003e\n\u003cli\u003eSwitch Management Interfaces\n\u003cul\u003e\n\u003cli\u003eWeb switch management\u003c\/li\u003e\n\u003cli\u003eConsole and Telnet Command Line Interface \u003c\/li\u003e\n\u003cli\u003eSNMP v1 and v2c switch management\u003c\/li\u003e\n\u003cli\u003eSSHv2, TLSv1.2 and SNMPv3 secure access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSNMP Management\n\u003cul\u003e\n\u003cli\u003eFour RMON groups (history, statistics, alarms, and events) \u003c\/li\u003e\n\u003cli\u003eSNMP trap for interface Link Up and Link Down notification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPv6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP Address\/NTP\/DNS management\u003c\/li\u003e\n\u003cli\u003eBuilt-in Trivial File Transfer Protocol (TFTP) client\u003c\/li\u003e\n\u003cli\u003eBOOTP and DHCP for IP address assignment\u003c\/li\u003e\n\u003cli\u003eSystem Maintenance\n\u003cul\u003e\n\u003cli\u003eFirmware upload\/download via HTTP\u003c\/li\u003e\n\u003cli\u003eReset button for system reboot or reset to factory default\u003c\/li\u003e\n\u003cli\u003eDual Images\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDHCP Relay and DHCP Option82\u003c\/li\u003e\n\u003cli\u003eDHCP Server\u003c\/li\u003e\n\u003cli\u003eUser Privilege levels control\u003c\/li\u003e\n\u003cli\u003eNTP (Network Time Protocol)\u003c\/li\u003e\n\u003cli\u003eUPnP\u003c\/li\u003e\n\u003cli\u003eNetwork Diagnostic\n\u003cul\u003e\n\u003cli\u003eICMPv6\/ICMPv4 Remote Ping\u003c\/li\u003e\n\u003cli\u003eCable Diagnostic technology provides the mechanism to detect and report potential cabling issues\u003c\/li\u003e\n\u003cli\u003eSFP-DDM (Digital Diagnostic Monitor)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSMTP, Syslog and SNMP trap remote alarm\u003c\/li\u003e\n\u003cli\u003eLocal system Log\u003c\/li\u003e\n\u003cli\u003ePLANET NMS System and Smart Discovery Utility for deployment management\u003c\/li\u003e\n\u003cli\u003eProvides ONVIF for co-operating with PLANET video IP surveillances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"table table-sm table-bordered-bone table-striped-blue table-header-theme-blue table-header-no-border\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eHardware Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e10 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSFP Fiber Ports\u003c\/td\u003e\n\u003ctd\u003e2 100\/1000BASE-X SFP interfaces (Port-11 and Port-12)\u003cbr\u003e2 100\/1000\/2500BASE-X SFP interfaces (Port-13 and Port-14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Injector Ports\u003c\/td\u003e\n\u003ctd\u003e8 ports with 802.3at\/af PoE injector function with Port-1 to Port-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConsole\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45-to-RS232 serial port (115200, 8, N, 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e128MBytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e64MBytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003e6KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP30 aluminum case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDIN-rail kit and wall-mount kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRemovable 6-pin terminal block for power input\u003cbr\u003ePin 1\/2 for Power 1, Pin 3\/4 for fault alarm, Pin 5\/6 for Power 2\u003cbr\u003eRemovable 6-pin terminal block for DI\/DO interface\u003cbr\u003ePin 1\/2 for DI 1 \u0026amp; 2, Pin 3\/4 for DO 1 \u0026amp; 2, Pin 5\/6 for GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eOne relay output for power failure. Alarm relay current carry ability: 1A @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDigital Input\u003c\/td\u003e\n\u003ctd\u003e2 digital input (DI)\u003cbr\u003e　Level 0: -24V~2.1V (±0.1V)\u003cbr\u003e　Level 1: 2.1V~24V (±0.1V)\u003cbr\u003e　Input load to 24V DC, 10mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDigital Output\u003c\/td\u003e\n\u003ctd\u003e2 digital output(DO) Open collector to 24VDC, 100mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e76.8 x 107.3 x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eDual 48~56V DC (\u0026gt;51V DC for PoE+ output recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 7W\/23.88 BTU (Power on)\u003cbr\u003eMax. 262W\/893.98 BTU(Full Loading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLED Indicator\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eSystem:\u003c\/b\u003e\u003cbr\u003e　Power 1 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Power 2 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Fault Alarm (\u003cspan style=\"color: red;\"\u003e\u003cb\u003eRed\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Ring (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Ring Owner (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　DIDO (\u003cspan style=\"color: red;\"\u003e\u003cb\u003eRed\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePer 10\/100\/1000T