{"product_id":"sk-hynix-768tb-nvme-u3-pcie-gen-40-x4-ri-sff-25-15mm-ssd-pe8110-series-for-cisco-ucs-c-series-server","title":"SK Hynix 7.68TB NVMe U.3 PCIe Gen 4.0 x4 RI SFF 2.5\" 15mm SSD Serie PE8110 para servidores Cisco UCS Serie C","description":"\u003cp data-end=\"109\" data-start=\"0\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"109\" data-start=\"0\"\u003eSK Hynix 7.68TB NVMe U.3 PCIe Gen 4.0 x4 RI SFF 2.5\" 15mm SSD para servidor Cisco UCS C-Series PE8110 Series\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003chr data-end=\"114\" data-start=\"111\"\u003e\n\u003ch3 data-end=\"142\" data-section-id=\"1441prs\" data-start=\"116\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"142\" data-start=\"120\"\u003eNota de compatibilidad\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"424\" data-start=\"143\" style=\"text-align: justify;\"\u003eEl SSD NVMe U.3 de la serie SK Hynix PE8110 es compatible con los servidores en rack Cisco UCS C-Series que admiten almacenamiento NVMe U.2\/U.3. Su funcionamiento completo requiere un backplane habilitado para NVMe y una bandeja de unidad SFF de 2,5\" compatible con Cisco, ya que no se admiten los soportes estándar de otros proveedores.\u003c\/p\u003e\n\n\u003chr data-end=\"429\" data-start=\"426\"\u003e\n\u003ch3 data-end=\"458\" data-section-id=\"120vc1f\" data-start=\"431\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"458\" data-start=\"435\"\u003eEspecificaciones principales\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"956\" data-start=\"459\"\u003e\n\n\t\u003cli data-end=\"483\" data-section-id=\"rgk8h3\" data-start=\"459\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"474\" data-start=\"461\"\u003eCapacidad:\u003c\/strong\u003e 7.68TB\u003c\/li\u003e\n\n\t\u003cli data-end=\"526\" data-section-id=\"11rtiau\" data-start=\"484\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"500\" data-start=\"486\"\u003eInterfaz:\u003c\/strong\u003e PCIe Gen4 x4 (NVMe 1.4)\u003c\/li\u003e\n\n\t\u003cli data-end=\"563\" data-section-id=\"1h9xqms\" data-start=\"527\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"545\" data-start=\"529\"\u003eFactor de forma:\u003c\/strong\u003e 2.5\" SFF (15mm)\u003c\/li\u003e\n\n\t\u003cli data-end=\"617\" data-section-id=\"1n8ex1a\" data-start=\"564\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"580\" data-start=\"566\"\u003eConector:\u003c\/strong\u003e U.3 (retrocompatible con U.2)\u003c\/li\u003e\n\n\t\u003cli data-end=\"649\" data-section-id=\"sldt2a\" data-start=\"618\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"631\" data-start=\"620\"\u003eSerie:\u003c\/strong\u003e SK Hynix PE8110\u003c\/li\u003e\n\n\t\u003cli data-end=\"698\" data-section-id=\"1whxrts\" data-start=\"650\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"667\" data-start=\"652\"\u003eControlador:\u003c\/strong\u003e SK Hynix Aquarius (ACNT036M)\u003c\/li\u003e\n\n\t\u003cli data-end=\"746\" data-section-id=\"1mog342\" data-start=\"699\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"715\" data-start=\"701\"\u003eTipo de NAND:\u003c\/strong\u003e TLC 3D de 128 capas (\"4D NAND\")\u003c\/li\u003e\n\n\t\u003cli data-end=\"789\" data-section-id=\"12otf6c\" data-start=\"747\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"767\" data-start=\"749\"\u003eTipo de carga de trabajo:\u003c\/strong\u003e Lectura intensiva (RI)\u003c\/li\u003e\n\n\t\u003cli data-end=\"817\" data-section-id=\"34wm9n\" data-start=\"790\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"806\" data-start=\"792\"\u003eResistencia:\u003c\/strong\u003e 