{"product_id":"planet-igs-5225-4p2s-ip40-industrial-l2l4-4-port-1000t-8023at-poe-2-port-100","title":"Planet IGS-5225-4P2S IP40 Industrial L2+\/L4 4-Port 1000T 802.3at PoE + 2-Port 100","description":"\u003cp\u003e\u003cstrong\u003eAdvanced Manageable PoE+ Solution for Hardened Environment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eComplying with the IEEE 802.3at Power over Ethernet Plus technology, PLANET’s improved IGS-5225-4P2S L2+ Industrial Managed PoE+ Switch features four 10\/100\/1000BASE-T 802.3at PoE+ ports with each port powering up to 36 watts, and\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003etwo 100\/1000\/2500BASE-X SFP interfaces\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein a rugged IP30 metal case for stable operation in heavy industrial environments. It supports rich PoE operation modes including 36-watt 802.3at type-2 PoE+ ports, 36-watt legacy mode and force mode to solve the incompatibility of non-standard 4-pair PoE PDs in the field. \u003c\/p\u003e\n\u003cp\u003eWith a total power budget of up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e144 watts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor different kinds of PoE applications, the IGS-5225-4P2S provides a quick, safe and cost-effective 802.3at PoE+ network solution for small businesses and enterprises.\u003c\/p\u003e\n\u003cp\u003eBeing able to operate under wide temperature range from -40 to 75 degrees C, the IGS-5225-4P2S can be placed in almost any difficult environment. The IGS-5225-4P2S also allows either DIN-rail or wall mounting for efficient use of cabinet space.\u003c\/p\u003e\n\u003cp\u003e \u003cimg class=\"img-fluid\" height=\"320\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/IGS-5225-4P2Sv2_6.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCybersecurity Network Solution to Minimize Security Risks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cybersecurity features that virtually need no effort and cost to have include the protection of the switch management and the enhanced security of the mission-critical network. Both SSHv2 and TLSv1.2 protocols are utilized to provide strong protection against advanced threats. The network administrator can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp\u003e \u003cimg class=\"img-fluid\" height=\"281\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/IGS-5225-4P2Sv2-1.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eITU-T G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etechnology, Spanning Tree Protocol (802.1s MSTP), and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einput system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments.\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S also protects customer’s industrial network connectivity with switching recovery capability that is used for implementing fault tolerant ring and mesh network architectures. If the Industrial network is interrupted accidentally, the fault recovery time could be as\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003efast\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10ms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto quickly bring the network back to normal operation.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"510\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_PoE-switch-ERPS_Redundant-Connection.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConvenient and Smart ONVIF Devices with Detection Feature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET has developed an awesome feature -- ONVIF Support -- which is specifically designed for cooperating with video IP surveillances. From the IGS-5225-4P2S’s GUI, you just need one click to search and show all of the ONVIF devices via network application. In addition, you can upload floor images to the switch and can remotely monitor or inspect an assembly line. Moreover, you can get real-time surveillance information and online\/offline status; the PoE reboot can be controlled from the GUI.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"378\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_ONVIF-for-PoE-switch_Industrial.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Unique PoE Functions for Powered Devices Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs it is the industrial managed PoE+ switch for surveillance, wireless and VoIP networks, the IGS-5225-4P2S features the following special PoE management functions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePD Alive Check\u003c\/li\u003e\n\u003cli\u003eScheduled Power Recycling \u003c\/li\u003e\n\u003cli\u003ePoE Schedule\u003c\/li\u003e\n\u003cli\u003ePoE Usage Monitoring\u003c\/li\u003e\n\u003cli\u003ePoE Extension\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Powered Device Alive Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S PoE+ Switch can be configured to monitor connected PD’s status in real time via ping action. Once the PD stops working and responding, the IGS-5225-4P2S will recycle the PoE port power and bring the PD back to work. It also greatly enhances the reliability in that the PoE port will reset the PD power, thus reducing administrator’s management burden.