{"product_id":"planet-igs-6329-8up2s4x-ip30-din-rail-industrial-l3-8-port-101001000t-8023bt-poe","title":"Planet IGS-6329-8UP2S4X IP30 DIN-rail Industrial L3 8-Port 10\/100\/1000T 802.3bt PoE","description":"\u003cp\u003eOutstanding 802.3bt PoE++ Solution for Heavy Industrial Environment\u003c\/p\u003e\n\u003cp\u003eWith EN 61000-6-2 and 61000-6-4 Heavy Industrial EMC, and railway EN 50121-4 certified design, and complying with the IEEE 802.3bt PoE++ technology, PLANET IGS-6329-8UP2S4X provides non-stop data communication and reliable PoE injection, even with noise interferences coming from the heavy industrial field applications. \u003c\/p\u003e\n\u003cp\u003eComplying with the IEEE 802.3bt Power over Ethernet Plus Plus technology, PLANET IGS-6329-8UP2S4X L3 Industrial Managed PoE++ Switch series features eight 10\/100\/1000BASE-T 802.3bt PoE++ ports with each port powering up to 95 watts, two 100\/1000\/2500BASE-X SFP and up to four 10G SFP+ ports interfaces in a rugged IP30 metal case for stable operation in heavy industrial demanding environments. It supports rich PoE operation modes including 90-watt 802.3bt type-4 PoE++ ports, 95-watt PoH (Power over HD-BASE-T) mode and 4-pair force mode to solve the incompatibility of non-standard 4-pair PoE PDs in the field. \u003c\/p\u003e\n\u003cp\u003eBeing able to operate under wide temperature range from -40 to 75 degrees C, the IGS-6329 PoE++ Switch series can be placed in almost any difficult environment. The IGS-6329 PoE++ Switch series also allows either DIN rail or wall mounting for efficient use of cabinet space. \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/edm_IGS-6329-8UP2S4X.jpg\" alt=\"\" width=\"1000\" height=\"400\"\u003e\u003c\/p\u003e\n\u003cp\u003e802.3bt PoE++ – 90~95-watt Power over 4-pair UTP Solution\u003c\/p\u003e\n\u003cp\u003eAs the IGS-6329 PoE++ Series adopts the IEEE 802.bt PoE++ standard and PoH technology, it is capable of sourcing up to 95 watts of power by using all the four pairs of standard Cat5e\/6 Ethernet cabling to deliver power and full-speed data to each remote PoE compliant powered device (PD). It possesses the power capacity that is triple than the conventional 802.3at PoE+ and is an ideal solution to satisfy the growing demand for higher power consuming network PDs, such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e　PoE PTZ speed dome cameras\u003c\/li\u003e\n\u003cli\u003e　Network devices \u003c\/li\u003e\n\u003cli\u003e　Thin clients\u003c\/li\u003e\n\u003cli\u003e　AIO (all-in-one) touch PCs, point of sale (POS) and information kiosks\u003c\/li\u003e\n\u003cli\u003e　Remote digital signage displays\u003c\/li\u003e\n\u003cli\u003e　PoE lightings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/IGS-6329-8UP2S4X-41.png\" alt=\"\" width=\"700\" height=\"297\"\u003e\u003c\/p\u003e\n\u003cp\u003e802.3bt PoE++ and Advanced PoE Power Output Mode Management\u003c\/p\u003e\n\u003cp\u003eTo meet the demand of various powered devices consuming stable PoE power, the IGS-6329 PoE++ Switch series provides five different PoE power output modes for selection.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e　90W 802.3bt PoE++ Power Output Mode\u003c\/li\u003e\n\u003cli\u003e　95W UPOE\/PoH Power Output Mode\u003c\/li\u003e\n\u003cli\u003e　60W Force Power Output Mode\u003c\/li\u003e\n\u003cli\u003e　30W End-span PoE Power Output Mode\u003c\/li\u003e\n\u003cli\u003e　30W Mid-span PoE Power Output Mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConvenient and Smart ONVIF Devices with Detection Feature\u003c\/p\u003e\n\u003cp\u003ePLANET has newly developed an awesome feature -- ONVIF Support -- which is specifically designed for co-operating with video IP surveillances. From the IGS-6329 PoE++ Switch series GUI, clients just need one click to search and show all of the ONVIF devices via network application. \u003c\/p\u003e\n\u003cp\u003eIn addition, clients can upload floor plans to the switch, allowing to locate surveillance devices for easier inspection and planning. Moreover, clients can get real-time surveillance’s information and online\/offline status, and also allows cameras PoE reboot control from GUI.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/IGS-6329-8UP2S4X-2.png\" alt=\"\" width=\"700\" height=\"371\"\u003e \u003c\/p\u003e\n\u003cp\u003eIntelligent Alive Check for Powered Device\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 PoE++ Series can be configured to monitor connected PD’s status in real time via ping action. Once the PD stops working and responding, the IGS-6329 PoE++ Series will recycle the PoE port power and bring the PD back to work. It also greatly enhances the reliability in that the PoE port will reset the PD power, thus reducing administrator’s management burden.