{"product_id":"intel-1536tb-nvme-u2-pcie-gen30-x4-ri-sff-25-ssd-d5-p4326-ssdpe2nv153t8-for-dell-poweredge-server-with-dell-tray-gen-16th-15th-14th","title":"SSD D5-P4326 SSDPE2NV153T8 NVMe U.2 PCIe Gen3.0 x4 RI SFF 2.5\" de 15.36TB de Intel para servidor Dell PowerEdge con bandeja Dell de 16.ª\/15.ª\/14.ª generación","description":"\u003ch2 data-end=\"184\" data-section-id=\"g40014\" data-start=\"0\"\u003e\u003cstrong data-end=\"184\" data-start=\"3\"\u003eIntel 15.36TB NVMe U.2 PCIe Gen3.0 x4 de lectura intensiva (RI) SFF 2.5\" Unidad de estado sólido (SSD) D5-P4326 SSDPE2NV153T8 para servidor Dell PowerEdge con bandeja Dell Gen 16ª \/ 15ª \/ 14ª\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cblockquote data-end=\"432\" data-start=\"186\"\u003e\n\n\u003cp data-end=\"432\" data-start=\"188\"\u003e\u003cstrong data-end=\"227\" data-start=\"188\"\u003eNota importante (lea primero):\u003c\/strong\u003e\u003cbr data-end=\"230\" data-start=\"227\"\u003e\nEsta publicación incluye el \u003cstrong data-end=\"279\" data-start=\"256\"\u003eIntel SSDPE2NV153T8\u003c\/strong\u003e instalado en una \u003cstrong data-end=\"332\" data-start=\"295\"\u003ebandeja Dell 0DXD9H (DXD9H) 2.5\" SFF\u003c\/strong\u003e.\u003cbr data-end=\"336\" data-start=\"333\"\u003e\n\u003cstrong data-end=\"377\" data-start=\"336\"\u003eSe REQUIERE un backplane compatible con NVMe\u003c\/strong\u003e — los sistemas solo SAS\/SATA NO reconocerán esta unidad.\u003c\/p\u003e\n\n\n\u003c\/blockquote\u003e\n\n\u003chr data-end=\"437\" data-start=\"434\"\u003e\n\u003ch3 data-end=\"467\" data-section-id=\"5cy232\" data-start=\"439\"\u003e\u003cstrong data-end=\"467\" data-start=\"443\"\u003eNúmeros de pieza relacionados\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"546\" data-start=\"468\"\u003eSSDPE2NV153T8, SSDPE2NV153T801, J67810-075, 73-0004-01\u003cbr data-end=\"525\" data-start=\"522\"\u003e\nBandeja: 0DXD9H, DXD9H\u003c\/p\u003e\n\n\u003chr data-end=\"551\" data-start=\"548\"\u003e\n\u003ch3 data-end=\"569\" data-section-id=\"10rmw79\" data-start=\"553\"\u003e\u003cstrong data-end=\"569\" data-start=\"557\"\u003eDescripción general\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"887\" data-start=\"570\"\u003eEl \u003cstrong data-end=\"647\" data-start=\"574\"\u003eIntel D5-P4326 Series (SSDPE2NV153T8)\u003c\/strong\u003e es un \u003cstrong data-end=\"698\" data-start=\"667\"\u003eSSD NVMe empresarial de 15.36TB\u003c\/strong\u003e de alta capacidad optimizado para \u003cstrong data-end=\"741\" data-start=\"713\"\u003ecargas de trabajo intensivas en lectura\u003c\/strong\u003e. Combinado con el \u003cstrong data-end=\"790\" data-start=\"759\"\u003eDell DXD9H 2.5\" SFF carrier\u003c\/strong\u003e, está diseñado para una implementación sin problemas en servidores \u003cstrong data-end=\"852\" data-start=\"834\"\u003eDell PowerEdge\u003c\/strong\u003e que admiten almacenamiento NVMe.