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"336\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_PD-Alive-Check.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScheduled Power Recycling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specified time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"337\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_Scheduled-Power-Recycling.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePoE Schedule for Energy Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnder the trend of energy savings worldwide and contributing to environmental protection on the Earth, the IGS-5225-4P2S can effectively control the power supply besides its capability of giving high watts power. The built-in “\u003cstrong\u003ePoE schedule\u003c\/strong\u003e” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"253\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_PoE-Schedule-for-Energy-Saving.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent LED Indicator for Real-time PoE Usage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S helps users to monitor the current status of PoE power usage easily and efficiently by means of its advanced LED indication. Called “\u003cstrong\u003ePoE Power Usage\u003c\/strong\u003e”, the front panel of the IGS-5225-4P2S has four amber LEDs indicating\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30W\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e60W\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e90W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e120W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof PoE power usage.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"355\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/IGS-5225-4P2Sv2-21.png\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePoE Usage Monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVia the power usage chart in the web management interface, the IGS-5225-4P2S enables the administrator to monitor the status of the power usage of the connected PDs in real time. Thus, it greatly enhances the management efficiency of the facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e802.3at PoE+ Power and Ethernet Data Transmission Distance Extension\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn the “\u003cstrong\u003eExtend\u003c\/strong\u003e” operation mode, the IGS-5225-4P2S operates on a per-port basis at 10Mbps duplex operation but can support 22-watt PoE power output over a distance of up to 250 meters overcoming the 100m limit on Ethernet UTP cable. With this brand-new feature, the IGS-5225-4P2S provides an additional solution for 802.3at\/af PoE distance extension, thus saving the cost of Ethernet cable installation. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"242\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_PoE-switch_Extend-Mode.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIPv6\/IPv4 Dual Stack Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupporting both IPv6 and IPv4 protocols, the IGS-5225-4P2S helps the SMBs to step in the IPv6 era with the lowest investment as its network facilities need not be replaced or overhauled if the IPv6 FTTx edge network is set up. \u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"388\" width=\"701\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_IPv6_IPv4-Dual-Stack-Management.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSMTP\/SNMP Trap Event Alert\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"427\" width=\"701\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_SMTP_SNMP-Trap-Event-Alert_2.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEffective Alarm Alert for Better Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource.\u003c\/p\u003e\n\u003cp\u003e \u003cimg class=\"img-fluid\" height=\"282\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/IGS-5225-4P2Sv2-3.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 IPv4 and IPv6 Software VLAN Routing for Secure and Flexible Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo help customers stay on top of their businesses, the IGS-5225-4P2S not only provides ultra high transmission performance and excellent Layer 2 technologies, but also IPv4\/IPv6 software VLAN routing feature which allows to cross over different VLANs and different IP addresses for the purpose of having a highly-secure, flexible management and simpler networking application.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S can be programmed for advanced switch management functions such as dynamic port link aggregation, Q-in-Q VLAN, private VLAN, Rapid Spanning Tree Protocol, Layer 2 to Layer 4 QoS, bandwidth control and IGMP snooping. The IGS-5225-4P2S provides 802.1Q tagged VLAN, and the VLAN groups allowed will be maximally up to 4K. Via aggregation of supporting ports, the IGS-5225-4P2S allows the operation of a high-speed trunk combining multiple ports. It enables a maximum of up to 3 trunk groups with 6 ports per trunk group, and supports fail-over as well. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"217\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_Robust-Layer-2-Features.