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/IGS-6329-8UP2S4X-5.png\" alt=\"\" width=\"700\" height=\"152\"\u003e\u003c\/p\u003e\n\u003cp\u003ePoE Schedule for Energy Savings\u003c\/p\u003e\n\u003cp\u003eUnder the trend of energy savings worldwide and contributing to environmental protection on the Earth, the IGS-6329 PoE++ Series can effectively control the power supply besides its capability of giving high watts power. The built-in “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/Common_PoE-Schedule-for-Energy-Saving.png\" alt=\"\" width=\"700\" height=\"253\"\u003e\u003c\/p\u003e\n\u003cp\u003eScheduled Power Recycling\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 PoE++ Series allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specific time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/Common_Scheduled-Power-Recycling.png\" alt=\"\" width=\"700\" height=\"337\"\u003e\u003c\/p\u003e\n\u003cp\u003eLayer 3 Routing Support\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series enables the administrator to conveniently boost network efficiency by configuring Layer 3 IPv4\/IPv6 VLAN static routing manually, the RIP(Routing Information Protocol) or OSPF (Open Shortest Path First) settings automatically. The RIP can employ the hop count as a routing metric and prevent routing loops by implementing a limit on the number of hops allowed in a path from the source to a destination. The OSPF is an interior dynamic routing protocol for autonomous system based on link state. The protocol creates a database for link state by exchanging link states among Layer 3 switches, and then uses the Shortest Path First algorithm to generate a route table based on that database.\u003c\/p\u003e\n\u003cp\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a certain simple Ring network, the recovery time of data link can be as fast as 10ms.\u003c\/p\u003e\n\u003cp\u003eNetwork with Cybersecurity Helps Minimize Security Risks\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series comes with enhanced cybersecurity to fend off cyberthreats and cyberattacks. It supports SSHv2, TLSv1.2 and SNMPv3 protocols to provide strong protection against advanced threats. Served as a key point to transmit data and offering over 95-watt PoE output to customer's critical equipment in a business network, the cybersecurity feature of the IGS-6329 Series protects the switch management and enhances the security of the mission-critical network without any extra deployment cost and effort.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/IGS-6329-8UP2S4X-6.png\" alt=\"\" width=\"701\" height=\"219\"\u003e\u003c\/p\u003e\n\u003cp\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003c\/p\u003e\n\u003cp\u003eWith the supported Modbus TCP\/IP protocol, the IGS-6329 Series can easily integrate with SCADA systems, HMI systems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s operating information, port information, communication status, and DI and DO status, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\n\u003cp\u003e1588 Time Protocol for Industrial Computing Networks\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/IGS-6329-8UP2S4X-7.png\" alt=\"\" width=\"700\" height=\"435\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSMTP\/SNMP Trap Event Alert\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/IGS-6329-8UP2S4X-8.png\" alt=\"\" width=\"700\" height=\"280\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eEffective Alarm Alert for Better Protection\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time finding where the problem is. It will help to save time and human resource.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/IGS-6329-8UP2S4X-9.png\" alt=\"\" width=\"700\" height=\"375\"\u003e\u003c\/p\u003e\n\u003cp\u003eDigital Input and Digital Output for External Alarm\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series supports Digital Input and Digital Output on its front panel. This external alarm enables users to use Digital Input to detect and log external device status (such as door intrusion detector), and send event alarm to the administrators. The Digital Output could be used to alarm the administrators if the IGS-6329 Series’ port shows link down, link up or power failure.