RJ45 PoE+ Ports:\u003c\/b\u003e\u003cbr\u003e　PoE-in-Use (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　LNK\/ACT (Green)\u003cbr\u003e\u003cb\u003ePer 10\/100\/1000T RJ45 Ports:\u003c\/b\u003e\u003cbr\u003e　1000 LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　100 LNK\/ACT (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePer SFP Interface:\u003c\/b\u003e\u003cbr\u003e　100 LNK\/ACT (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　1G\/2.5G LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitching\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e34Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eThroughput (packet per second)\u003c\/td\u003e\n\u003ctd\u003e25.30Mpps@ 64 bytes packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAddress Table\u003c\/td\u003e\n\u003ctd\u003e8K entries, automatic source address learning and aging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e4Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3x pause frame for full duplex\u003cbr\u003eBack pressure for half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e9Kbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePower Over Ethernet\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3at Power over Ethernet Plus\/PSE\u003cbr\u003eBackward compatible with 802.3af Power over Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Supply Type\u003c\/td\u003e\n\u003ctd\u003eEnd-span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Output\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3af Standard\u003cbr\u003e　Per port 48V~51V DC (depending on the power supply), max. 15.4 watts\u003cbr\u003eIEEE 802.3at Standard\u003cbr\u003e　Per port 52V~56V DC (depending on the power supply), max. 36 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Pin Assignment\u003c\/td\u003e\n\u003ctd\u003e1\/2(+), 3\/6(-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003e48V Power input\u003cbr\u003e　125W maximum (depending on power input)\u003cbr\u003e52~56V Power input\u003cbr\u003e　240W maximum (depending on power input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMax. Number of Class 2 PDs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMax. Number of Class 3 PDs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMax. Number of Class 4 PDs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePoE Management Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eActive PoE device alive detection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Recycling\u003c\/td\u003e\n\u003ctd\u003eYes, daily or predeinded schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Schedule\u003c\/td\u003e\n\u003ctd\u003e4 schedule profiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Extend Mode\u003c\/td\u003e\n\u003ctd\u003eYes, max. 160 to 200 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE System Management\u003c\/td\u003e\n\u003ctd\u003eSystem PoE Admin control\u003cbr\u003eTotal PoE power budget control\u003cbr\u003ePoE Legacy mode\u003cbr\u003eOver-temperature threshold alarm\u003cbr\u003ePoE usage threshold alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Port Management\u003c\/td\u003e\n\u003ctd\u003ePort Enable\/Disable\/Schedule\u003cbr\u003ePort Priority\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 3Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIP Interfaces\u003c\/td\u003e\n\u003ctd\u003eMax. 8 VLAN interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Table\u003c\/td\u003e\n\u003ctd\u003eMax. 32 routing entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eIPv4 software static routing\u003cbr\u003eIPv6 software static routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 2 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003ePort disable\/enable\u003cbr\u003eAuto-negotiation 10\/100\/1000Mbps full and half duplex mode selection\u003cbr\u003eFlow control disable\/enable\u003cbr\u003ePower saving mode control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Status\u003c\/td\u003e\n\u003ctd\u003eDisplay each port’s speed duplex mode, link status, flow control status,\u003cbr\u003eauto negotiation status, trunk status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd\u003eTX \/ RX \/ Both\u003cbr\u003eMany-to-1 monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Q tag-based VLAN\u003cbr\u003eIEEE 802.1ad Q-in-Q tunneling\u003cbr\u003ePrivate VLAN Edge (PVE)\u003cbr\u003eMAC-based VLAN\u003cbr\u003eProtocol-based VLAN\u003cbr\u003eVLAN Translation\u003cbr\u003eVoice VLAN\u003cbr\u003eMVR (Multicast VLAN Registration)\u003cbr\u003eGVRP\u003cbr\u003eUp to 4k VLAN groups, out of 4094 VLAN IDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ad LACP\/static trunk\u003cbr\u003eSupports 6 trunk groups with 4 ports per trunk group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv4 IGMP (v1\/v2\/v3) snooping\u003cbr\u003eIPv4 IGMP querier mode support\u003cbr\u003eUp to 255 multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv6 