\u003c\/p\u003e\n\n\u003chr data-end=\"892\" data-start=\"889\"\u003e\n\u003ch3 data-end=\"931\" data-section-id=\"1niyif4\" data-start=\"894\"\u003e\u003cstrong data-end=\"931\" data-start=\"898\"\u003eEspecificaciones técnicas principales\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1126\" data-start=\"932\"\u003e\n\n\t\u003cli data-end=\"957\" data-section-id=\"1cxgu2n\" data-start=\"932\"\u003e\n\n\u003cstrong data-end=\"947\" data-start=\"934\"\u003eCapacidad:\u003c\/strong\u003e 15.36TB\u003c\/li\u003e\n\n\t\u003cli data-end=\"996\" data-section-id=\"tryml1\" data-start=\"958\"\u003e\n\n\u003cstrong data-end=\"974\" data-start=\"960\"\u003eInterfaz:\u003c\/strong\u003e PCIe Gen3.0 x4 NVMe\u003c\/li\u003e\n\n\t\u003cli data-end=\"1043\" data-section-id=\"zsmbw8\" data-start=\"997\"\u003e\n\n\u003cstrong data-end=\"1015\" data-start=\"999\"\u003eFactor de forma:\u003c\/strong\u003e 2.5\" U.2 (SFF-8639), 15mm\u003c\/li\u003e\n\n\t\u003cli data-end=\"1083\" data-section-id=\"1rscrsf\" data-start=\"1044\"\u003e\n\n\u003cstrong data-end=\"1060\" data-start=\"1046\"\u003eTipo de NAND:\u003c\/strong\u003e QLC 3D NAND de 64 capas\u003c\/li\u003e\n\n\t\u003cli data-end=\"1126\" data-section-id=\"12otf6c\" data-start=\"1084\"\u003e\n\n\u003cstrong data-end=\"1104\" data-start=\"1086\"\u003eTipo de carga de trabajo:\u003c\/strong\u003e Lectura intensiva (RI)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1131\" data-start=\"1128\"\u003e\n\u003ch3 data-end=\"1152\" data-section-id=\"1lfaz9a\" data-start=\"1133\"\u003e\u003cstrong data-end=\"1152\" data-start=\"1137\"\u003eRendimiento\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1322\" data-start=\"1153\"\u003e\n\n\t\u003cli data-end=\"1194\" data-section-id=\"1799ekp\" data-start=\"1153\"\u003e\n\n\u003cstrong data-end=\"1175\" data-start=\"1155\"\u003eLectura secuencial:\u003c\/strong\u003e Hasta 3,200 MB\/s\u003c\/li\u003e\n\n\t\u003cli data-end=\"1237\" data-section-id=\"1n1n140\" data-start=\"1195\"\u003e\n\n\u003cstrong data-end=\"1218\" data-start=\"1197\"\u003eEscritura secuencial:\u003c\/strong\u003e Hasta 1,600 MB\/s\u003c\/li\u003e\n\n\t\u003cli data-end=\"1282\" data-section-id=\"jtqfbz\" data-start=\"1238\"\u003e\n\n\u003cstrong data-end=\"1261\" data-start=\"1240\"\u003eLectura aleatoria (4K):\u003c\/strong\u003e Hasta 580,000 IOPS\u003c\/li\u003e\n\n\t\u003cli data-end=\"1322\" data-section-id=\"ddmj4n\" data-start=\"1283\"\u003e\n\n\u003cstrong data-end=\"1302\" data-start=\"1285\"\u003eEscritura aleatoria:\u003c\/strong\u003e Hasta 15,000 IOPS\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1327\" data-start=\"1324\"\u003e\n\u003ch3 data-end=\"1360\" data-section-id=\"zqh55d\" data-start=\"1329\"\u003e\u003cstrong data-end=\"1360\" data-start=\"1333\"\u003eDurabilidad y confiabilidad\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1553\" data-start=\"1361\"\u003e\n\n\t\u003cli data-end=\"1408\" data-section-id=\"65uwu8\" data-start=\"1361\"\u003e\n\n\u003cstrong data-end=\"1377\" data-start=\"1363\"\u003eDurabilidad:\u003c\/strong\u003e Hasta ~24.6 PBW (secuencial)\u003c\/li\u003e\n\n\t\u003cli data-end=\"1447\" data-section-id=\"1w4kgr6\" data-start=\"1409\"\u003e\n\n\u003cstrong data-end=\"1420\" data-start=\"1411\"\u003eDWPD:\u003c\/strong\u003e ~0.18 (cargas de trabajo aleatorias)\u003c\/li\u003e\n\n\t\u003cli data-end=\"1477\" data-section-id=\"dudf1e\" data-start=\"1448\"\u003e\n\n\u003cstrong data-end=\"1459\" data-start=\"1450\"\u003eMTBF:\u003c\/strong\u003e 2 millones de horas\u003c\/li\u003e\n\n\t\u003cli data-end=\"1553\" data-section-id=\"1v6jysd\" data-start=\"1478\"\u003e\n\n\u003cstrong data-end=\"1500\" data-start=\"1480\"\u003eProtección de