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/IGS-6329-8UP2S4X-10.png\" alt=\"\" width=\"700\" height=\"661\"\u003e\u003c\/p\u003e\n\u003cp\u003eRobust Layer 2 Features\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series can be programmed for advanced Layer 2 switch management functions such as dynamic port link aggregation, 802.1Q tagged VLAN, Q-in-Q VLAN, private VLAN, Multiple Spanning Tree Protocol (MSTP), Layer 2 to Layer 4 QoS, bandwidth control, IGMP snooping and MLD snooping. Via the aggregation of supporting ports, the IGS-6329 Series allows the operation of a high-speed trunk group that comes with multiple ports and supports fail-over as well.\u003c\/p\u003e\n\u003cp\u003eEfficient Management\u003c\/p\u003e\n\u003cp\u003eFor efficient management, the IGS-6329 Series is equipped with console, Web and SNMP management interfaces. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e　With the built-in Web-based management interface, it offers an easy-to-use, platform-independent management and configuration facility. \u003c\/li\u003e\n\u003cli\u003e　For text-based management, it can be accessed via Telnet and the console port. \u003c\/li\u003e\n\u003cli\u003e　For standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePowerful Network Security\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series offers comprehensive Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises 802.1X Port-based and MAC-based user and device authentication. With the private VLAN function, communication between edge ports can be prevented to ensure user privacy. \u003c\/p\u003e\n\u003cp\u003eAdvanced IP Network Protection\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series also provides DHCP Snooping, IP Source Guard and Dynamic ARP Inspection functions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp\u003eFlexible and Extendable 10Gb Ethernet Solution\u003c\/p\u003e\n\u003cp\u003e10Gbps Ethernet is a big leap in the evolution of Ethernet. Each of the 10G SFP+ slots in the IGS-6329-8UP2S4X supports multiple speed and 10GBASE-SR\/LR, 1000BASE-SX\/LX or 2500BASE-X. With its 4-port, 10Gbps  Ethernet link capability and additional 2-port 1G\/2.5Gbps  Ethernet link capability, the administrator now can flexibly choose the suitable SFP\/SFP+ transceiver according to the transmission distance or the transmission speed required to extend the network efficiently. The IGS-6329-8UP2S4X provides broad bandwidth and powerful processing capacity. \u003c\/p\u003e\n\u003cp\u003eIntelligent SFP Diagnosis Mechanism\u003c\/p\u003e\n\u003cp\u003eThe IGS-6329 Series supports SFP-DDM (digital diagnostic monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP and SFP+ transceivers, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/planet.com.tw\/storage\/products\/49496\/Common_Intelligent-SFP_SFP+-Diagnosis-Mechanism1.png\" alt=\"\" width=\"700\" height=\"351\"\u003e\u003c\/p\u003e\n\u003cp\u003ePhysical Port\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8 10\/100\/1000BASE-T Gigabit Ethernet RJ45 ports with 802.3bt PoE++ Injector function\u003c\/li\u003e\n\u003cli\u003e2 100\/1000\/2500BASE-X SFP slots for SFP type auto detection\u003c\/li\u003e\n\u003cli\u003e4 10GBASE-SR\/LR SFP+ slots, compatible with 1000BASE-X and 2500BASE-X SFP\u003c\/li\u003e\n\u003cli\u003eOne RJ45-to-RS232 console interface for basic management and setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIndustrial Hardened design \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual power input, redundant power with reverse polarity protection\n\u003cul\u003e\n\u003cli\u003eDC 48 to 54V input\u003c\/li\u003e\n\u003cli\u003eActive-active redundant power failure protection\u003c\/li\u003e\n\u003cli\u003eBackup of catastrophic power failure on one supply\u003c\/li\u003e\n\u003cli\u003eFault tolerance and resilience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN-rail and wall-mountable design\u003c\/li\u003e\n\u003cli\u003eIP30 aluminum case \u003c\/li\u003e\n\u003cli\u003eSupports ESD 6KV DC Ethernet protection\u003c\/li\u003e\n\u003cli\u003e-40 to 75 degrees C operating temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDigital Input and Digital Output\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Digital Input (DI)\u003c\/li\u003e\n\u003cli\u003e2 Digital Output (DO)\u003c\/li\u003e\n\u003cli\u003eIntegrate sensors into auto alarm system\u003c\/li\u003e\n\u003cli\u003eTransfer alarm to IP network via email and SNMP