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Secure Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor efficient management, the IGS-5225-4P2S is equipped with Command line, Web and SNMP management interfaces.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith the built-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWeb-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanagement interface, the IGS-5225-4P2S offers an easy-to-use, platform-independent management and configuration facility.\u003c\/li\u003e\n\u003cli\u003eFor\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003etext-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanagement, it can be accessed via Telnet and the RJ45 console port.\u003c\/li\u003e\n\u003cli\u003eBy supporting the standard SNMP protocol, the switch can be managed via any SNMP-based management software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"137\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_Secure-Management.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePowerful Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S offers comprehensive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLayer 2 to Layer 4 Access Control List (ACL)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e802.1x Port-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMAC-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euser and device authentication. With the\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eprivate VLAN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunction, communication between edge ports can be prevented to ensure user privacy. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote Management Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET's\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal Network Management System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(UNI-NMS) and NMSViewerPro\/CloudViewerPro app support IT staff by remotely managing all network devices and monitoring PDs' operational statuses. Thus, they're designed for both the enterprises and industries where deployments of PDs can be as remote as possible, without having to go to the actual location once a bug or faulty condition is found. With the UNI-NMS or NMSViewerPro\/CloudViewerPro app, all kinds of businesses can now be speedily and efficiently managed from one platform.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"376\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_CloudViewerPro-App.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexibility and Extension Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe additional two mini-GBIC slots built in the IGS-5225-4P2S support triple-speed 100\/1000\/2500BASE-X SFP (small form-factor pluggable) fiber-optic modules, meaning the administrator now can flexibly choose the suitable SFP transceiver according to not only the transmission distance but also the transmission speed required. The distance can be extended from 300 meters to 2km (multi-mode fiber) and to 10\/20\/30\/40\/60\/70\/80\/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent SFP Diagnosis Mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S supports SFP-\u003cstrong\u003eDDM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Digital Diagnostic Monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"350\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_Intelligent-SFP_SFP+-Diagnosis-Mechanism.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the supported\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eModbus TCP\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocol, the IGS-5225-4P2S can easily integrate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCADA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoperating information\u003c\/strong\u003e,\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eport information\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication status\u003c\/strong\u003e, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1588 Time Protocol for Industrial Computing Networks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-5225-4P2S is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"484\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49739\/Common_Time-Synchronization-in-Network.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 10\/100\/1000BASE-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGigabit Ethernet RJ45 ports with 802.3at PoE+ injector function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 100\/1000\/2500BASE-X SFP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eslots for SFP type auto detection\u003c\/li\u003e\n\u003cli\u003eOne RJ45 console interface for basic management and setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower over Ethernet \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with IEEE 802.3at Power over Ethernet Plus Type-2 PSE\u003c\/li\u003e\n\u003cli\u003eBackward compatible with IEEE 802.3af PD device\u003c\/li\u003e\n\u003cli\u003eUp to 4 ports of IEEE 802.3af\/IEEE 802.3at PoE+ devices powered\u003c\/li\u003e\n\u003cli\u003eSupports PoE power up to 36 watts for each PoE port\u003c\/li\u003e\n\u003cli\u003eTotal of 144-watt PoE budget\u003c\/li\u003e\n\u003cli\u003eAuto detects powered device (PD)\u003c\/li\u003e\n\u003cli\u003eCircuit protection prevents power interference between ports\u003c\/li\u003e\n\u003cli\u003eRemote power feeding up to 100m in standard mode and 250m in extend mode\u003c\/li\u003e\n\u003cli\u003ePoE management features\n\u003cul\u003e\n\u003cli\u003ePoE admin-mode control \u003c\/li\u003e\n\u003cli\u003ePoE management mode selection\u003c\/li\u003e\n\u003cli\u003ePer port PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE port power feeding priority\u003c\/li\u003e\n\u003cli\u003ePer PoE port power limit\u003c\/li\u003e\n\u003cli\u003ePoE Port Status monitoring\u003c\/li\u003e\n\u003cli\u003ePD classification detection\u003c\/li\u003e\n\u003cli\u003eSequence port PoE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntelligent PoE features\n\u003cul\u003e\n\u003cli\u003ePoE Legacy\/Force mode enable\/disable\u003c\/li\u003e\n\u003cli\u003eTemperature threshold control\u003c\/li\u003e\n\u003cli\u003ePoE usage threshold control\u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003eLLDP PoE Neighbors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Protocol\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModbus TCP for real-time monitoring in a SCADA system\u003c\/li\u003e\n\u003cli\u003eIEEE 1588v2 PTP (Precision Time Protocol) transparent clock mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Case and Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP30 metal case \u003c\/li\u003e\n\u003cli\u003eDIN-rail and wall-mount designs\u003c\/li\u003e\n\u003cli\u003eDC 48-54V, redundant power with reverse polarity protection\u003c\/li\u003e\n\u003cli\u003eSupports 6000V DC Ethernet ESD protection\u003c\/li\u003e\n\u003cli\u003e-40 to 75 degrees C operating temperature \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents packet loss with back pressure (half-duplex) and IEEE 802.3x pause frame flow control (full-duplex)\u003c\/li\u003e\n\u003cli\u003eHigh performance of Store-and-Forward architecture, and runt\/CRC filtering eliminates erroneous packets to optimize the network bandwidth\u003c\/li\u003e\n\u003cli\u003eStorm Control support\n\u003cul\u003e\n\u003cli\u003eBroadcast\/Multicast\/Unicast\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVLAN\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eSupports provider Bridging (VLAN Q-in-Q, IEEE 802.1ad) \u003c\/li\u003e\n\u003cli\u003ePrivate VLAN Edge (PVE)\u003c\/li\u003e\n\u003cli\u003ePort Isolation\u003c\/li\u003e\n\u003cli\u003eMAC-based VLAN\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003eVLAN Translation\u003c\/li\u003e\n\u003cli\u003eGVRP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpanning Tree Protocol\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Guard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLink Aggregation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003cli\u003eMaximum 3 trunk groups with 6 ports per trunk group \u003c\/li\u003e\n\u003cli\u003eUp to 18Gbps bandwidth (duplex mode) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProvides port mirror (many-to-1)\u003c\/li\u003e\n\u003cli\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port \u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eSupports ERPS (Ethernet Ring Protection Switching)\u003c\/li\u003e\n\u003cli\u003eCompatible with Cisco Uni-directional link detection(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP) and LLDP-MED\u003c\/li\u003e\n\u003cli\u003eProvides ONVIF for cooperating with PLANET video IP surveillances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 IP Routing Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports maximum 32 static routes and route summarization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuality of Service\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIngress Shaper and Egress Rate Limit per port bandwidth control\u003c\/li\u003e\n\u003cli\u003e8 priority queues on all switch ports\u003c\/li\u003e\n\u003cli\u003eTraffic classification\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1p CoS\u003c\/li\u003e\n\u003cli\u003eIP TOS\/DSCP\/IP precedence\u003c\/li\u003e\n\u003cli\u003eIP TCP\/UDP port number\u003c\/li\u003e\n\u003cli\u003eTypical network application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003c\/li\u003e\n\u003cli\u003eSupports QoS and In\/Out bandwidth control on each port\u003c\/li\u003e\n\u003cli\u003eTraffic-policing policies on the switch port\u003c\/li\u003e\n\u003cli\u003eDSCP remarking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulticast\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports IPv4 IGMP snooping v1, v2 and v3\u003c\/li\u003e\n\u003cli\u003eSupports IPv6 MLD snooping v1 and v2\u003c\/li\u003e\n\u003cli\u003eQuerier mode support\u003c\/li\u003e\n\u003cli\u003eIPv4 IGMP snooping port filtering\u003c\/li\u003e\n\u003cli\u003eIPv6 MLD snooping port filtering\u003c\/li\u003e\n\u003cli\u003eMulticast VLAN Registration (MVR) support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuthentication\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1x Port-based\/MAC-based network access authentication\u003c\/li\u003e\n\u003cli\u003eBuilt-in RADIUS client to co-operate with the RADIUS servers\u003c\/li\u003e\n\u003cli\u003eTACACS+ login users access