datos:\u003c\/strong\u003e Protección contra pérdida de energía + Protección de datos de extremo a extremo\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1558\" data-start=\"1555\"\u003e\n\u003ch2 data-end=\"1608\" data-section-id=\"hd0bpc\" data-start=\"1560\"\u003e\u003cstrong data-end=\"1608\" data-start=\"1563\"\u003eCompatibilidad con Dell PowerEdge (bandeja DXD9H)\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp data-end=\"1709\" data-start=\"1610\"\u003eLa \u003cstrong data-end=\"1629\" data-start=\"1614\"\u003eDell 0DXD9H\u003c\/strong\u003e es un \u003cstrong data-end=\"1665\" data-start=\"1635\"\u003ecarrier universal SFF de 2.5\"\u003c\/strong\u003e utilizado en múltiples generaciones de PowerEdge.\u003c\/p\u003e\n\n\u003ch3 data-end=\"1742\" data-section-id=\"1jq305t\" data-start=\"1711\"\u003e\u003cstrong data-end=\"1742\" data-start=\"1715\"\u003e16ª Generación (Gen16)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1802\" data-start=\"1743\"\u003e\n\n\t\u003cli data-end=\"1759\" data-section-id=\"g84sa7\" data-start=\"1743\"\u003eR660, R660xs\u003c\/li\u003e\n\n\t\u003cli data-end=\"1776\" data-section-id=\"1y8dxtb\" data-start=\"1760\"\u003eR760, R760xs\u003c\/li\u003e\n\n\t\u003cli data-end=\"1793\" data-section-id=\"i2rt1\" data-start=\"1777\"\u003eR6615, R7615\u003c\/li\u003e\n\n\t\u003cli data-end=\"1802\" data-section-id=\"6m35an\" data-start=\"1794\"\u003eT560\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"1835\" data-section-id=\"x4ohht\" data-start=\"1804\"\u003e\u003cstrong data-end=\"1835\" data-start=\"1808\"\u003e15ª Generación (Gen15)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1899\" data-start=\"1836\"\u003e\n\n\t\u003cli data-end=\"1850\" data-section-id=\"1yztyed\" data-start=\"1836\"\u003eR450, R550\u003c\/li\u003e\n\n\t\u003cli data-end=\"1867\" data-section-id=\"1hgwm5r\" data-start=\"1851\"\u003eR650, R650xs\u003c\/li\u003e\n\n\t\u003cli data-end=\"1884\" data-section-id=\"1g2lvzj\" data-start=\"1868\"\u003eR750, R750xs\u003c\/li\u003e\n\n\t\u003cli data-end=\"1899\" data-section-id=\"hyjgbo\" data-start=\"1885\"\u003eR350, T550\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"1932\" data-section-id=\"7ic39t\" data-start=\"1901\"\u003e\u003cstrong data-end=\"1932\" data-start=\"1905\"\u003e14ª Generación (Gen14)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1989\" data-start=\"1933\"\u003e\n\n\t\u003cli data-end=\"1947\" data-section-id=\"196eizp\" data-start=\"1933\"\u003eR440, R540\u003c\/li\u003e\n\n\t\u003cli data-end=\"1970\" data-section-id=\"1x9u53o\" data-start=\"1948\"\u003eR640, R740, R740xd\u003c\/li\u003e\n\n\t\u003cli data-end=\"1979\" data-section-id=\"58mbgn\" data-start=\"1971\"\u003eR940\u003c\/li\u003e\n\n\t\u003cli data-end=\"1989\" data-section-id=\"1r2ogrv\" data-start=\"1980\"\u003eC6420\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"2048\" data-section-id=\"1p2ridg\" data-start=\"1991\"\u003e\u003cstrong data-end=\"2048\" data-start=\"1995\"\u003e17ª Generación (Gen17 – Sistemas limitados \/ más nuevos)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2107\" data-start=\"2049\"\u003e\n\n\t\u003cli data-end=\"2107\" data-section-id=\"1oxh81b\" data-start=\"2049\"\u003eR770 \u003cem data-end=\"2105\" data-start=\"2056\"\u003e(compatibilidad física en muchas