trap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e802.3bt Power over Ethernet \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with IEEE 802.3bt Power over Ethernet Plus Plus Type-4 PSE\u003c\/li\u003e\n\u003cli\u003eBackward compatible with IEEE 802.3at\/af PD device\u003c\/li\u003e\n\u003cli\u003eUp to 8 ports of IEEE 802.3af\/IEEE 802.3at\/IEEE 802.3bt PoE++ devices powered\u003c\/li\u003e\n\u003cli\u003eSupports PoE power up to 95 watts for each PoE port\u003c\/li\u003e\n\u003cli\u003eTotal of 360-watt PoE budget\u003c\/li\u003e\n\u003cli\u003eAuto detects powered device (PD)\u003c\/li\u003e\n\u003cli\u003eCircuit protection prevents power interference between ports\u003c\/li\u003e\n\u003cli\u003eRemote power feeding up to 100m\u003c\/li\u003e\n\u003cli\u003ePoE management features\n\u003cul\u003e\n\u003cli\u003eTotal PoE power budget control\u003c\/li\u003e\n\u003cli\u003ePer port PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE admin-mode control \u003c\/li\u003e\n\u003cli\u003ePoE port power feeding priority\u003c\/li\u003e\n\u003cli\u003ePer PoE port power limit\u003c\/li\u003e\n\u003cli\u003ePD classification detection\u003c\/li\u003e\n\u003cli\u003ePoE extend mode control to support power feeding up to a distance of up to 160 meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntelligent PoE features\u003c\/li\u003e\n\u003cli\u003eTemperature threshold control\u003c\/li\u003e\n\u003cli\u003ePoE usage threshold control\u003c\/li\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLayer 3 IP Routing Features\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP dynamic routing protocol supports RIPv2, OSPFv2 and OSPFv3\u003c\/li\u003e\n\u003cli\u003eIPv4\/IPv6 hardware static routing\u003c\/li\u003e\n\u003cli\u003eRouting interface provides per VLAN routing mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLayer 2 Features\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance of Store-and-Forward architecture, and runt\/CRC filtering eliminates erroneous packets to optimize the network bandwidth\u003c\/li\u003e\n\u003cli\u003eStorm Control support\n\u003cul\u003e\n\u003cli\u003eBroadcast\/Multicast\/Unicast\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports VLAN\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eSupports provider bridging (IEEE 802.1ad VLAN Q-in-Q) \u003c\/li\u003e\n\u003cli\u003ePrivate VLAN Edge (PVE)\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eMAC-based VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003eGVRP (GARP VLAN Registration Protocol)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports Spanning Tree Protocol\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Guard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports Link Aggregation\n\u003cul\u003e\n\u003cli\u003e802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003cli\u003eMaximum 4 trunk groups with 4 ports per trunk group \u003c\/li\u003e\n\u003cli\u003eUp to 80Gbps bandwidth (duplex mode) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProvides port mirror (many-to-1)\u003c\/li\u003e\n\u003cli\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port \u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP)\u003c\/li\u003e\n\u003cli\u003eCompatible with Cisco uni-directional link detection(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices\u003c\/li\u003e\n\u003cli\u003eSupports G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/li\u003e\n\u003cli\u003eIEEE 1588v2 PTP (Precision Time Protocol) transparent clock mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eQuality of Service\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIngress Shaper and Egress Rate Limit per port bandwidth control\u003c\/li\u003e\n\u003cli\u003e8 priority queues on all switch ports\u003c\/li\u003e\n\u003cli\u003eTraffic classification\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1p CoS\u003c\/li\u003e\n\u003cli\u003eIP TOS\/DSCP\/IP precedence\u003c\/li\u003e\n\u003cli\u003eIP TCP\/UDP port number\u003c\/li\u003e\n\u003cli\u003eTypical network application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003c\/li\u003e\n\u003cli\u003eSupports QoS and In\/Out bandwidth control on each port\u003c\/li\u003e\n\u003cli\u003eTraffic-policing  on the switch port\u003c\/li\u003e\n\u003cli\u003eDSCP remarking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMulticast\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports IPv4 IGMP snooping v1, v2 and v3\u003c\/li\u003e\n\u003cli\u003eSupports