1.0 DWPD\u003c\/li\u003e\n\n\t\u003cli data-end=\"855\" data-section-id=\"c72l9r\" data-start=\"818\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"829\" data-start=\"820\"\u003eMTBF:\u003c\/strong\u003e ~2.5–3.35 millones de horas\u003c\/li\u003e\n\n\t\u003cli data-end=\"907\" data-section-id=\"c87zdq\" data-start=\"856\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"880\" data-start=\"858\"\u003eConsumo de energía:\u003c\/strong\u003e ~10W activo \/ ~5–6W inactivo\u003c\/li\u003e\n\n\t\u003cli data-end=\"956\" data-section-id=\"1locfni\" data-start=\"908\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"923\" data-start=\"910\"\u003eSeguridad:\u003c\/strong\u003e Firmware firmado digitalmente (DS)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"961\" data-start=\"958\"\u003e\n\u003ch3 data-end=\"982\" data-section-id=\"1lfaz9a\" data-start=\"963\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"982\" data-start=\"967\"\u003eRendimiento\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1162\" data-start=\"983\"\u003e\n\n\t\u003cli data-end=\"1024\" data-section-id=\"1m4kca4\" data-start=\"983\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"1005\" data-start=\"985\"\u003eLectura secuencial:\u003c\/strong\u003e hasta 6.200 MB\/s\u003c\/li\u003e\n\n\t\u003cli data-end=\"1067\" data-section-id=\"1yoq0x7\" data-start=\"1025\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"1048\" data-start=\"1027\"\u003eEscritura secuencial:\u003c\/strong\u003e hasta 3.870 MB\/s\u003c\/li\u003e\n\n\t\u003cli data-end=\"1115\" data-section-id=\"2y0lnu\" data-start=\"1068\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"1091\" data-start=\"1070\"\u003eLectura aleatoria (4K):\u003c\/strong\u003e ~190.000–582.000 IOPS\u003c\/li\u003e\n\n\t\u003cli data-end=\"1162\" data-section-id=\"5u2xwr\" data-start=\"1116\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"1140\" data-start=\"1118\"\u003eEscritura aleatoria (4K):\u003c\/strong\u003e hasta ~190.000 IOPS\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1167\" data-start=\"1164\"\u003e\n\u003ch3 data-end=\"1216\" data-section-id=\"1ai2q08\" data-start=\"1169\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1216\" data-start=\"1173\"\u003eCompatibilidad con servidores Cisco UCS C-Series\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"1340\" data-start=\"1218\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1280\" data-start=\"1218\"\u003eGeneraciones M7 \/ M8 (PCIe Gen4 \/ Gen5 – Rendimiento completo):\u003c\/strong\u003e\u003cbr data-end=\"1283\" data-start=\"1280\"\u003e\nC220 M7, C240 M7, C225 M7, C245 M7, C240 M8SX, C240 M8L\u003c\/p\u003e\n\n\u003cp data-end=\"1428\" data-start=\"1342\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1389\" data-start=\"1342\"\u003eGeneración M6 (PCIe Gen4 – Soporte nativo):\u003c\/strong\u003e\u003cbr data-end=\"1392\" data-start=\"1389\"\u003e\nC220 M6, C240 M6, C225 M6, C245 M6\u003c\/p\u003e\n\n\u003cp data-end=\"1512\" data-start=\"1430\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1482\" data-start=\"1430\"\u003eGeneración M5 (PCIe Gen3 – Rendimiento reducido):\u003c\/strong\u003e\u003cbr data-end=\"1485\" data-start=\"1482\"\u003e\nC220 M5, C240 M5, C480 M5\u003c\/p\u003e\n\n\u003chr data-end=\"1517\" data-start=\"1514\"\u003e\n\u003ch3 data-end=\"1553\" data-section-id=\"i4kj3u\" data-start=\"1519\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1553\" data-start=\"1523\"\u003eNotas importantes de implementación\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2314\" data-start=\"1555\"\u003e\n\n\t\u003cli data-end=\"1683\" data-section-id=\"7xt1ec\" data-start=\"1555\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"1584\" data-start=\"1557\"\u003eRequisito de bandeja de unidad:\u003c\/strong\u003e\u003cbr data-end=\"1587\" data-start=\"1584\"\u003e\n\tDebe instalarse en una bandeja de unidad SFF de 2,5\" de Cisco compatible con la generación de chasis UCS.