configuraciones)\u003c\/em\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2112\" data-start=\"2109\"\u003e\n\u003ch3 data-end=\"2157\" data-section-id=\"icczf3\" data-start=\"2114\"\u003e\u003cstrong data-end=\"2157\" data-start=\"2118\"\u003eRequisitos críticos de compatibilidad\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2467\" data-start=\"2158\"\u003e\n\n\t\u003cli data-end=\"2231\" data-section-id=\"lpt41g\" data-start=\"2158\"\u003e\n\n\u003cstrong data-end=\"2174\" data-start=\"2160\"\u003eBackplane:\u003c\/strong\u003e DEBE ser \u003cstrong data-end=\"2199\" data-start=\"2183\"\u003ecompatible con NVMe\u003c\/strong\u003e (SAS\/SATA-only NO funcionará)\u003c\/li\u003e\n\n\t\u003cli data-end=\"2300\" data-section-id=\"wn30hn\" data-start=\"2232\"\u003e\n\n\u003cstrong data-end=\"2249\" data-start=\"2234\"\u003eBahías de disco:\u003c\/strong\u003e Busque \u003cstrong data-end=\"2298\" data-start=\"2259\"\u003eranuras etiquetadas como \"NVMe\" o \"Universal\"\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\t\u003cli data-end=\"2375\" data-section-id=\"11cwsvh\" data-start=\"2301\"\u003e\n\n\u003cstrong data-end=\"2315\" data-start=\"2303\"\u003eCableado:\u003c\/strong\u003e Se requiere cableado NVMe (SlimSAS \/ MCIO según el sistema)\u003c\/li\u003e\n\n\t\u003cli data-end=\"2467\" data-section-id=\"5kmhbb\" data-start=\"2376\"\u003e\n\n\u003cstrong data-end=\"2406\" data-start=\"2378\"\u003eSoporte RAID (Opcional):\u003c\/strong\u003e\n\t\u003cul data-end=\"2467\" data-start=\"2411\"\u003e\n\n\t\t\u003cli data-end=\"2467\" data-section-id=\"697xac\" data-start=\"2411\"\u003eDell PERC H755N \/ PERC 11\/12 (soporte NVMe trimodo)\u003c\/li\u003e\n\n\t\u003c\/ul\u003e\n\n\t\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2472\" data-start=\"2469\"\u003e\n\u003ch3 data-end=\"2494\" data-section-id=\"pm8yra\" data-start=\"2474\"\u003e\u003cstrong data-end=\"2494\" data-start=\"2478\"\u003eCaracterísticas clave\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2805\" data-start=\"2495\"\u003e\n\n\t\u003cli data-end=\"2569\" data-section-id=\"1p17c8y\" data-start=\"2495\"\u003e\n\n\u003cstrong data-end=\"2527\" data-start=\"2497\"\u003eAlmacenamiento QLC de alta capacidad:\u003c\/strong\u003e Ideal para entornos de datos a gran escala\u003c\/li\u003e\n\n\t\u003cli data-end=\"2653\" data-section-id=\"wjtk8y\" data-start=\"2570\"\u003e\n\n\u003cstrong data-end=\"2603\" data-start=\"2572\"\u003eRendimiento optimizado para lectura:\u003c\/strong\u003e Excelente para cargas de trabajo de análisis y transmisión\u003c\/li\u003e\n\n\t\u003cli data-end=\"2736\" data-section-id=\"txujxr\" data-start=\"2654\"\u003e\n\n\u003cstrong data-end=\"2683\" data-start=\"2656\"\u003eBandeja Dell OEM incluida:\u003c\/strong\u003e Garantiza un ajuste adecuado, flujo de aire y funcionalidad LED\u003c\/li\u003e\n\n\t\u003cli data-end=\"2805\" data-section-id=\"1ujwy2i\" data-start=\"2737\"\u003e\n\n\u003cstrong data-end=\"2766\" data-start=\"2739\"\u003eConfiabilidad empresarial:\u003c\/strong\u003e Diseñado para el funcionamiento 24\/7 del centro de datos\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2810\" data-start=\"2807\"\u003e\n\u003ch3 data-end=\"2837\" data-section-id=\"1hu8n6g\" data-start=\"2812\"\u003e\u003cstrong data-end=\"2837\" data-start=\"2816\"\u003eCasos