IPv6 MLD snooping v1 and v2\u003c\/li\u003e\n\u003cli\u003eQuerier mode support\u003c\/li\u003e\n\u003cli\u003eIPv4 IGMP snooping port filtering\u003c\/li\u003e\n\u003cli\u003eIPv6 MLD snooping port filtering\u003c\/li\u003e\n\u003cli\u003eMVR (Multicast VLAN Registration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSecurity\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuthentication\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1X Port-based\/MAC-based network access authentication\u003c\/li\u003e\n\u003cli\u003eBuilt-in RADIUS client to cooperate with the RADIUS servers\u003c\/li\u003e\n\u003cli\u003eTACACS+ login users access authentication\u003c\/li\u003e\n\u003cli\u003eRADIUS\/TACACS+ users access authentication\u003c\/li\u003e\n\u003cli\u003eGuest VLAN assigns clients to a restricted VLAN with limited services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess Control Lit\n\u003cul\u003e\n\u003cli\u003eIP-based Access Control List (ACL)\u003c\/li\u003e\n\u003cli\u003eMAC-based Access Control List\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSource MAC\/IP address binding\u003c\/li\u003e\n\u003cli\u003eDHCP snooping to filter distrusted DHCP messages\u003c\/li\u003e\n\u003cli\u003eDynamic ARP Inspection discards ARP packets with invalid MAC address to IP address binding\u003c\/li\u003e\n\u003cli\u003eIP Source Guard prevents IP spoofing attacks\u003c\/li\u003e\n\u003cli\u003eIP address access management to prevent unauthorized intruder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSwitch Management\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 and IPv6 dual stack management\u003c\/li\u003e\n\u003cli\u003eSwitch Management Interfaces\n\u003cul\u003e\n\u003cli\u003eConsole and Telnet Command Line Interface \u003c\/li\u003e\n\u003cli\u003eHTTP web switch management\u003c\/li\u003e\n\u003cli\u003eSNMP v1 and v2c switch management\u003c\/li\u003e\n\u003cli\u003eSSHv2, TLSv1.2 and SNMPv3 secure access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSNMP Management\n\u003cul\u003e\n\u003cli\u003eFour RMON groups (history, statistics, alarms, and events) \u003c\/li\u003e\n\u003cli\u003eSNMP trap for interface Link Up and Link Down notification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIPv6 IP address\/NTP\/DNS management\u003c\/li\u003e\n\u003cli\u003eBuilt-in Trivial File Transfer Protocol (TFTP) client\u003c\/li\u003e\n\u003cli\u003eBOOTP and DHCP for IP address assignment\u003c\/li\u003e\n\u003cli\u003eSystem Maintenance\n\u003cul\u003e\n\u003cli\u003eFirmware upload\/download via HTTP\u003c\/li\u003e\n\u003cli\u003eReset button for system reboot or reset to factory default\u003c\/li\u003e\n\u003cli\u003eDual images\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDHCP Relay and Option 82\u003c\/li\u003e\n\u003cli\u003eDHCP Server\u003c\/li\u003e\n\u003cli\u003eUser Privilege levels control\u003c\/li\u003e\n\u003cli\u003eNetwork Time Protocol (NTP)\u003c\/li\u003e\n\u003cli\u003eNetwork Diagnostic\n\u003cul\u003e\n\u003cli\u003eSFP-DDM (Digital Diagnostic Monitor)\u003c\/li\u003e\n\u003cli\u003eCable diagnostic technology provides the mechanism to detect and report potential cabling issues\u003c\/li\u003e\n\u003cli\u003eICMPv6\/ICMPv4 remote ping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSMTP, Syslog and SNMP trap remote alarm\u003c\/li\u003e\n\u003cli\u003eSystem Log\u003c\/li\u003e\n\u003cli\u003ePLANET Smart Discovery Utility for deployment management\u003c\/li\u003e\n\u003cli\u003ePLANET UNI-NMS (Universal Network Management) and Smart Discovery Utility for deployment management\u003c\/li\u003e\n\u003cli\u003eProvides ONVIF for co-operating with PLANET video IP surveillances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eHardware Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e8 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP Ports\u003c\/td\u003e\n\u003ctd\u003e2 1000BASE-SX\/LX\/BX SFP slot interfaces (Port-9 and Port-10)\u003cbr\u003eCompatible with 100BASE-FX and 2500BASE-X SFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ Ports\u003c\/td\u003e\n\u003ctd\u003e4 10GBASE-SR\/LR SFP+ slot interfaces (Port-11 to Port-14)\u003cbr\u003eCompatible with 1000BASE-X and 2500BASE-X SFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Injector Ports\u003c\/td\u003e\n\u003ctd\u003e8 ports with 802.3bt PoE++ injector function with Port-1 to Port-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45-to-RS232 serial port (115200, 8, N, 