MLD (v1\/v2) snooping\u003cbr\u003eIPv6 MLD querier mode support\u003cbr\u003eUp to 255 multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBandwidth Control\u003c\/td\u003e\n\u003ctd\u003ePer port bandwidth control\u003cbr\u003e　Ingress: 500Kb~1000Mbps\u003cbr\u003e　Egress: 500Kb~1000Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRING\u003c\/td\u003e\n\u003ctd\u003eSupports ERPS, and complies with ITU-T G.8032\u003cbr\u003eRecovery time \u0026lt; 10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 PTP(Precision Time Protocol)\u003cbr\u003e　Peer-to-peer transparent clock\u003cbr\u003e　End-to-end transparent clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eQoS\u003c\/td\u003e\n\u003ctd\u003eTraffic classification based, strict priority and WRR\u003cbr\u003e8-level priority for switching\u003cbr\u003e　Port number\u003cbr\u003e　802.1p priority\u003cbr\u003e　802.1Q VLAN tag\u003cbr\u003e　DSCP\/TOS field in IP packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSecurity Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAccess Control List\u003c\/td\u003e\n\u003ctd\u003eIP-based ACL\/MAC-based ACL\u003cbr\u003eACL based on:\u003cbr\u003e　MAC Address\u003cbr\u003e　IP Address\u003cbr\u003e　Ethertype\u003cbr\u003e　Protocol Type\u003cbr\u003e　VLAN ID\u003cbr\u003e　DSCP\u003cbr\u003e　802.1p Priority\u003cbr\u003eUp to 256 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003ePort Security\u003cbr\u003eIP source guard\u003cbr\u003eDynamic ARP inspection\u003cbr\u003eCommand line authority control based on user level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAAA\u003c\/td\u003e\n\u003ctd\u003eRADIUS client\u003cbr\u003eTACACS+ client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNetwork Access Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x port-based network access control\u003cbr\u003eMAC-based authentication\u003cbr\u003eLocal\/RADIUS authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitch Management\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eConsole;Telnet; Web browser; SNMP v1, v2c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eSSHv2, TLS v1.2, SNMPv3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSystem Management\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade by HTTP protocol through Ethernet network\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eRemote syslog\u003cbr\u003eSystem log\u003cbr\u003eLLDP protocol\u003cbr\u003eNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEvent Management\u003c\/td\u003e\n\u003ctd\u003eRemote syslog\u003cbr\u003eLocal system log\u003cbr\u003eSMTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eONVIF\u003c\/td\u003e\n\u003ctd\u003eONVIF device discovery\u003cbr\u003eONVIF device monitoring\u003cbr\u003eFloor Map\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC1213 MIB-II\u003cbr\u003eRFC 2863 IF-MIB\u003cbr\u003eRFC1493 Bridge MIB\u003cbr\u003eRFC1643 Ethernet MIB\u003cbr\u003eRFC2863 Interface MIB\u003cbr\u003eRFC2665 Ether-Like MIB\u003cbr\u003eRFC2737 Entity MIB\u003cbr\u003eRFC2819 RMON MIB (Groups 1, 2, 3 and 9)\u003cbr\u003eRFC2618 RADIUS Client MIB\u003cbr\u003eRFC3411SNMP-Frameworks-MIB\u003cbr\u003eIEEE802.1X PAE\u003cbr\u003eLLDP\u003cbr\u003eMAU-MIB\u003cbr\u003ePower over Ethernet MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandards Conformance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStability Testing\u003c\/td\u003e\n\u003ctd\u003eIEC60068-2-32 (free fall)\u003cbr\u003eIEC60068-2-27 (shock)\u003cbr\u003eIEC60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE802.3 10BASE-T\u003cbr\u003eIEEE802.3u 100BASE-TX\/100BASE-FX\u003cbr\u003eIEEE802.3z Gigabit SX\/LX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE802.3x flow control and back pressure\u003cbr\u003eIEEE802.3ad port trunk with LACP\u003cbr\u003eIEEE802.1D Spanning Tree Protocol\u003cbr\u003eIEEE802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE802.1p Class of Service\u003cbr\u003eIEEE802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1ad Q-in-Q VLAN stacking\u003cbr\u003eIEEE 802.1X Port Authentication Network Control\u003cbr\u003eIEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3af Power over Ethernet\u003cbr\u003eIEEE 802.3at Power over Ethernet Plus\u003cbr\u003eIEEE 802.3ah OAM\u003cbr\u003eIEEE 1588 PTPv2\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 793 TFTP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eRFC 3376 IGMP version 3\u003cbr\u003eRFC 2710 MLD version 1\u003cbr\u003eRFC 3810 MLD version 2\u003cbr\u003eITU-T G.8032 ERPS Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":48892940747008,"sku":"IGS-5225-8P2T4S","price":1047.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/box_IGS-5225-8P2T4S.jpg?v=1782490925","url":"https:\/\/alotechparts.com\/es-mx\/products\/planet-igs-5225-8p2t4s-ip30-industrial-l2l4-8-port-1000t-8023at-poe-2-port-101","provider":"Alo Tech Solutions","version":"1.0","type":"link"}