de uso típicos\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2969\" data-start=\"2838\"\u003e\n\n\t\u003cli data-end=\"2867\" data-section-id=\"lavihj\" data-start=\"2838\"\u003eLagos de datos \/ almacenamiento \"tibio\"\u003c\/li\u003e\n\n\t\u003cli data-end=\"2903\" data-section-id=\"ytanrs\" data-start=\"2868\"\u003eRedes de distribución de contenido (CDN)\u003c\/li\u003e\n\n\t\u003cli data-end=\"2928\" data-section-id=\"bwfbvm\" data-start=\"2904\"\u003eBases de datos con gran volumen de lectura\u003c\/li\u003e\n\n\t\u003cli data-end=\"2969\" data-section-id=\"tuzzub\" data-start=\"2929\"\u003eReemplazo de HDD en servidores PowerEdge\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2974\" data-start=\"2971\"\u003e\n\u003ch3 data-end=\"2999\" data-section-id=\"1ws83tv\" data-start=\"2976\"\u003e\u003cstrong data-end=\"2999\" data-start=\"2980\"\u003eNotas importantes\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"3295\" data-start=\"3000\"\u003e\n\n\t\u003cli data-end=\"3082\" data-section-id=\"t93ijo\" data-start=\"3000\"\u003eEste es un SSD de \u003cstrong data-end=\"3035\" data-start=\"3012\"\u003electura intensiva (RI)\u003c\/strong\u003e — no apto para cargas de trabajo de escritura pesadas\u003c\/li\u003e\n\n\t\u003cli data-end=\"3135\" data-section-id=\"1lemy7a\" data-start=\"3083\"\u003eQLC NAND prioriza la \u003cstrong data-end=\"3133\" data-start=\"3106\"\u003ecapacidad sobre la durabilidad\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\t\u003cli data-end=\"3225\" data-section-id=\"18mkna9\" data-start=\"3136\"\u003eLa \u003cstrong data-end=\"3170\" data-start=\"3142\"\u003ebandeja DXD9H es mecánica\u003c\/strong\u003e — la funcionalidad NVMe depende de la configuración del servidor\u003c\/li\u003e\n\n\t\u003cli data-end=\"3295\" data-section-id=\"x1kt0g\" data-start=\"3226\"\u003eSiempre verifique que su sistema tenga \u003cstrong data-end=\"3293\" data-start=\"3258\"\u003ebackplane NVMe + cableado adecuado\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-end=\"3300\" data-start=\"3297\"\u003e\n\u003ch3 data-end=\"3317\" data-section-id=\"3l32ru\" data-start=\"3302\"\u003e\u003cstrong data-end=\"3317\" data-start=\"3306\"\u003eResumen\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"3638\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"3318\"\u003eEl Intel D5-P4326 de 15.36TB (SSDPE2NV153T8) con \u003cstrong data-end=\"3385\" data-start=\"3366\"\u003ebandeja Dell DXD9H\u003c\/strong\u003e es una solución NVMe potente y de alta capacidad para servidores Dell PowerEdge. Cuando se utiliza en sistemas configurados para NVMe, ofrece un excelente rendimiento de lectura, escalabilidad y eficiencia de costos, lo que lo convierte en una actualización ideal para los entornos de almacenamiento empresariales modernos.\u003c\/p\u003e\n","brand":"Intel","offers":[{"title":"Default Title","offer_id":48889967608064,"sku":"SSDPE2NV153T8-DELL-KIT-1","price":3372.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/c2dd94da-563d-58c2-b221-052aa226ac11.png?v=1782420441","url":"https:\/\/alotechparts.com\/es-br\/products\/intel-1536tb-nvme-u2-pcie-gen30-x4-ri-sff-25-ssd-d5-p4326-ssdpe2nv153t8-for-dell-poweredge-server-with-dell-tray-gen-16th-15th-14th","provider":"Alo Tech Solutions","version":"1.0","type":"link"}