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRemovable 6-pin terminal block for power input\u003cbr\u003e　Pin 1\/2 for Power 1, Pin 3\/4 for fault alarm, Pin 5\/6 for Power 2\u003cbr\u003eRemovable 6-pin terminal block for DI\/DO interface\u003cbr\u003e　Pin 1\/2 for DI 1 \u0026amp; 2, Pin 3\/4 for DO 1 \u0026amp; 2, Pin 5\/6 for GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eOne relay output for power failure. Alarm relay current carry ability: 1A @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input (DI)\u003c\/td\u003e\n\u003ctd\u003e2 digital inputs:\u003cbr\u003e　Level 0: -24~2.1V (±0.1V)\u003cbr\u003e　Level 1: 2.1~24V (±0.1V)\u003cbr\u003e　Input load to 24V DC, 10mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output (DO)\u003c\/td\u003e\n\u003ctd\u003e2 digital outputs:\u003cbr\u003e　Open collector to 24VDC, 100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP30 aluminum case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e76 x 135 x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1,619g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eDual DC 48~54V, 8A max.\u003cbr\u003e(\u0026gt;52V DC for 802.3bt PoE++ output recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 12.4 watts\/42.3BTU@54V DC input (System on)\u003cbr\u003eMax. 430 watts\/1467.2BTU@54V DC input (Full loading with 802.3bt PoE++ function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003eAir 8KV DC\u003cbr\u003eContact 6KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e4KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicator\u003c\/td\u003e\n\u003ctd\u003eSystem:\u003cbr\u003e　Power 1 (Green), Power 2 (Green), Alarm (Red)\u003cbr\u003e　Ring (Green), Ring Owner (Green), DIDO (Red)\u003cbr\u003ePer 10\/100\/1000T RJ45 PoE++ Port:\u003cbr\u003e　1000Mbps LNK\/ACT (Green)\u003cbr\u003e　10\/100Mbps LNK\/ACT (Amber)\u003cbr\u003e　802.3bt PoE++-in-use x 1 (Green)\u003cbr\u003e　802.3at\/af PoE-in-use x 1 (Amber)\u003cbr\u003ePer SFP Interface:\u003cbr\u003e　1G\/2.5G LNK\/ACT (Green)\u003cbr\u003e　100 LNK\/ACT (Amber)\u003cbr\u003ePer SFP+ Port:\u003cbr\u003e　10Gbps LNK\/ACT (Green)\u003cbr\u003e　1Gbps LNK\/ACT (Amber)\u003cbr\u003ePoE Usage:\u003cbr\u003e　90W, 180W, 270W, 360W (Amber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitching Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e106Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput (packet per second)\u003c\/td\u003e\n\u003ctd\u003e78.87Mpps@ 64 bytes packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Table\u003c\/td\u003e\n\u003ctd\u003e32K entries, automatic source address learning and aging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e32Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e10Kbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDRAM\u003c\/td\u003e\n\u003ctd\u003e512Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e64Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3x pause frame for full-duplex\u003cbr\u003eBack pressure for half-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePower Over Ethernet\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3bt PoE++ Type-4 PSE\u003cbr\u003eBackward compatible with 802.3at PoE+ PSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Power Supply Type\u003c\/td\u003e\n\u003ctd\u003e802.3bt\u003cbr\u003eUPOE\/POH\u003cbr\u003eEnd-span\u003cbr\u003eMid-span\u003cbr\u003eForce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Power Output\u003c\/td\u003e\n\u003ctd\u003e802.3bt PoE++\u003cbr\u003e　Per port 52V~54V DC (depending on the power supply), max. 90 watts\u003cbr\u003eUPoE(PoH)\u003cbr\u003e　Per port 52V~54V DC (depending on the power supply), max. 95 watts\u003cbr\u003eIEEE 802.3at Standard\u003cbr\u003e　Per port 52V~54V DC (depending on the power supply), max. 36 watts\u003cbr\u003eForce\u003cbr\u003e　Per port 52V~54V DC (depending on the power supply), max. 60 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Pin Assignment\u003c\/td\u003e\n\u003ctd\u003eEnd-span: 1\/2(-), 3\/6(+)\u003cbr\u003eMid-span: 4\/5(+), 7\/8(-)\u003cbr\u003e802.3bt\/UPoE: 1\/2(-), 3\/6(+),4\/5(+), 7\/8(-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003eSingle power input: 240W maximum (depending on power input)\u003cbr\u003e　Dual power input: 360W maximum (depending on power input)\u003cbr\u003e※Dual power input must be the same as DC voltage, like dual 54V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Ability PD @ 12.5 watts\u003c\/td\u003e\n\u003ctd\u003e8 