authentication\u003c\/li\u003e\n\u003cli\u003eRADIUS\/TACACS+ users access authentication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess Control List\n\u003cul\u003e\n\u003cli\u003eIP-based Access Control List (ACL)\u003c\/li\u003e\n\u003cli\u003eMAC-based Access Control List\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSource MAC\/IP address binding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDHCP Snooping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto filter un-trusted DHCP messages\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic ARP Inspection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ediscards ARP packets with invalid MAC address to IP address binding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Source Guard\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprevents IP spoofing attacks\u003c\/li\u003e\n\u003cli\u003eIP address access management to prevent unauthorized intruder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 and IPv6 dual stack management\u003c\/li\u003e\n\u003cli\u003eSwitch Management Interfaces\n\u003cul\u003e\n\u003cli\u003eConsole\/Telnet Command Line Interface \u003c\/li\u003e\n\u003cli\u003eWeb switch management\u003c\/li\u003e\n\u003cli\u003eSNMP v1, v2c, and v3 switch management\u003c\/li\u003e\n\u003cli\u003eSSHv2 and TLSv1.2 secure access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPv6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP Address\/NTP\/DNS management\u003c\/li\u003e\n\u003cli\u003eBOOTP and DHCP for IP address assignment\u003c\/li\u003e\n\u003cli\u003eSystem Maintenance\n\u003cul\u003e\n\u003cli\u003eFirmware upload\/download via HTTP\u003c\/li\u003e\n\u003cli\u003eConfiguration upload\/download through HTTP\u003c\/li\u003e\n\u003cli\u003eReset button for system reboot or reset to factory default\u003c\/li\u003e\n\u003cli\u003eDual Images\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDHCP Relay\u003c\/li\u003e\n\u003cli\u003eDHCP Option82\u003c\/li\u003e\n\u003cli\u003eDHCP Server Mode support\u003c\/li\u003e\n\u003cli\u003eUser Privilege levels control\u003c\/li\u003e\n\u003cli\u003eNTP (Network Time Protocol)\u003c\/li\u003e\n\u003cli\u003eLink OAM\u003c\/li\u003e\n\u003cli\u003eNetwork Diagnostic\n\u003cul\u003e\n\u003cli\u003eICMPv6\/ICMPv4 Remote Ping\u003c\/li\u003e\n\u003cli\u003eCable Diagnostic technology provides the mechanism to detect and report potential cabling issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSMTP\/Syslog remote alarm\u003c\/li\u003e\n\u003cli\u003eFour RMON groups (history, statistics, alarms and events) \u003c\/li\u003e\n\u003cli\u003eSNMP trap for interface Link up and Link down notification\u003c\/li\u003e\n\u003cli\u003eSystem Log\u003c\/li\u003e\n\u003cli\u003eSFP-\u003cstrong\u003eDDM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Digital Diagnostic Monitor)\u003c\/li\u003e\n\u003cli\u003ePLANET Smart Discovery Utility for deployment management\u003c\/li\u003e\n\u003cli\u003ePLANET NMS system and NMSViewerPro\/CloudViewerPro for deployment management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"table table-sm table-bordered-bone table-striped-blue table-header-theme-blue table-header-no-border\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eHardware Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eVersion\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e4 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSFP Slots\u003c\/td\u003e\n\u003ctd\u003e2 100\/1000\/2500BASE-X mini-GBIC SFP ports (Port 5 and Port 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConsole\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45-to-RS232 serial port (115200, 8, N, 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP30 metal case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDIN-rail kit and wall-mount kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRemovable 6-pin terminal block for power input\u003cbr\u003ePin 1\/2 for Power 1, Pin 3\/4 for fault alarm, Pin 5\/6 for Power 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eOne relay output for power failure. Alarm Relay current carry ability: 1A @ DC 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e50 x 87x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e592g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e48-54V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e153 watts\/522BTU (Full loading with PoE function with DC 54V input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003e6KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEFT Protection\u003c\/td\u003e\n\u003ctd\u003e6KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLED Indicator\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eSystem:\u003c\/b\u003e\u003cbr\u003e　Power 1 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Power 2 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Fault Alarm (\u003cspan style=\"color: red;\"\u003e\u003cb\u003eRed\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Ring (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　R.O. (Ring Owner) (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePer 10\/100\/1000T RJ45 PoE+ Ports (Port 1 to port 4):\u003c\/b\u003e\u003cbr\u003e　PoE-in-use x 1 (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　LNK\/ACT x 1 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePer 100\/1000\/2500BASE-X SFP Interface (Port 5 to port 6):\u003c\/b\u003e\u003cbr\u003e　1G\/2.5G LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　100 LNK\/ACT (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003e4 x LED for PoE Usage:\u003c\/b\u003e\u003cbr\u003e　30W, 60W, 90W and 120W (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitching Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e18Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eThroughput (packet per second)\u003c\/td\u003e\n\u003ctd\u003e13.3Mpps@ 64Bytes packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAddress Table\u003c\/td\u003e\n\u003ctd\u003e8K entries, automatic source address learning and aging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e4Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3x pause frame for full duplex\u003cbr\u003eBack pressure for half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e9Kbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePower Over Ethernet\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3at Power over Ethernet Plus\/PSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Supply Type\u003c\/td\u003e\n\u003ctd\u003eEnd-span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Output\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3af Standard\u003cbr\u003e　Per port 48V~51V DC (depending on the power supply), max. 15.4 watts\u003cbr\u003eIEEE 802.3at Standard\u003cbr\u003e　Per port 51V~54V DC (depending on the power supply), max. 36 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Pin Assignment\u003c\/td\u003e\n\u003ctd\u003eEnd-span: 1\/2(+), 3\/6(-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003e144W maximum\u003cbr\u003e※Dual power input must be the same as DC voltage, like dual 54V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMax. Number of Class 2 PDs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMax. Number of Class 3 PDs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMax. Number of Class 4 PDs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePoE Management Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE System Management\u003c\/td\u003e\n\u003ctd\u003ePoE Port status monitoring\u003cbr\u003eTotal PoE power budget control\u003cbr\u003ePoE usage threshold and temperature threshold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnhanced PoE Mode\u003c\/td\u003e\n\u003ctd\u003eStandard\/Legacy\/Force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Device Live Detection\u003c\/td\u003e\n\u003ctd\u003ePer port remote PD IP address\u003cbr\u003e4 actions\u003cbr\u003e　None\u003cbr\u003e　PD reboot\u003cbr\u003e　PR reboot and alarm\u003cbr\u003e　Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Recycling\u003c\/td\u003e\n\u003ctd\u003eDaily or predefined schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Schedule\u003c\/td\u003e\n\u003ctd\u003e4 schedule profiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Extend Mode\u003c\/td\u003e\n\u003ctd\u003eRemote power feeding up to 100m in standard mode and 250m in extend mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 3 Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIP Interfaces\u003c\/td\u003e\n\u003ctd\u003eMax. 8 VLAN interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Table\u003c\/td\u003e\n\u003ctd\u003eMax. 32 routing entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eIPv4 software static routing\u003cbr\u003eIPv6 software static routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 2 Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003ePort disable\/enable\u003cbr\u003eAuto-negotiation 10\/100\/1000Mbps full and half duplex mode selection\u003cbr\u003eFlow control disable\/enable\u003cbr\u003ePort link capability control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Status\u003c\/td\u003e\n\u003ctd\u003eDisplay each port’s speed duplex mode, link status, flow control status,\u003cbr\u003eauto negotiation status, trunk status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd\u003eTX\/RX\/both\u003cbr\u003eMany-to-1 monitor\u003cbr\u003eRMirror – Remote Switched Port Analyzer (Cisco RSPAN)\u003cbr\u003eSupports up to 5 sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Q tag-based VLAN\u003cbr\u003eIEEE 802.1ad Q-in-Q tunneling\u003cbr\u003ePrivate VLAN Edge (PVE)\u003cbr\u003eMAC-based VLAN\u003cbr\u003eProtocol-based VLAN\u003cbr\u003eVoice VLAN\u003cbr\u003eMVR (Multicast VLAN Registration)\u003cbr\u003eGVRP (GARP VLAN Registration Protocol)\u003cbr\u003eUp to 4K VLAN groups, out of 4095 VLAN IDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eBPDU Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ad LACP\/static trunk\u003cbr\u003eSupports 3 trunk groups with 6 ports per trunk group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv4 IGMP (v1\/v2\/V3) snooping\u003cbr\u003eIPv4 IGMP querier mode support\u003cbr\u003eUp to 255 multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv6 MLD (v1\/v2) snooping\u003cbr\u003eIPv6 MLD querier mode support\u003cbr\u003eUp to 255 multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRing\u003c\/td\u003e\n\u003ctd\u003eSupports