\u003c\/li\u003e\n\n\t\u003cli data-end=\"1818\" data-section-id=\"xdxw10\" data-start=\"1685\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"1713\" data-start=\"1687\"\u003eRequisito de backplane:\u003c\/strong\u003e\u003cbr data-end=\"1716\" data-start=\"1713\"\u003e\n\tSe requiere un backplane Cisco UCS habilitado para NVMe. Los backplanes solo SAS\/SATA no detectarán esta unidad.\u003c\/li\u003e\n\n\t\u003cli data-end=\"1973\" data-section-id=\"1dhu69a\" data-start=\"1820\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"1850\" data-start=\"1822\"\u003eCompatibilidad de interfaz:\u003c\/strong\u003e\u003cbr data-end=\"1853\" data-start=\"1850\"\u003e\n\tU.3 es retrocompatible con U.2, pero la funcionalidad completa de NVMe depende de la configuración del backplane y del riser de Cisco.\u003c\/li\u003e\n\n\t\u003cli data-end=\"2134\" data-section-id=\"1wph6y0\" data-start=\"1975\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"2001\" data-start=\"1977\"\u003eEscalado de rendimiento:\u003c\/strong\u003e\n\t\u003cul data-end=\"2134\" data-start=\"2006\"\u003e\n\n\t\t\u003cli data-end=\"2043\" data-section-id=\"17ret32\" data-start=\"2006\"\u003eM7\/M8: Rendimiento completo PCIe Gen4\u003c\/li\u003e\n\n\t\t\u003cli data-end=\"2080\" data-section-id=\"1det005\" data-start=\"2046\"\u003eM6: Rendimiento completo PCIe Gen4\u003c\/li\u003e\n\n\t\t\u003cli data-end=\"2134\" data-section-id=\"13s5uq3\" data-start=\"2083\"\u003eM5: Limitado a velocidades PCIe Gen3 (~3.5 GB\/s máx.)\u003c\/li\u003e\n\n\t\u003c\/ul\u003e\n\n\t\u003c\/li\u003e\n\n\t\u003cli data-end=\"2314\" data-section-id=\"1hgmn6k\" data-start=\"2136\" style=\"text-align: justify;\"\u003e\n\n\u003cstrong data-end=\"2162\" data-start=\"2138\"\u003eComportamiento de la gestión:\u003c\/strong\u003e\u003cbr data-end=\"2165\" data-start=\"2162\"\u003e\n\tCisco Intersight o CIMC pueden marcar la unidad como \"no-Cisco\" o \"no compatible\", pero normalmente funciona con normalidad cuando NVMe está configurado correctamente.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2319\" data-start=\"2316\"\u003e\n\u003ch3 data-end=\"2336\" data-section-id=\"3l32ru\" data-start=\"2321\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2336\" data-start=\"2325\"\u003eResumen\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"2539\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"2337\" style=\"text-align: justify;\"\u003eSSD NVMe U.3 empresarial de 7.68TB optimizado para cargas de trabajo de lectura intensiva, totalmente compatible con servidores Cisco UCS C-Series M5–M8 equipados con backplanes NVMe, con escalado de rendimiento según la generación.\u003c\/p\u003e\n","brand":"Hynix","offers":[{"title":"Default Title","offer_id":48889705332992,"sku":"P55173-004-CISCO-KIT","price":3912.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ca73cb99-ffda-5f73-b3d7-f30fdf3d9106.png?v=1782417245","url":"https:\/\/alotechparts.com\/es-br\/products\/sk-hynix-768tb-nvme-u3-pcie-gen-40-x4-ri-sff-25-15mm-ssd-pe8110-series-for-cisco-ucs-c-series-server","provider":"Alo Tech Solutions","version":"1.0","type":"link"}