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Ability PD @ 25 watts\u003c\/td\u003e\n\u003ctd\u003e8 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Ability PD @ 51 watts\u003c\/td\u003e\n\u003ctd\u003e6 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Ability PD @ 71 watts\u003c\/td\u003e\n\u003ctd\u003e4 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePoE Management Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive PoE device alive detects\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Power Recycle\u003c\/td\u003e\n\u003ctd\u003eYes, daily or predeinded schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Schedule\u003c\/td\u003e\n\u003ctd\u003e4 schedule profiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Extend Mode\u003c\/td\u003e\n\u003ctd\u003eYes, max. 160 to 200 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE System Management\u003c\/td\u003e\n\u003ctd\u003eSystem PoE Admin control\u003cbr\u003eTotal PoE power budget control\u003cbr\u003eAuto power input and PoE budget control\u003cbr\u003ePoE Legacy mode\u003cbr\u003eOver-temperature threshold alarm\u003cbr\u003ePoE usage threshold alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Port Management\u003c\/td\u003e\n\u003ctd\u003ePort Enable\/Disable\/Schedule\u003cbr\u003ePoE mode control\u003cbr\u003e　802.3bt\u003cbr\u003e　UPoE\u003cbr\u003e　802.3at End-span\u003cbr\u003e　802.3at Mid-span\u003cbr\u003eForce mode\u003cbr\u003ePort Priority\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 2 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003ePort disable\/enable\u003cbr\u003eAuto-negotiation 10\/100\/1000Mbps full and half duplex mode selection\u003cbr\u003eFlow control disable\/enable\u003cbr\u003ePort link capability control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Status\u003c\/td\u003e\n\u003ctd\u003eDisplay each port’s speed duplex mode, link status, flow control status,\u003cbr\u003eauto negotiation status, trunk status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd\u003eTX\/RX\/both\u003cbr\u003eMany-to-1 monitor\u003cbr\u003eSupports up to 5 sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Q tagged VLAN\u003cbr\u003eIEEE 802.1ad Q-in-Q tunneling\u003cbr\u003ePrivate VLAN Edge (PVE)\u003cbr\u003eMAC-based VLAN\u003cbr\u003eProtocol-based VLAN\u003cbr\u003eVoice VLAN\u003cbr\u003eMVR (Multicast VLAN Registration)\u003cbr\u003eGVRP\u003cbr\u003eUp to 4K VLAN groups, out of 4095 VLAN IDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ad LACP\/static trunk\u003cbr\u003eSupports 3 trunk groups with 4 ports per trunk group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv4 IGMP (v1\/v2\/v3) snooping\u003cbr\u003eIPv4 IGMP querier mode support\u003cbr\u003eSupports 255 IGMP groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv6 MLD (v1\/v2) snooping,\u003cbr\u003eIPv6 MLD querier mode support\u003cbr\u003eSupports 255 MLD groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth Control\u003c\/td\u003e\n\u003ctd\u003ePer port bandwidth control\u003cbr\u003e　Ingress: 500Kb~1000Mbps\u003cbr\u003e　Egress: 500Kb~1000Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRing\u003c\/td\u003e\n\u003ctd\u003eSupports ERPS, and complies with ITU-T G.8032\u003cbr\u003eRecovery time \u0026lt; 10ms\u003cbr\u003eSupports Major ring and sub-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 PTP(Precision Time Protocol)\u003cbr\u003e　Peer-to-peer transparent clock\u003cbr\u003e　End-to-end transparent clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQoS\u003c\/td\u003e\n\u003ctd\u003eTraffic classification based, strict priority and WRR\u003cbr\u003e8-level priority for switching\u003cbr\u003e　Port number\u003cbr\u003e　802.1p priority\u003cbr\u003e　802.1Q VLAN tag\u003cbr\u003e　DSCP\/TOS field in IP packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 3 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Interfaces\u003c\/td\u003e\n\u003ctd\u003eMax. 128 VLAN interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Table\u003c\/td\u003e\n\u003ctd\u003eMax. 128 routing entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eIPv4 hardware static routing\u003cbr\u003eIPv6 hardware static routing\u003cbr\u003eRIPv2 dynamic routing\u003cbr\u003eIPv4 OSPFv2 dynamic routing\u003cbr\u003eIPv6 OSPFv3 dynamic routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSecurity Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Control List\u003c\/td\u003e\n\u003ctd\u003eIP-based ACL\/MAC-based ACL\u003cbr\u003eACL