ERPS, and complies with ITU-T G.8032\u003cbr\u003eRecovery time \u0026lt; 10ms @ 3 nodes\u003cbr\u003eRecovery time \u0026lt;50ms @ 16 nodes\u003cbr\u003eSupports major ring and sub-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 PTP (Precision Time Protocol)\u003cbr\u003e　Peer-to-peer transparent clock\u003cbr\u003e　End-to-end transparent clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eQoS\u003c\/td\u003e\n\u003ctd\u003eTraffic classification based, strict priority and WRR\u003cbr\u003e8-level priority for switching\u003cbr\u003e　Port number\u003cbr\u003e　802.1p priority\u003cbr\u003e　802.1Q VLAN tag\u003cbr\u003e　DSCP\/TOS field in IP packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBandwidth Control\u003c\/td\u003e\n\u003ctd\u003ePer port bandwidth control\u003cbr\u003e　Ingress: 100Kb~3276Mbps\u003cbr\u003e　Egress: 100Kb~3281Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStorm Control\u003c\/td\u003e\n\u003ctd\u003eUnicast\/Multicast\/Broadcast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSecurity Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAccess Control List\u003c\/td\u003e\n\u003ctd\u003eIP-based ACL\/MAC-based ACL\u003cbr\u003eACL based on:\u003cbr\u003e　MAC Address\u003cbr\u003e　IP Address\u003cbr\u003e　Ethertype\u003cbr\u003e　Protocol Type\u003cbr\u003e　VLAN ID\u003cbr\u003e　DSCP\u003cbr\u003e　802.1p Priority\u003cbr\u003eUp to 512 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003ePort security\u003cbr\u003eIP source guard, up to 512 entries\u003cbr\u003eDynamic ARP inspection, up to 1K entries\u003cbr\u003eCommand line authority control based on user level\u003cbr\u003eStatic MAC address, up to 64 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAAA\u003c\/td\u003e\n\u003ctd\u003eRADIUS client\u003cbr\u003eTACACS+ client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNetwork Access Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x port-based network access control\u003cbr\u003eMAC-based authentication\u003cbr\u003eLocal\/RADIUS authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eManagement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eConsole; Telnet; Web browser; SNMP v1, v2c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eSSHv2,TLSv1.2, SNMP v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSystem Management\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade by HTTP protocol through Ethernet network\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eRemote syslog\u003cbr\u003eSystem log\u003cbr\u003eLLDP protocol\u003cbr\u003eNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003cbr\u003ePLANET NMS system\u003cbr\u003ePLANET NMSViewerPro\/CloudViewerPro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEvent Management\u003c\/td\u003e\n\u003ctd\u003eRemote syslog\u003cbr\u003eSystem log\u003cbr\u003eSMTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eONVIF\u003c\/td\u003e\n\u003ctd\u003eONVIF device discovery\u003cbr\u003eONVIF device monitoring\u003cbr\u003eFloor Map\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC-1213 MIB-II\u003cbr\u003eIF-MIB\u003cbr\u003eRFC-1493 Bridge MIB\u003cbr\u003eRFC-1643 Ethernet MIB\u003cbr\u003eRFC-2863 Interface MIB\u003cbr\u003eRFC-2665 Ether-Like MIB\u003cbr\u003eRFC-2819 RMON MIB (Group 1, 2, 3 and 9)\u003cbr\u003eRFC-2737 Entity MIB\u003cbr\u003eRFC-2618 RADIUS Client MIB\u003cbr\u003eRFC-2933 IGMP-STD-MIB\u003cbr\u003eRFC 3411 SNMP-Frameworks-MIB\u003cbr\u003eIEEE 802.1X PAE\u003cbr\u003eLLDP\u003cbr\u003eMAU-MIB\u003cbr\u003ePower over Ethernet MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandards Conformance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStability Testing\u003c\/td\u003e\n\u003ctd\u003eIEC60068-2-32 (free fall)\u003cbr\u003eIEC60068-2-27 (shock)\u003cbr\u003eIEC60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 10BASE-T\u003cbr\u003eIEEE 802.3u 100BASE-TX\/100BASE-FX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE 802.3z Gigabit SX\/LX\u003cbr\u003eIEEE 802.3bz 2.5GBASE-X\u003cbr\u003eIEEE 802.3x flow control and back pressure\u003cbr\u003eIEEE 802.3ad port trunk with LACP\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE 802.1p Class of Service\u003cbr\u003eIEEE 802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1ad Q-in-Q VLAN stacking\u003cbr\u003eIEEE 802.1x Port Authentication Network Control\u003cbr\u003eIEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3af Power over Ethernet\u003cbr\u003eIEEE 802.3at Power over Ethernet Plus\u003cbr\u003eIEEE 802.3ah OAM\u003cbr\u003eIEEE 802.1ag Connectivity Fault Management(CFM)\u003cbr\u003eIEEE 1588 PTPv2\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 783 TFTP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 793 TCP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eITU-T G.8032 ERPS Ring\u003cbr\u003eITU-T Y.1731 Performance Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":48892941041920,"sku":"IGS-5225-4P2S","price":609.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/box_IGS-5225-4P2Sv2.jpg?v=1782490927","url":"https:\/\/alotechparts.com\/es-mx\/products\/planet-igs-5225-4p2s-ip40-industrial-l2l4-4-port-1000t-8023at-poe-2-port-100","provider":"Alo Tech Solutions","version":"1.0","type":"link"}