based on:\u003cbr\u003e　MAC Address\u003cbr\u003e　IP Address\u003cbr\u003e　Ethertype\u003cbr\u003e　Protocol Type\u003cbr\u003e　VLAN ID\u003cbr\u003e　DSCP\u003cbr\u003e　802.1p Priority\u003cbr\u003eUp to 256 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003ePort security\u003cbr\u003eIP source guard\u003cbr\u003eDynamic ARP inspection\u003cbr\u003eCommand line authority control based on user level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAAA\u003c\/td\u003e\n\u003ctd\u003eRADIUS client\u003cbr\u003eTACACS+ client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Access Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x port-based network access control\u003cbr\u003eMAC-based authentication\u003cbr\u003eLocal\/RADIUS authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eManagement Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eConsole; Telnet; Web browser; SNMP v1, v2c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eSSHv2, TLSv1.2, SNMPv3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Management\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade by HTTP protocol through Ethernet network\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eRemote Syslog\u003cbr\u003eSystem log\u003cbr\u003eLLDP protocol\u003cbr\u003eNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003cbr\u003ePLANET CloudViewer app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Management\u003c\/td\u003e\n\u003ctd\u003eRemote Syslog\u003cbr\u003eSystem log\u003cbr\u003eSMTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eONVIF\u003c\/td\u003e\n\u003ctd\u003eONVIF device discovery\u003cbr\u003eONVIF device monitoring\u003cbr\u003eFloor Map\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC 1213 MIB-II\u003cbr\u003eRFC 1493 Bridge MIB\u003cbr\u003eRFC 1643 Ethernet MIB\u003cbr\u003eRFC 2863 Interface MIB\u003cbr\u003eRFC 2665 Ether-Like MIB\u003cbr\u003eRFC 2819 RMON MIB (Group 1, 2, 3 and 9)\u003cbr\u003eRFC 2737 Entity MIB\u003cbr\u003eRFC 2618 RADIUS Client MIB\u003cbr\u003eRFC 2863 IF-MIB\u003cbr\u003eRFC 2933 IGMP-STD-MIB\u003cbr\u003eRFC 3411 SNMP-Frameworks-MIB\u003cbr\u003eRFC 4292 IP Forward MIB\u003cbr\u003eRFC 4293 IP MIB\u003cbr\u003eRFC 4836 MAU-MIB\u003cbr\u003eIEEE 802.1X PAE\u003cbr\u003eLLDP\u003cbr\u003eMAU-MIB\u003cbr\u003ePower over Ethernet MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandards Conformance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A\u003cbr\u003eCE:\u003cbr\u003e　EN 55032 , EN 55035\u003cbr\u003e　EN 61000-6-2, EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRailway\u003c\/td\u003e\n\u003ctd\u003eEN50121-4, EN 50121-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability Testing\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-32 (free fall)\u003cbr\u003eIEC 60068-2-27 (shock)\u003cbr\u003eIEC 60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 10BASE-T\u003cbr\u003eIEEE 802.3u 100BASE-TX\/100BASE-FX\u003cbr\u003eIEEE 802.3z Gigabit SX\/LX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE 802.3ae 10Gb\/s Ethernet\u003cbr\u003eIEEE 802.3x flow control and back pressure\u003cbr\u003eIEEE 802.3ad port trunk with LACP\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE 802.1p Class of Service\u003cbr\u003eIEEE 802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1X Port Authentication Network Control\u003cbr\u003eIEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3af Power over Ethernet\u003cbr\u003eIEEE 802.3at Power over Ethernet Plus\u003cbr\u003eIEEE 802.3bt Power over Ethernet Plus Plus\u003cbr\u003eIEEE 802.3ah OAM\u003cbr\u003eIEEE 802.1ag Connectivity Fault Management (CFM)\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 793 TFTP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eRFC 3376 IGMP v3\u003cbr\u003eRFC 2710 MLD v1\u003cbr\u003eRFC 3810 MLD v2\u003cbr\u003eRFC 2328 OSPF v2\u003cbr\u003eITU-T G.8032 ERPS Ring\u003cbr\u003eITU-T Y.1731 Performance Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEnvironment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ~ 75 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ~ 85 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":48892938748160,"sku":"IGS-6329-8UP2S4X","price":2128.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/box_IGS-6329-8UP2S4X.jpg?v=1782490919","url":"https:\/\/alotechparts.com\/en-mx\/products\/planet-igs-6329-8up2s4x-ip30-din-rail-industrial-l3-8-port-101001000t-8023bt-poe","provider":"Alo Tech Solutions","version":"1.0","type":"link"}